These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

104 related articles for article (PubMed ID: 7003015)

  • 1. Light scattering and absorption--developments in immunology.
    Deverill I; Reeves WG
    J Immunol Methods; 1980; 38(3-4):191-204. PubMed ID: 7003015
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Immunonephelometric and immunoturbidimetric assays for proteins.
    Whicher JT; Price CP; Spencer K
    Crit Rev Clin Lab Sci; 1983; 18(3):213-60. PubMed ID: 6339164
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Comparison of turbidimetric and light-scattering measurements of immunoglobulins by use of a centrifugal analyzer with absorbance and fluorescence/light-scattering optics.
    Hills LP; Tiffany TO
    Clin Chem; 1980 Sep; 26(10):1459-66. PubMed ID: 7408174
    [TBL] [Abstract][Full Text] [Related]  

  • 4. The determination of serum immunoglobulins by automated nephelometric analysis.
    Fritsche HA; De Leon E
    Am J Med Technol; 1975 Apr; 41(4):136-44. PubMed ID: 805537
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Immunonephelometric assays.
    Ackerman E; Rosevear JW
    Med Prog Technol; 1979 Jan; 6(2):81-90. PubMed ID: 372782
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Some problems in the correction for intrinsic light-scattering of samples in specific protein analysis by automated immunoprecipitation.
    Shenkin A; Morrison B; Robertson DA
    Ann Clin Biochem; 1977 May; 14(3):163-70. PubMed ID: 326134
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Airborne dust particle counting techniques.
    Sharma SG; Prasad BD
    Environ Monit Assess; 2006 Mar; 114(1-3):191-8. PubMed ID: 16565805
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Immunonephelometry of apolipoprotein B with a centrifugal analyzer.
    Hanson NQ; LeGeault TS; Freier EF
    Clin Chem; 1987 Oct; 33(10):1882-4. PubMed ID: 3311468
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Evaluation of kinetic light scattering as an approach to the measurement of specific proteins with the centrifugal analyzer. II. Theoretical considerations.
    Buffone GJ; Savory J; Hermans J
    Clin Chem; 1975 Nov; 21(12):1735-46. PubMed ID: 1182993
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Evaluation of the light scattering and the turbidity microtiter plate-based methods for the detection of the excipient-mediated drug precipitation inhibition.
    PetruĆĄevska M; Urleb U; Peternel L
    Eur J Pharm Biopharm; 2013 Nov; 85(3 Pt B):1148-56. PubMed ID: 24056092
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Automated fibronectin assay using light-scattering optics on a centrifugal analyzer.
    Steele BW; Hills LP; Hellman RL; Civantos F; Kent J
    Clin Biochem; 1984 Jun; 17(3):157-61. PubMed ID: 6733895
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Light scattering and its application for the clinical laboratory.
    Deaton C
    Am J Med Technol; 1982 Aug; 48(8):657-61. PubMed ID: 7137207
    [TBL] [Abstract][Full Text] [Related]  

  • 13. The effect of laser deterioration on nephelometer performance.
    Salkie ML
    Clin Chim Acta; 1985 Nov; 152(3):363-6. PubMed ID: 4064339
    [No Abstract]   [Full Text] [Related]  

  • 14. An evaluation of the Hyland laser nephelometer PDQ system for the measurement of immunoglobulins.
    Whicher JT; Perry DE; Hobbs JR
    Ann Clin Biochem; 1978 Mar; 15(2):77-85. PubMed ID: 637513
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Letter: Turbidimetry vs. light scattering in immunochemistry.
    Buffone GJ
    Clin Chem; 1976 Apr; 22(4):556. PubMed ID: 1253440
    [No Abstract]   [Full Text] [Related]  

  • 16. Rapid immunochemical determination of plasma fibronectin with a centrifugal analyzer.
    Hamel G; Toazara DJ; Mark J
    Ann Biol Clin (Paris); 1982; 40(6):661-5. PubMed ID: 6819790
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Comparative evaluation of an automated kinetic laser nephelometer with other immunoprecipitin technics for the assay of serum immunoglobulins.
    Dito WR; Tucker ES; Nakamura RM
    Am J Clin Pathol; 1981 Dec; 76(6):753-9. PubMed ID: 7315793
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Fully automated time domain spectrometer for the absorption and scattering characterization of diffusive media.
    Pifferi A; Torricelli A; Taroni P; Comelli D; Bassi A; Cubeddu R
    Rev Sci Instrum; 2007 May; 78(5):053103. PubMed ID: 17552808
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Measurement of the absorption and scattering properties of turbid liquid foods using hyperspectral imaging.
    Qin J; Lu R
    Appl Spectrosc; 2007 Apr; 61(4):388-96. PubMed ID: 17456257
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Light scattering studies of the solubilization of some esters of p-aminobenzoic acid by lysophosphatidylcholine.
    Hunt MJ; Saunders L
    J Pharm Pharmacol; 1980 Sep; 32(9):615-8. PubMed ID: 6107361
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.