These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

78 related articles for article (PubMed ID: 6985553)

  • 1. On the true wear rate of ultra high-molecular-weight polyethylene in the total hip prosthesis.
    Rose RM; Nusbaum HJ; Schneider H; Ries M; Paul I; Crugnola A; Simon SR; Radin EL
    J Bone Joint Surg Am; 1980; 62(4):537-49. PubMed ID: 6985553
    [No Abstract]   [Full Text] [Related]  

  • 2. The seven-year wear of highly cross-linked polyethylene in total hip arthroplasty: a double-blind, randomized controlled trial using radiostereometric analysis.
    Thomas GE; Simpson DJ; Mehmood S; Taylor A; McLardy-Smith P; Gill HS; Murray DW; Glyn-Jones S
    J Bone Joint Surg Am; 2011 Apr; 93(8):716-22. PubMed ID: 21508278
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Morphological characteristics of total joint arthroplasty-derived ultra-high molecular weight polyethylene (UHMWPE) wear debris that provoke inflammation in a murine model of inflammation.
    Sieving A; Wu B; Mayton L; Nasser S; Wooley PH
    J Biomed Mater Res A; 2003 Mar; 64(3):457-64. PubMed ID: 12579559
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A new pin-on-disk wear testing method for simulating wear of polyethylene on cobalt-chrome alloy in total hip arthroplasty.
    Bragdon CR; O'Connor DO; Lowenstein JD; Jasty M; Biggs SA; Harris WH
    J Arthroplasty; 2001 Aug; 16(5):658-65. PubMed ID: 11503127
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [MORF method for assessment of the size and shape of UHMWPE wear microparticles and nanoparticles in periprosthetic tissues].
    Fulín P; Pokorný D; Slouf M; Lapčíková M; Pavlova E; Zolotarevová E
    Acta Chir Orthop Traumatol Cech; 2011; 78(2):131-7. PubMed ID: 21575556
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Wear of conventional and cross-linked ultra-high-molecular-weight polyethylene acetabular cups against polished and roughened CoCr femoral heads in a biaxial hip simulator.
    Saikko V; Calonius O; Keränen J
    J Biomed Mater Res; 2002; 63(6):848-53. PubMed ID: 12418033
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A novel method of cross-linking ultra-high-molecular-weight polyethylene to improve wear, reduce oxidation, and retain mechanical properties. Recipient of the 1999 HAP Paul Award.
    Muratoglu OK; Bragdon CR; O'Connor DO; Jasty M; Harris WH
    J Arthroplasty; 2001 Feb; 16(2):149-60. PubMed ID: 11222887
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A comparison of the wear and physical properties of silane cross-linked polyethylene and ultra-high molecular weight polyethylene.
    Sakoda H; Voice AM; McEwen HM; Isaac GH; Hardaker C; Wroblewski BM; Fisher J
    J Arthroplasty; 2001 Dec; 16(8):1018-23. PubMed ID: 11740757
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Development of an extremely wear-resistant ultra high molecular weight polyethylene for total hip replacements.
    McKellop H; Shen FW; Lu B; Campbell P; Salovey R
    J Orthop Res; 1999 Mar; 17(2):157-67. PubMed ID: 10221831
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Characteristics of metal and ceramic total hip bearing surfaces and their effect on long-term ultra high molecular weight polyethylene wear.
    Davidson JA
    Clin Orthop Relat Res; 1993 Sep; (294):361-78. PubMed ID: 8358943
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Comparison of the in vivo wear rates of 43 surgically retrieved direct compression molded and ram extruded ultra high molecular weight polyethylene acetabular components.
    Rentfrow ED; James SP; Beauregard GP; Lee KR; McLaughlin JR
    Biomed Sci Instrum; 1996; 32():135-41. PubMed ID: 8672661
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Effect of molecular weight, calcium stearate, and sterilization methods on the wear of ultra high molecular weight polyethylene acetabular cups in a hip joint simulator.
    McKellop HA; Shen FW; Campbell P; Ota T
    J Orthop Res; 1999 May; 17(3):329-39. PubMed ID: 10376720
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Role of cyclic plastic deformation in the wear of UHMWPE acetabular cups.
    Wang A; Stark C; Dumbleton JH
    J Biomed Mater Res; 1995 May; 29(5):619-26. PubMed ID: 7622547
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The origin of submicron polyethylene wear debris in total hip arthroplasty.
    McKellop HA; Campbell P; Park SH; Schmalzried TP; Grigoris P; Amstutz HC; Sarmiento A
    Clin Orthop Relat Res; 1995 Feb; (311):3-20. PubMed ID: 7634588
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Evaluation of cytotoxicity of UHMWPE wear debris.
    Rao S; Shirata K; Furukawa KS; Ushida T; Tateishi T; Kanazawa M; Katsube S; Janna S
    Biomed Mater Eng; 1999; 9(4):209-17. PubMed ID: 10674175
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Comparative wear and wear debris under three different counterface conditions of crosslinked and non-crosslinked ultra high molecular weight polyethylene.
    Endo MM; Barbour PS; Barton DC; Fisher J; Tipper JL; Ingham E; Stone MH
    Biomed Mater Eng; 2001; 11(1):23-35. PubMed ID: 11281576
    [TBL] [Abstract][Full Text] [Related]  

  • 17. On morphology of consolidated UHMWPE resin in hip cups.
    Olley RH; Hosier IL; Bassett DC; Smith NG
    Biomaterials; 1999 Nov; 20(21):2037-46. PubMed ID: 10535815
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Isolation of predominantly submicron-sized UHMWPE wear particles from periprosthetic tissues.
    Campbell P; Ma S; Yeom B; McKellop H; Schmalzried TP; Amstutz HC
    J Biomed Mater Res; 1995 Jan; 29(1):127-31. PubMed ID: 7713952
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The measurement and effects of friction and wear in artificial hip joints.
    Walker PS; Salvati E
    J Biomed Mater Res; 1973; 7(3):327-42. PubMed ID: 4717959
    [No Abstract]   [Full Text] [Related]  

  • 20. The influence of molecular weight, crosslinking and counterface roughness on TNF-alpha production by macrophages in response to ultra high molecular weight polyethylene particles.
    Ingram JH; Stone M; Fisher J; Ingham E
    Biomaterials; 2004 Aug; 25(17):3511-22. PubMed ID: 15020125
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 4.