BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

174 related articles for article (PubMed ID: 6881097)

  • 1. Evaluation of the accuracy of the diff3/50 with a cell by cell comparison.
    Cembrowski GS; Wilson MK; Adelmeyer SG; Chang CK
    Am J Clin Pathol; 1983 Sep; 80(3):333-41. PubMed ID: 6881097
    [TBL] [Abstract][Full Text] [Related]  

  • 2. An evaluation of the Coulter Diff3 50, an automated differential leukocyte counter.
    Galloway SJ; Rossiter GJ; Pidcock ME
    Pathology; 1985 Oct; 17(4):563-7. PubMed ID: 3938005
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Reference values for automated cytochemical differential count of leukocytes in children 0-16 years old: comparison with manually obtained counts from Wright-stained smears.
    Cranendonk E; van Gennip AH; Abeling NG; Behrendt H; Hart AA
    J Clin Chem Clin Biochem; 1985 Oct; 23(10):663-7. PubMed ID: 2415666
    [TBL] [Abstract][Full Text] [Related]  

  • 4. The white blood cell differential. Evaluation of rapid impression scanning versus the routine manual count.
    Arkin CF; Medeiros LJ; Pevzner LZ; Guertin BP; Kobos PJ; Phelps JW; Smith SJ
    Am J Clin Pathol; 1987 May; 87(5):628-32. PubMed ID: 3578137
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Sysmex SE-9000 hematology analyzer: performance evaluation on leukocyte differential counts using an NCCLS H20-A protocol. National Committee for Clinical Laboratory Standards.
    Buttarello M; Bulian P; Temporin V; Rizzotti P
    Am J Clin Pathol; 1997 Dec; 108(6):674-86. PubMed ID: 9384450
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Automated differential leucocyte counters: an evaluation of the Hemalog D and A comparison with the Hematrak. I. Principles of operation; reproducibility and accuracy on normal blood samples.
    Bain BJ; Neill PJ; Scott D; Scott TJ; Innis MD
    Pathology; 1980 Jan; 12(1):83-100. PubMed ID: 7375149
    [TBL] [Abstract][Full Text] [Related]  

  • 7. An automatic leukocyte analyzer. Validity of its results.
    Arkin CF; Sherry MA; Gough AG; Copeland BE
    Am J Clin Pathol; 1977 Feb; 67(2):159-69. PubMed ID: 836621
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Comparison of the Cytodiff flow cytometric leucocyte differential count system with the Sysmex XE-2100 and Beckman Coulter UniCel DxH 800.
    Park BG; Park CJ; Kim S; Yoon CH; Kim DH; Jang S; Chi HS
    Int J Lab Hematol; 2012 Dec; 34(6):584-93. PubMed ID: 22709133
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Comparison of automated differential blood cell counts from Abbott Sapphire, Siemens Advia 120, Beckman Coulter DxH 800, and Sysmex XE-2100 in normal and pathologic samples.
    Meintker L; Ringwald J; Rauh M; Krause SW
    Am J Clin Pathol; 2013 May; 139(5):641-50. PubMed ID: 23596116
    [TBL] [Abstract][Full Text] [Related]  

  • 10. An evaluation of the Coulter VCS differential counter.
    Barnard DF; Barnard SA; Carter AB; Patterson KG; Yardumian A; Machin SJ
    Clin Lab Haematol; 1989; 11(3):255-66. PubMed ID: 2591156
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Short-term biological variation of differential count in healthy subjects in a South Asian population.
    Gupta AK; Kunnumbrath A; Tayal SG; Mehan A; Sahay R; Kumar U; Jeladharan R; Anthony ML; Singh N; Chandra H; Chowdhury N
    Scand J Clin Lab Invest; 2020 Dec; 80(8):654-658. PubMed ID: 33016776
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Biological variation of the leukocyte differential count quantities.
    Dot D; Miró J; Fuentes-Arderiu X
    Scand J Clin Lab Invest; 1992 Nov; 52(7):607-11. PubMed ID: 1455152
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Differential white cell counting on the Coulter Counter Model S Plus IV (three population) and the Technicon H6000; a comparison by simple and multiple regression.
    Clarke PT; Henthorn JS; England JM
    Clin Lab Haematol; 1985; 7(4):335-51. PubMed ID: 3830531
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Canine differential leukocyte counting with the CellaVision DM96Vision, Sysmex XT-2000iV, and Advia 2120 hematology analyzers and a manual method.
    Tvedten HW; Lilliehöök IE
    Vet Clin Pathol; 2011 Sep; 40(3):324-39. PubMed ID: 21884185
    [TBL] [Abstract][Full Text] [Related]  

  • 15. The LARC automatic white blood cell analyzer.
    Megla GK
    Acta Cytol; 1973; 17(1):3-14. PubMed ID: 4119231
    [No Abstract]   [Full Text] [Related]  

  • 16. Evaluation of the Coulter S-Plus IV three-part differential as a screening tool in a tertiary care hospital.
    Miers MK; Fogo AB; Federspiel CF; McAllister NW; Phillips PA; Cousar JB
    Am J Clin Pathol; 1987 Jun; 87(6):745-51. PubMed ID: 3591747
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Quality control in a manual and an automated leukocyte differential count.
    Takubo T; Tatsumi N
    Southeast Asian J Trop Med Public Health; 1999; 30 Suppl 3():66-74. PubMed ID: 10926263
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The Hemalog D white cell differential system.
    Mansberg HP; Saunders AM; Groner W
    J Histochem Cytochem; 1974 Jul; 22(7):711-24. PubMed ID: 4137312
    [No Abstract]   [Full Text] [Related]  

  • 19. Interlaboratory variation of leukocyte differential counts: results from the Finnish proficiency testing programme in haematological morphology, 1974-1977.
    Rajamäki A
    Scand J Clin Lab Invest; 1979 Nov; 39(7):613-7. PubMed ID: 531488
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Laboratory and clinical evaluation of white blood cell differential counts. Comparison of the Coulter VCS, Technicon H-1, and 800-cell manual method.
    Swaim WR
    Am J Clin Pathol; 1991 Mar; 95(3):381-8. PubMed ID: 1996547
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.