These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

183 related articles for article (PubMed ID: 6937150)

  • 1. Automatic ventilation with the Ayre's T-piece. A modification of the Nuffield Series 200 ventilator for neonatal and paediatric use.
    Newton NI; Hillman KM; Varley JG
    Anaesthesia; 1981 Jan; 36(1):22-36. PubMed ID: 6937150
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Modified interface between pediatric ventilator and Ayre's T-piece for use in neonates.
    el-Attar AM
    Middle East J Anaesthesiol; 1996 Feb; 13(4):395-403. PubMed ID: 8713634
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Increasing the length of the expiratory limb of the Ayre's T-piece: implications for remote mechanical ventilation in infants and young children.
    Jackson E; Tan S; Yarwood G; Sury MR
    Br J Anaesth; 1994 Aug; 73(2):154-6. PubMed ID: 7917727
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Volume-Targeted Ventilation in the Neonate: Benchmarking Ventilators on an Active Lung Model.
    Krieger TJ; Wald M
    Pediatr Crit Care Med; 2017 Mar; 18(3):241-248. PubMed ID: 28121833
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [A study of the parameters of the delivered tidal volume. Ventilation on a lung model using the CICERO anesthetic ventilator].
    Schirmer U; Villwock J; Fösel T; Schreiber M; Goertz A; Georgieff M
    Anaesthesist; 1992 Dec; 41(12):785-9. PubMed ID: 1489078
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Do new anesthesia ventilators deliver small tidal volumes accurately during volume-controlled ventilation?
    Bachiller PR; McDonough JM; Feldman JM
    Anesth Analg; 2008 May; 106(5):1392-400, table of contents. PubMed ID: 18420850
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A new device for mechanical ventilation of infants and small children.
    Damia G; Elena A; Croci M; Solca M
    Intensive Care World; 1995 Mar; 12(1):9-11. PubMed ID: 10150390
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A method of controlled ventilation with a circle-absorber breathing system.
    Jeal DE
    Br J Anaesth; 1977 Mar; 49(3):273-6. PubMed ID: 269740
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Bench performance of ventilators during simulated paediatric ventilation.
    Park MA; Freebairn RC; Gomersall CD
    Anaesth Intensive Care; 2013 May; 41(3):349-58. PubMed ID: 23659397
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Comparison of actual tidal volume in neonatal lung model volume control ventilation using three ventilators.
    Toyama H; Endo Y; Ejima Y; Matsubara M; Kurosawa S
    Anaesth Intensive Care; 2011 Jul; 39(4):599-606. PubMed ID: 21823376
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Performance of neonatal ventilators in volume targeted ventilation mode.
    Sharma A; Milner AD; Greenough A
    Acta Paediatr; 2007 Feb; 96(2):176-80. PubMed ID: 17429900
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Performance of Leak Compensation in All-Age ICU Ventilators During Volume-Targeted Neonatal Ventilation: A Lung Model Study.
    Itagaki T; Bennett DJ; Chenelle CT; Fisher DF; Kacmarek RM
    Respir Care; 2017 Jan; 62(1):10-21. PubMed ID: 27879380
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Artificial ventilation in infants and young children using a new ventilator with the T-piece.
    Kuwabara S; McCaughey TJ
    Can Anaesth Soc J; 1966 Nov; 13(6):576-84. PubMed ID: 5225586
    [No Abstract]   [Full Text] [Related]  

  • 14. Volume-guaranteed ventilation.
    Riley C; Pilcher J
    Neonatal Netw; 2003; 22(2):17-22. PubMed ID: 12696722
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Mechanical ventilation with air-oxygen mixtures during total intravenous anaesthesia. An evaluation of the Penlon Nuffield Series 400 ventilator.
    Davey AJ; Riley B
    Anaesthesia; 1983 Apr; 38(4):355-60. PubMed ID: 6573858
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The Newton valve revisited: an in-vitro study of ventilator circuit dead space.
    Wongprasartsuk P; Mason DG
    Paediatr Anaesth; 2000; 10(4):389-93. PubMed ID: 10886695
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Neonatal and adult ICU ventilators to provide ventilation in neonates, infants, and children: a bench model study.
    Vignaux L; Piquilloud L; Tourneux P; Jolliet P; Rimensberger PC
    Respir Care; 2014 Oct; 59(10):1463-75. PubMed ID: 25118306
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Effects of Leak Compensation on Patient-Ventilator Synchrony During Premature/Neonatal Invasive and Noninvasive Ventilation: A Lung Model Study.
    Itagaki T; Chenelle CT; Bennett DJ; Fisher DF; Kacmarek RM
    Respir Care; 2017 Jan; 62(1):22-33. PubMed ID: 27651525
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Positive-negative pressure ventilation with a modified Ayre's T-piece.
    EGER EI; HAMILTON WK
    Anesthesiology; 1958; 19(5):611-8. PubMed ID: 13571635
    [No Abstract]   [Full Text] [Related]  

  • 20. Ventilator-delivered mask ventilation compared with three standard methods of mask ventilation in a manikin model.
    Tracy MB; Klimek J; Coughtrey H; Shingde V; Ponnampalam G; Hinder M; Maheshwari R; Tracy SK
    Arch Dis Child Fetal Neonatal Ed; 2011 May; 96(3):F201-5. PubMed ID: 20530107
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.