BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

49 related articles for article (PubMed ID: 6917854)

  • 1. Reliability of the MS-2 system in detecting methicillin-resistant Staphylococcus aureus.
    Boyce JM; White RL; Bonner MC; Lockwood WR
    J Clin Microbiol; 1982 Feb; 15(2):220-5. PubMed ID: 6917854
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Misclassification of susceptible strains of Staphylococcus aureus as methicillin-resistant S. aureus By a rapid automated susceptibility testing system.
    Ribeiro J; Vieira FD; King T; D'Arezzo JB; Boyce JM
    J Clin Microbiol; 1999 May; 37(5):1619-20. PubMed ID: 10203540
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Evaluation of the Cathra inoculating device for susceptibility testing of methicillin-susceptible and methicillin-resistant Staphylococcus aureus strains.
    Boyce JM; Bonner MC; Lockwood WR
    Antimicrob Agents Chemother; 1982 Nov; 22(5):901-2. PubMed ID: 6924824
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Susceptibility testing of multidrug-resistant Staphylococcus aureus with the Sceptor microdilution system.
    Blair HC; Cleary TJ
    J Clin Microbiol; 1983 Jul; 18(1):194-6. PubMed ID: 6885987
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Concurrent comparability of automated systems and commercially prepared microdilution trays for susceptibility testing.
    Hansen SL; Freedy PK
    J Clin Microbiol; 1983 May; 17(5):878-86. PubMed ID: 6863508
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Successful use of broth microdilution in susceptibility tests for methicillin-resistant (heteroresistant) staphylococci.
    Thornsberry C; McDougal LK
    J Clin Microbiol; 1983 Nov; 18(5):1084-91. PubMed ID: 6643661
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Interlaboratory variation of antibiograms of methicillin-resistant and methicillin-susceptible Staphylococcus aureus strains with conventional and commercial testing systems.
    Aldridge KE; Janney A; Sanders CV; Marier RL
    J Clin Microbiol; 1983 Nov; 18(5):1226-36. PubMed ID: 6605976
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Reliability of in vitro susceptibility tests for detecting coagulase-negative staphylococcal resistance to penicillinase-resistant semisynthetic penicillins.
    Lowy FD; Chang DS; Aning V; Williams S; Szilagyi G
    J Clin Microbiol; 1983 Nov; 18(5):1122-6. PubMed ID: 6605974
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Detection of methicillin-resistant Staphylococcus aureus by microdilution and disk elution susceptibility systems.
    Boyce JM; Lytle LS; Walsh DA
    J Clin Microbiol; 1984 Dec; 20(6):1068-75. PubMed ID: 6569873
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Reevaluation of the ability of the standardized disk diffusion test to detect methicillin-resistant strains of Staphylococcus aureus.
    Boyce JM
    J Clin Microbiol; 1984 Jun; 19(6):813-7. PubMed ID: 6565707
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Early detection of oxacillin-resistant staphylococcal strains with hypertonic broth diluent for microdilution panels.
    Dillon LK; Howe SE
    J Clin Microbiol; 1984 Apr; 19(4):473-6. PubMed ID: 6562124
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Detection of oxacillin-resistant staphylococci by the AutoMicrobic system.
    Stotler RW; Meyer MC
    J Clin Microbiol; 1983 Nov; 18(5):1205-11. PubMed ID: 6557116
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Variation in the abilities of automated, commercial, and reference methods to detect methicillin-resistant (heteroresistant) Staphylococcus aureus.
    Hansen SL; Freedy PK
    J Clin Microbiol; 1984 Sep; 20(3):494-9. PubMed ID: 6490833
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Evaluation of the automicrobic system for detection of resistance of Staphylococcus aureus to methicillin.
    Woolfrey BF; Lally RT; Ederer MN
    J Clin Microbiol; 1984 Apr; 19(4):464-7. PubMed ID: 6425359
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Rapid recognition of methicillin-resistant Staphylococcus aureus by use of automated test systems.
    Jorgensen JH; Redding J; Johnson JE; Holloway V; Almeida RJ
    J Clin Microbiol; 1984 Sep; 20(3):430-3. PubMed ID: 6386859
    [TBL] [Abstract][Full Text] [Related]  

  • 16. False-susceptible results from the MS-2 system used for testing resistant Pseudomonas aeruginosa against two third-generation cephalosporins, moxalactam and cefotaxime.
    Stone LL; Jungkind DL
    J Clin Microbiol; 1983 Aug; 18(2):389-94. PubMed ID: 6311875
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Addition of NaCl to MS-2 system clinical cuvettes for combined salt tolerance and susceptibility testing for group D streptococci.
    Nice EG; Stone LL; Fenton JJ
    J Clin Microbiol; 1985 Feb; 21(2):247-8. PubMed ID: 3919055
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Autobac susceptibility testing of methicillin-resistant Staphylococcus aureus isolated in an Australian hospital.
    Putland RA; Guinness MD
    J Clin Microbiol; 1985 Nov; 22(5):822-7. PubMed ID: 3850902
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Use of the Autobac system for detection of methicillin-resistant Staphylococcus aureus.
    de Rautlin de la Roy Y; Chevalier-Burbaud E; Pannetier S; Souchaud F
    J Clin Microbiol; 1985 Sep; 22(3):467-9. PubMed ID: 3850094
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Effect of the source of Mueller-Hinton agar and resistance frequency on the detection of methicillin-resistant Staphylococcus aureus.
    Hindler JA; Inderlied CB
    J Clin Microbiol; 1985 Feb; 21(2):205-10. PubMed ID: 3844408
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 3.