These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

91 related articles for article (PubMed ID: 699346)

  • 1. Interference in estimation of serum copper concentration resulting from use of silicone-coated tubes for collection of blood.
    Healy PJ; Turvey WS; Willats HG
    Clin Chim Acta; 1978 Sep; 88(3):573-6. PubMed ID: 699346
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Trace metal determinations in blood obtained in evacuated collection tubes.
    Williams DM
    Clin Chim Acta; 1979 Nov; 99(1):23-9. PubMed ID: 498541
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Interference in estimation of copper concentration in serum harvested from blood collected into evacuated tubes.
    Healy PJ; Turvey WS
    Aust Vet J; 1978 May; 54(5):261-2. PubMed ID: 687290
    [No Abstract]   [Full Text] [Related]  

  • 4. Interference in the Allégro immunoassay system when blood is collected in silicone-coated tubes.
    Wickus GG; Mordan RJ; Mathews EA
    Clin Chem; 1992 Nov; 38(11):2347-8. PubMed ID: 1424143
    [No Abstract]   [Full Text] [Related]  

  • 5. Effects of storing blood in citrated silicone-coated glass tubes vs. citrated plastic tubes on thromboelastograph variables.
    McDonnell E; Lyons G; Chau S
    Eur J Anaesthesiol; 2007 Mar; 24(3):291-2. PubMed ID: 17087845
    [No Abstract]   [Full Text] [Related]  

  • 6. Measurement of organochlorine levels in postprandial serum or in blood collected in serum separator tubes.
    Longnecker MP; Bernstein L; Bird CL; Yancey AK; Peterson JC
    Cancer Epidemiol Biomarkers Prev; 1996 Sep; 5(9):753-5. PubMed ID: 8877068
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Copper, zinc and aluminum contamination of blood specimens used for determination of these metals].
    Clavel JP; Lavirotte P; Galli A
    Pathol Biol (Paris); 1983 Dec; 31(10):851-4. PubMed ID: 6669401
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Effect of silicone-separator tubes and storage time on ionized calcium in serum.
    Larsson L; Ohman S
    Clin Chem; 1985 Jan; 31(1):169-70. PubMed ID: 3965211
    [No Abstract]   [Full Text] [Related]  

  • 9. Evaluation of evacuated blood-collection tubes: effects of three types of polymeric separators on therapeutic drug-monitoring specimens.
    Landt M; Smith CH; Hortin GL
    Clin Chem; 1993 Aug; 39(8):1712-7. PubMed ID: 8353961
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Zinc in plasma and serum: influence of contamination due to the collection tubes.
    Keyzer JJ; Oosting E; Wolthers BG; Muskiet FA; Hindriks FR; Van der Slik W
    Pharm Weekbl Sci; 1983 Oct; 5(5):248-51. PubMed ID: 6646993
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Altered serum element concentrations due to laboratory usage of Vacutainer tubes.
    Minnick PD; Braselton WE; Meerdink GL; Slanker MR
    Vet Hum Toxicol; 1982 Dec; 24(6):413-4. PubMed ID: 7179713
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Trace metal contamination of evacuated blood collection tubes.
    Nackowski SB; Putnam RD; Robbins DA; Varner MO; White LD; Nelson KW
    Am Ind Hyg Assoc J; 1977 Oct; 38(10):503-8. PubMed ID: 920600
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Unsuitability of evacuated tubes for monitoring heparin therapy by activated partial thromboplastin time.
    Heyns AD; van den Berg DJ; Kleynhans PH; du Toit PW
    J Clin Pathol; 1981 Jan; 34(1):63-8. PubMed ID: 7462439
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Do evacuated blood collection tubes interfere with therapeutic drug monitoring?
    Janknegt R; Lohman JJ; Hooymans PM; Merkus FW
    Pharm Weekbl Sci; 1983 Dec; 5(6):287-90. PubMed ID: 6664820
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Magnesium contamination from Terumo blood collection tubes.
    Dimeski G; Carter A
    Clin Chem; 2006 Aug; 52(8):1612-4. PubMed ID: 16873304
    [No Abstract]   [Full Text] [Related]  

  • 16. [Qualification process for evacuated blood collection tubes: application to the choice of serum collection tubes].
    Guerber F
    Ann Biol Clin (Paris); 2000; 58(6):754-6. PubMed ID: 11098178
    [No Abstract]   [Full Text] [Related]  

  • 17. Prothrombin time ratio is reduced by magnesium contamination in evacuated blood collection tubes.
    van den Besselaar AM; van Dam W; Sturk A; Bertina RM
    Thromb Haemost; 2001 Apr; 85(4):647-50. PubMed ID: 11341499
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Siliconized vs nonsiliconized evaluated blood-collection tubes for free thyroxin measurements.
    McKiel RR; Barron N; Needham CJ; Wilkins TA
    Clin Chem; 1982 Nov; 28(11):2333-4. PubMed ID: 7127794
    [No Abstract]   [Full Text] [Related]  

  • 19. Extraction of copper and zinc from rubber and silicone stoppers.
    Bogden JD; Zadzielski E; Aviv A
    J Toxicol Environ Health; 1983; 11(4-6):967-9. PubMed ID: 6620423
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Sterile Corvac silicone gel tubes: efficacy and storage capabilities.
    Frankel S
    Am J Clin Pathol; 1984 Feb; 81(2):240-2. PubMed ID: 6421148
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.