149 related articles for article (PubMed ID: 6962725)
1. The detection of deep venous thrombosis by impedance plethysmography in hip surgery patients.
Gray DH; Mackie CE
Aust N Z J Surg; 1982 Dec; 52(6):569-72. PubMed ID: 6962725
[TBL] [Abstract][Full Text] [Related]
2. Distribution and occlusiveness of thrombi in patients with surveillance detected deep vein thrombosis after hip surgery.
Ascani A; Radicchia S; Parise P; Nenci GG; Agnelli G
Thromb Haemost; 1996 Feb; 75(2):239-41. PubMed ID: 8815567
[TBL] [Abstract][Full Text] [Related]
3. Impedance plethysmography: the relationship between venous filling and sensitivity and specificity for proximal vein thrombosis.
Hull R; Taylor DW; Hirsh J; Sackett DL; Powers P; Turpie AG; Walker I
Circulation; 1978 Nov; 58(5):898-902. PubMed ID: 699257
[TBL] [Abstract][Full Text] [Related]
4. Cuff-impedance phlebography and 125I fibrinogen scanning versus roentgenographic phlebography for diagnosis of thrombophlebitis following hip surgery. A preliminary report.
Harris WH; Athanasoulis C; Waltman AC; Salzman EW
J Bone Joint Surg Am; 1976 Oct; 58(7):939-44. PubMed ID: 977625
[TBL] [Abstract][Full Text] [Related]
5. Impedance plethysmography using the occlusive cuff technique in the diagnosis of venous thrombosis.
Hull R; van Aken WG; Hirsh J; Gallus AS; Hoicka G; Turpie AG; Walker I; Gent M
Circulation; 1976 Apr; 53(4):696-700. PubMed ID: 1253393
[TBL] [Abstract][Full Text] [Related]
6. Venous thrombosis in patients who have undergone major hip or knee surgery: detection with compression US and impedance plethysmography.
Ginsberg JS; Caco CC; Brill-Edwards PA; Panju AA; Bona R; Demers CM; Tuters LM; Nugent P; McGinnis J; Grant BM
Radiology; 1991 Dec; 181(3):651-4. PubMed ID: 1947076
[TBL] [Abstract][Full Text] [Related]
7. Combined use of leg scanning and impedance plethysmography in suspected venous thrombosis. An alternative to venography.
Hull R; Hirsh J; Sackett DL; Powers P; Turpie AG; Walker I
N Engl J Med; 1977 Jun; 296(26):1497-500. PubMed ID: 865529
[TBL] [Abstract][Full Text] [Related]
8. Extent of leg vein thrombosis determined by impedance and 125-I fibrinogen.
Hume M; Kurlakose TX; Jamieson J; Turner RH
Am J Surg; 1975 Apr; 129(4):455-8. PubMed ID: 1124845
[TBL] [Abstract][Full Text] [Related]
9. Impedance plethysmography. A noninvasive screening method to detect deep-vein thrombosis.
Ward PE; Bradley FB; Brown JG; Kernohan WG; McGivern RC; Mollan RA
Clin Orthop Relat Res; 1989 Nov; (248):195-9. PubMed ID: 2805479
[TBL] [Abstract][Full Text] [Related]
10. Screening for lower extremity deep venous thrombosis. An improved plethysmographic and Doppler approach.
Lepore TJ; Savran J; Van De Water J; Harrower HW; Yablonski M
Am J Surg; 1978 Apr; 135(4):529-34. PubMed ID: 637200
[TBL] [Abstract][Full Text] [Related]
11. An evaluation of impedance plethysmography and 125I-fibrinogen leg scanning in patients following hip surgery.
Cruickshank MK; Levine MN; Hirsh J; Turpie AG; Powers P; Jay R; Gent M
Thromb Haemost; 1989 Nov; 62(3):830-4. PubMed ID: 2595657
[TBL] [Abstract][Full Text] [Related]
12. Impedance plethysmography: correlation with contrast venography.
Benedict KT; Wheeler HB; Patwardhan NA
Radiology; 1977 Dec; 125(3):695-9. PubMed ID: 928695
[TBL] [Abstract][Full Text] [Related]
13. B-mode ultrasound scanning in the detection of proximal venous thrombosis after total hip replacement.
Woolson ST; McCrory DW; Walter JF; Maloney WJ; Watt JM; Cahill PD
J Bone Joint Surg Am; 1990 Aug; 72(7):983-7. PubMed ID: 2200790
[TBL] [Abstract][Full Text] [Related]
14. Features of thrombi and diagnostic accuracy of impedance plethysmography in symptomatic and asymptomatic deep vein thrombosis.
Agnelli G; Cosmi B; Radicchia S; Veschi F; Boschetti E; Lupattelli L; Rinonapoli E; Nenci GG
Thromb Haemost; 1993 Aug; 70(2):266-9. PubMed ID: 8236133
[TBL] [Abstract][Full Text] [Related]
15. Diagnosis of femoropopliteal venous thrombosis: comparison of duplex sonography and plethysmography.
Rosner NH; Doris PE
AJR Am J Roentgenol; 1988 Mar; 150(3):623-7. PubMed ID: 3277352
[TBL] [Abstract][Full Text] [Related]
16. Occlusive impedance plethysmography. A noninvasive method of diagnosis of proximal deep vein thrombosis.
Toy PT; Schrier SL
West J Med; 1978 Aug; 129(2):89-93. PubMed ID: 567893
[TBL] [Abstract][Full Text] [Related]
17. Impedance plethysmography. A screening procedure to detect deep-vein thrombosis.
Brown JG; Ward PE; Wilkinson AJ; Mollan RA
J Bone Joint Surg Br; 1987 Mar; 69(2):264-7. PubMed ID: 3818758
[TBL] [Abstract][Full Text] [Related]
18. Limitations of impedance phlebography for diagnosis of venous thrombosis.
Steer ML; Spotnitz AJ; Cohen SI; Paulin S; Salzman EW
Arch Surg; 1973 Jan; 106(1):44-8. PubMed ID: 4682104
[No Abstract] [Full Text] [Related]
19. Impedance plethysmography in the diagnosis of asymptomatic deep vein thrombosis in hip surgery. A venography-controlled study.
Agnelli G; Cosmi B; Ranucci V; Renga C; Mosca S; Lupattelli L; Di Filippo P; Rinonapoli E; Nenci GG
Arch Intern Med; 1991 Nov; 151(11):2167-71. PubMed ID: 1953218
[TBL] [Abstract][Full Text] [Related]
20. Plethysmographic screening for deep venous thrombosis following total hip replacement.
Skjeldal S; Høgevold HE; Reikerås O; Høiseth A
Ann Chir Gynaecol; 1990; 79(1):42-5. PubMed ID: 2357054
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]