These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

116 related articles for article (PubMed ID: 689061)

  • 21. Measurement of ascending aortic flow patterns in man.
    Uther JB; Peterson KL; Shabetai R; Braunwald E
    J Appl Physiol; 1973 Apr; 34(4):513-8. PubMed ID: 4698610
    [No Abstract]   [Full Text] [Related]  

  • 22. Evaluation of transit-time and electromagnetic flow measurement in a chronically instrumented nonhuman primate model.
    Koenig SC; Reister CA; Schaub J; Swope RD; Ewert D; Fanton JW
    J Invest Surg; 1996; 9(6):455-61. PubMed ID: 8981219
    [TBL] [Abstract][Full Text] [Related]  

  • 23. A catheter flow probe for measurement of left ventricular source parameters.
    Min BG; Kostis JB; Welkowitz W; Fich S
    IEEE Trans Biomed Eng; 1979 Sep; 26(9):509-12. PubMed ID: 161547
    [No Abstract]   [Full Text] [Related]  

  • 24. Doppler and electromagnetic comparisons of instantaneous aortic flow characteristics in primates.
    Spencer KT; Lang RM; Neumann A; Borow KM; Shroff SG
    Circ Res; 1991 May; 68(5):1369-77. PubMed ID: 1826864
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Chronic measurement of cardiac output in conscious mice.
    Janssen B; Debets J; Leenders P; Smits J
    Am J Physiol Regul Integr Comp Physiol; 2002 Mar; 282(3):R928-35. PubMed ID: 11832416
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Hemodynamics.
    Taylor MG
    Annu Rev Physiol; 1973; 35():87-116. PubMed ID: 4575165
    [No Abstract]   [Full Text] [Related]  

  • 27. Methods and value of pulsatile blood flow measurements in man.
    Greenfield JC
    Cardiovasc Clin; 1975; 6(3):371-83. PubMed ID: 126111
    [No Abstract]   [Full Text] [Related]  

  • 28. Aortic blood velocity measurement in healthy adults using a simple ultrasound technique.
    Mowat DH; Haites NE; Rawles JM
    Cardiovasc Res; 1983 Feb; 17(2):75-80. PubMed ID: 6871901
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Assessment of left ventricular function by indices derived from aortic flow velocity.
    Kolettis M; Jenkins BS; Webb-Peploe MM
    Br Heart J; 1976 Jan; 38(1):18-31. PubMed ID: 1252292
    [TBL] [Abstract][Full Text] [Related]  

  • 30. [Hemodynamic evaluation with catheter-tip electromagnetic flow probe after open heart surgery (author's transl)].
    Kotoda K; Fukushima K; Kiyokawa T; Kimura S; Harada M; Hasegawa T
    Nihon Kyobu Geka Gakkai Zasshi; 1980 Mar; 28(3):385-92. PubMed ID: 6445924
    [No Abstract]   [Full Text] [Related]  

  • 31. Simultaneous assessment of cardiac output with pulsed Doppler and electromagnetic flowmeters during cardiac stimulation.
    Grohs JG; Huber S; Raberger G
    J Pharmacol Toxicol Methods; 1993 Sep; 30(1):33-8. PubMed ID: 8241544
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Evaluation of a new catheter-mounted electromagnetic velocity sensor during cardiac catheterization.
    Nichols WW; Pepine CJ; Conti CR; Christie LG; Feldman RL
    Cathet Cardiovasc Diagn; 1980; 6(1):97-113. PubMed ID: 6988082
    [No Abstract]   [Full Text] [Related]  

  • 33. Left ventricular output derived from the time-derivative and phase velocities of the aortic pressure wave.
    McDonald DA; Nichols WW
    Med Biol Eng; 1973 Nov; 11(6):678-90. PubMed ID: 4274625
    [No Abstract]   [Full Text] [Related]  

  • 34. A comparison of empiric contractile indices in intact dogs.
    Patterson RE; Kent BB; Peirce EC
    Cardiology; 1972; 57(5):277-94. PubMed ID: 4651781
    [No Abstract]   [Full Text] [Related]  

  • 35. A monitor for the continuous assessment of left ventricular performance after open-heart operations.
    Farnsworth AE; Angerpointner TA; Lewis GJ; Bourne PR; Williams BT
    Ann Thorac Surg; 1977 Feb; 23(2):169-72. PubMed ID: 138401
    [TBL] [Abstract][Full Text] [Related]  

  • 36. [Use of an electromagnetic flowmeter in heart operations].
    Meisner H; Messmer K; Sebening F; Struck E; Klinner W
    Thoraxchir Vask Chir; 1967 Dec; 15(6):626-33. PubMed ID: 5240631
    [No Abstract]   [Full Text] [Related]  

  • 37. Correlation of peak aortic and carotid flow acceleration during coronary occlusion in conscious baboons.
    Chimoskey JE; Flanagan WJ; Huntsman LL; Gams E; Rushmer RF
    Clin Sci Mol Med; 1975 Apr; 48(4):243-6. PubMed ID: 1126118
    [TBL] [Abstract][Full Text] [Related]  

  • 38. [Continuous monitoring system of cardiac performance (part 2) (author's transl)].
    Tsuda H; Muteki T; Yamada T; Takeuchi M; Takagi T
    Masui; 1979 Mar; 28(3):235-44. PubMed ID: 439366
    [No Abstract]   [Full Text] [Related]  

  • 39. Doppler measurements of aortic blood flow velocity and acceleration: load-independent indexes of left ventricular performance?
    Gardin JM
    Am J Cardiol; 1989 Oct; 64(14):935-6. PubMed ID: 2679032
    [No Abstract]   [Full Text] [Related]  

  • 40. [Technical characteristics of an electromagnetic transducer of aortic flow, with reduced structure].
    Dalla Valle R; Guttullo D; Vacca G
    Boll Soc Ital Biol Sper; 1979 Sep; 55(17):1700-6. PubMed ID: 162123
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.