These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

198 related articles for article (PubMed ID: 6941598)

  • 1. Thin fluid-filled catheters for more accurate determination of pressures and their time derivatives.
    Lomholt N; Bille-Brahe NE; Andersen HR; Djuurhus JC; Bredgaard M
    Acta Chir Scand Suppl; 1980; 502():27-32. PubMed ID: 6941598
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Quantification and simulation of fluid-filled catheter/transducer systems.
    Taylor BC; Ellis DM; Drew JM
    Med Instrum; 1986; 20(3):123-9. PubMed ID: 3724585
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Technology and application of ultraminiature catheter pressure transducers.
    Zimmer HG; Millar HD
    Can J Cardiol; 1998 Oct; 14(10):1259-66. PubMed ID: 9852939
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Experimental evaluation of a new transducer tipped catheter.
    Kar S; Drury JK; Tokioka H; Meerbaum S; Corday E
    Indian Heart J; 1989; 41(4):213-20. PubMed ID: 2807355
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Systemic error during measurement of dp/dt using conventional heart catheters and their correction].
    Hampel H; Siegert M; Jarofke R
    Z Kardiol; 1975 Jan; 64(1):83-91. PubMed ID: 1114866
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Registration and evaluation of blood pressure curves of the pulmonary artery with reference to various causes of error].
    Weller W
    Z Kardiol; 1975 Jan; 64(1):68-83. PubMed ID: 1114865
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Experience with the Millar PC-350 catheter-tip pressure transducer.
    Nichols WW; Walker WE
    Biomed Eng; 1974 Feb; 9(2):58-60. PubMed ID: 4815560
    [No Abstract]   [Full Text] [Related]  

  • 8. Sweep-frequency marker generator for blood pressure transducer testing.
    Lee AS
    J Clin Eng; 1983; 8(3):248-52. PubMed ID: 10263340
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A new "transducer-tipped" fiber optic catheter for measuring intramuscular pressures.
    Crenshaw AG; Styf JR; Mubarak SJ; Hargens AR
    J Orthop Res; 1990 May; 8(3):464-8. PubMed ID: 2324863
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [The development of the side hole type fiber optic catheter transducer for intracardiac pressure measurement (author's transl)].
    Matsumoto H; Saigusa M; Saito K; Mizoi K
    Iyodenshi To Seitai Kogaku; 1977 Dec; 15(7):480-6. PubMed ID: 609141
    [No Abstract]   [Full Text] [Related]  

  • 11. Aneurysm sac pressure monitoring: effect of technique on interpretation of measurements.
    Hinnen JW; Visser MJ; van Bockel JH
    Eur J Vasc Endovasc Surg; 2005 Mar; 29(3):233-8. PubMed ID: 15694793
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A catheter-tip capacitance pressure transducer.
    Delpy DT
    Biomed Eng; 1975 Jan; 10(1):16-20. PubMed ID: 1125352
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Evaluation of catheter-manometer systems for adequate intravascular blood pressure measurements in small animals.
    Idvall J; Aronsen KF; Lindström K; Ulmsten U
    Res Exp Med (Berl); 1977 Sep; 171(2):101-10. PubMed ID: 928971
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Measurement of arterial pressure using catheter-transducer systems. Improvement using the Accudynamic.
    Allan MW; Gray WM; Asbury AJ
    Br J Anaesth; 1988 Mar; 60(4):413-8. PubMed ID: 3355737
    [TBL] [Abstract][Full Text] [Related]  

  • 15. An evaluation of the BD RT2000 reusable transducer system for invasive blood pressure monitoring.
    Ng KG; Chua TK; Tan C; Cole J; Quickel G
    Blood Press Monit; 2007 Feb; 12(1):35-43. PubMed ID: 17303986
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Monitoring acute compartment pressures with the S.T.I.C. catheter.
    McDermott AG; Marble AE; Yabsley RH
    Clin Orthop Relat Res; 1984 Nov; (190):192-8. PubMed ID: 6488631
    [TBL] [Abstract][Full Text] [Related]  

  • 17. The fidelity and dynamic response of fluid-filled catheter systems for direct measurement of lumbar cerebrospinal fluid pressure.
    Kumar M; Werner E; Murray MJ
    J Clin Monit; 1993 Nov; 9(5):314-20. PubMed ID: 8106883
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Extramembranous placement of an air-coupled vs. transducer-tipped intrauterine pressure catheter.
    Sciscione AC; Duhl A; Pollock MA; Hoffman MK; Rhee A; Colmorgen GH
    J Reprod Med; 2005 Aug; 50(8):578-84. PubMed ID: 16220762
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Development of a new catheter-tip pressure transducer.
    Kinefuchi Y; Fukuyama H; Suzuki T; Kanazawa M; Takiguchi M
    Tokai J Exp Clin Med; 1999 Oct; 24(3):85-92. PubMed ID: 10733155
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Time-dependent pressure distortion in a catheter-transducer system: correction by fast flush.
    Promonet C; Anglade D; Menaouar A; Bayat S; Durand M; Eberhard A; Grimbert FA
    Anesthesiology; 2000 Jan; 92(1):208-18. PubMed ID: 10638918
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.