These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

109 related articles for article (PubMed ID: 6888688)

  • 21. Evaluation of the tissue damage of porcine ovaries after bipolar drilling under transvaginal hydrolaparoscopy--an in vitro experiment.
    Ma CH; Yang S; Qiao J; Yang Y; Liu P
    Gynecol Endocrinol; 2010 Jul; 26(7):549-53. PubMed ID: 20184485
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Tissue thermal damage caused by bipolar forceps can be reduced with a combination of plastic and metal.
    Remorgida V
    Surg Endosc; 1998 Jul; 12(7):936-9. PubMed ID: 9632865
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Reductions in blood loss with use of a bipolar sealer for hemostasis in primary total knee arthroplasty.
    Marulanda GA; Ragland PS; Seyler TM; Mont MA
    Surg Technol Int; 2005; 14():281-6. PubMed ID: 16525984
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Radio frequency leakage current from unipolar laparoscopic electrocoagulators.
    DiNovo JA
    J Reprod Med; 1983 Sep; 28(9):565-75. PubMed ID: 6226780
    [TBL] [Abstract][Full Text] [Related]  

  • 25. In vivo effect of 5 French bipolar and monopolar electrosurgical probes on the porcine bladder.
    Tucker RD; Kramolowsky EV; Platz CE
    Urol Res; 1990; 18(4):291-4. PubMed ID: 2219593
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Randomized controlled study of injury in the canine right colon from simultaneous biopsy and coagulation with different hot biopsy forceps.
    Savides TJ; See JA; Jensen DM; Jutabha R; Machicado GA; Hirabayashi K
    Gastrointest Endosc; 1995 Dec; 42(6):573-8. PubMed ID: 8674930
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Endoscopic bipolar electrocoagulation in upper gastrointestinal bleeding.
    Hajiro K; Yamamoto H; Matsui H; Tsujimura D; Yamamoto T; Hirooka T; Todo A
    Endoscopy; 1984 Jan; 16(1):6-9. PubMed ID: 6607833
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Comparison of the effect of monopolar and bipolar cauterization on skeletonized, dissected internal thoracic arteries.
    Yoshida H; Wu MH; Kouchi Y; Onuki Y; Shi Q; Sauvage LR
    J Thorac Cardiovasc Surg; 1995 Aug; 110(2):504-10. PubMed ID: 7637368
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Morphofunctional peculiarities of the effects of electric coagulator on thyroid tissue.
    Aliev ZO; Egiev VN; Shurygin SN; Il'ina EV
    Bull Exp Biol Med; 2005 Sep; 140(3):352-5. PubMed ID: 16307057
    [TBL] [Abstract][Full Text] [Related]  

  • 30. A randomized comparison of a new flexible bipolar hemostasis forceps designed principally for NOTES versus a conventional surgical laparoscopic bipolar forceps for intra-abdominal vessel sealing in a porcine model.
    Park PO; Long GL; Bergström M; Cunningham C; Vakharia OJ; Bakos GJ; Bally KR; Rothstein RI; Swain CP
    Gastrointest Endosc; 2010 Apr; 71(4):835-41. PubMed ID: 19942215
    [TBL] [Abstract][Full Text] [Related]  

  • 31. New application of bipolar coagulation in laparoscopic surgery.
    McKernan JB; Stuto A; Champion JK
    Surg Laparosc Endosc; 1996 Oct; 6(5):335-40. PubMed ID: 8890416
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Bipolar electrosurgical devices.
    Tucker RD; Hollenhorst MJ
    Endosc Surg Allied Technol; 1993 Apr; 1(2):110-3. PubMed ID: 8055299
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Endovascular electrocoagulation with a bipolar electrode and alternating current: a follow-up study in dogs.
    Brunelle F; Kunstlinger F; Quillard J
    Radiology; 1983 Aug; 148(2):413-5. PubMed ID: 6867333
    [TBL] [Abstract][Full Text] [Related]  

  • 34. [Hemostasis and technology. Energy. Development of new technologies].
    Balagué C
    Cir Esp; 2009 Jun; 85 Suppl 1():15-22. PubMed ID: 19589405
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Transcatheter electrocoagulation: experimental evaluation of the anode.
    Thompson WM; McAlister DS; Miller M; Pizzo SV; Jackson DC; Johnsrude IS
    Invest Radiol; 1979; 14(1):41-7. PubMed ID: 478795
    [TBL] [Abstract][Full Text] [Related]  

  • 36. A new technique for monopolar haemostasis in inferior turbinate surgery.
    Ross SK; Jaiswal V; Sama A
    Clin Otolaryngol; 2007 Apr; 32(2):147-8. PubMed ID: 17403249
    [No Abstract]   [Full Text] [Related]  

  • 37. A blinded in vitro comparison of five sets of bipolar diathermy forceps.
    Nadig SK; Back GW; Uppal S; Coatesworth AP
    Clin Otolaryngol Allied Sci; 2004 Dec; 29(6):721-4. PubMed ID: 15533167
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Endoscopic band ligation for control of nonvariceal upper GI hemorrhage: comparison with bipolar electrocoagulation.
    Matsui S; Kamisako T; Kudo M; Inoue R
    Gastrointest Endosc; 2002 Feb; 55(2):214-8. PubMed ID: 11818925
    [TBL] [Abstract][Full Text] [Related]  

  • 39. A novel monoshaft bipolar cautery for use in endoscopic intracranial surgery. A short technical note.
    Nagasaka T; Tsugeno M; Ikeda H; Okamoto T; Inao S; Wakabayashi T
    Clin Neurol Neurosurg; 2011 Oct; 113(8):607-11. PubMed ID: 21511394
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Hemostasis with a bipolar sealer during surgical correction of adolescent idiopathic scoliosis.
    Mankin KP; Moore CA; Miller LE; Block JE
    J Spinal Disord Tech; 2012 Jul; 25(5):259-63. PubMed ID: 21964452
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.