BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

149 related articles for article (PubMed ID: 6897083)

  • 21. Diagnosis of pregnancy in marmosets: hemagglutination inhibition test and radioimmunoassay for urinary chorionic gonadotropin.
    Hodgen GD; Wolfe LG; Ogden JD; Adams MR; Descalzi CC; Hildebrand DF
    Lab Anim Sci; 1976 Apr; 26(2 Pt l):224-9. PubMed ID: 818446
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Monoclonal antibody pregnancy test.
    Bluestein D; van Wolkenten R; Eugley C; Anderson R
    J Fam Pract; 1988 Sep; 27(3):252-3. PubMed ID: 3047305
    [No Abstract]   [Full Text] [Related]  

  • 23. Interference by heterophilic antibodies in immunoassays: wrong increase of myoglobin values.
    Bonetti A; Monica C; Bonaguri C; Gnocchi C; Russo A; Battistelli L; Musiari L; Pastori P; Novarini A
    Acta Biomed; 2008 Aug; 79(2):140-3. PubMed ID: 18788511
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Heterophyle antibodies causing false positive radio-immunoassay results. A case report.
    Smitz J; Foulon W; Heip J; Naaktgeboren N; Van Steirteghem A
    Ann Biol Clin (Paris); 1987; 45(4):453-5. PubMed ID: 2823647
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Eliminating heterophilic antibody interference for ferritin detection using Olympus F(ab')2 based reagent.
    Grouzmann E; Dayer N; Bain C; Neville CM; McCusker MD; Wang RY
    Clin Lab; 2008; 54(9-10):355-7. PubMed ID: 19097493
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Invalidity from nonparallelism in a radioimmunoassay for erythropoietin accounted for by human serum antibodies to rabbit IgG.
    Deacon R; Hellebostad M; Gaines Das RE; Milne A; Rowley M; Cotes PM
    Exp Hematol; 1993 Dec; 21(13):1680-5. PubMed ID: 8243569
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Pregnancy tests: evaluation of current status.
    Rippey JH
    Crit Rev Clin Lab Sci; 1984; 19(4):353-9. PubMed ID: 6373143
    [TBL] [Abstract][Full Text] [Related]  

  • 28. ACOG. Committee opinion: number 278, November 2002. Avoiding inappropriate clinical decisions based on false-positive human chorionic gonadotropin test results.
    Committee on Gynecologic Practice, The American College of Obstetricians and Gynecologists
    Obstet Gynecol; 2002 Nov; 100(5 Pt 1):1057-9. PubMed ID: 12434782
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Use of the radioreceptor assay for human chorionic gonadotropin in the diagnosis of ectopic pregnancy.
    Pelosi MA
    Surg Gynecol Obstet; 1981 Feb; 152(2):149-52. PubMed ID: 7209756
    [TBL] [Abstract][Full Text] [Related]  

  • 30. A method for routine detection of heterophile antibody interference in the Abbott AxSYM hCG assay.
    Jones GR; Giannopoulos P
    Pathology; 2004 Aug; 36(4):364-6. PubMed ID: 15370140
    [No Abstract]   [Full Text] [Related]  

  • 31. Easy fix for clinical laboratories for the false-positive defect with the Abbott AxSym total beta-hCG test.
    Cole LA; Khanlian SA
    Clin Biochem; 2004 May; 37(5):344-9. PubMed ID: 15087248
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Spurious elevation of serum PSA after curative treatment for prostate cancer: clinical consequences and the role of heterophilic antibodies.
    Anderson CB; Pyle AL; Woodworth A; Cookson MS; Smith JA; Barocas DA
    Prostate Cancer Prostatic Dis; 2012 Jun; 15(2):182-8. PubMed ID: 22105412
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Heterophile antibodies and false-positive assays for human chorionic gonadotropin.
    Letterie GS; Rose S; Miyazawa K
    Am J Obstet Gynecol; 1988 Dec; 159(6):1598-9. PubMed ID: 3207138
    [No Abstract]   [Full Text] [Related]  

  • 34. Early urinary pregnancy testing. Correlation with serum beta-HCG radioimmunoassay.
    Corson SL; Batzer FR
    J Reprod Med; 1982 Dec; 27(12):725-8. PubMed ID: 7161752
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Immunoassay interference: a relatively rare but still important problem.
    Diamandis EP
    Clin Biochem; 2004 May; 37(5):331-2. PubMed ID: 15087246
    [No Abstract]   [Full Text] [Related]  

  • 36. Repeated spurious elevation of serum prostate-specific antigen values solved by chemiluminescence analysis: A possible interference by heterophilic antibodies.
    Domínguez A; Bayó M; Muñoz-Rodríguez J; Bellido JA; Abascal-Junquera JM; Hannaoui N; Banús JM
    Korean J Urol; 2015 Nov; 56(11):785-7. PubMed ID: 26568798
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Canine heterophilic antibodies as a source of false-positive B-type natriuretic peptide sandwich ELISA results.
    Solter PF; Oyama MA; Sisson DD
    Vet Clin Pathol; 2008 Mar; 37(1):86-95. PubMed ID: 18366550
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Immunoglobulin interference in serum follicle-stimulating hormone assays: autoimmune and heterophilic antibody interference.
    Webster R; Fahie-Wilson M; Barker P; Chatterjee VK; Halsall DJ
    Ann Clin Biochem; 2010 Jul; 47(Pt 4):386-9. PubMed ID: 20511373
    [TBL] [Abstract][Full Text] [Related]  

  • 39. [A patient showing increased T3 and T4 levels due to ALP-interfering substances and heterophilic antibody].
    Kawakita S
    Rinsho Byori; 1996 Sep; 44(9):899-902. PubMed ID: 8911078
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Human heterophilic antibodies display specificity for murine IgG subclasses.
    Bjerner J; Olsen KH; Børmer OP; Nustad K
    Clin Biochem; 2005 May; 38(5):465-72. PubMed ID: 15820778
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.