These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

121 related articles for article (PubMed ID: 7011017)

  • 1. The value of protective isolation in preventing nosocomial infections in high risk patients.
    Pizzo PA
    Am J Med; 1981 Mar; 70(3):631-7. PubMed ID: 7011017
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Impact of air filtration on nosocomial Aspergillus infections. Unique risk of bone marrow transplant recipients.
    Sherertz RJ; Belani A; Kramer BS; Elfenbein GJ; Weiner RS; Sullivan ML; Thomas RG; Samsa GP
    Am J Med; 1987 Oct; 83(4):709-18. PubMed ID: 3314494
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The influence of high-efficiency particulate air filtration on mortality and fungal infection among highly immunosuppressed patients: a systematic review.
    Eckmanns T; Rüden H; Gastmeier P
    J Infect Dis; 2006 May; 193(10):1408-18. PubMed ID: 16619189
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Protective isolation: who needs it?
    Fenelon LE
    J Hosp Infect; 1995 Jun; 30 Suppl():218-22. PubMed ID: 7560953
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Simple and microbiologically safe portable transport unit for patients requiring protected isolation.
    Talbot TL; Pizzo PA
    J Clin Microbiol; 1980 Mar; 11(3):234-7. PubMed ID: 6769945
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Infection prevention during profound granulocytopenia. New approaches to alimentary canal microbial suppression.
    Schimpff SC
    Ann Intern Med; 1980 Aug; 93(2):358-61. PubMed ID: 7406385
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Infection prevention in acute nonlymphocytic leukemia. Laminar air flow room reverse isolation with oral, nonabsorbable antibiotic prophylaxis.
    Schimpff SC; Greene WH; Young VM; Fortner CL; Cusack N; Block JB; Wiernik PH
    Ann Intern Med; 1975 Mar; 82(3):351-8. PubMed ID: 1054222
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Positive-pressure isolation and the prevention of invasive aspergillosis. What is the evidence?
    Humphreys H
    J Hosp Infect; 2004 Feb; 56(2):93-100; quiz 163. PubMed ID: 15019219
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Efficacy of high-efficiency particulate air filtration in preventing aspergillosis in immunocompromised patients with hematologic malignancies.
    Hahn T; Cummings KM; Michalek AM; Lipman BJ; Segal BH; McCarthy PL
    Infect Control Hosp Epidemiol; 2002 Sep; 23(9):525-31. PubMed ID: 12269451
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Efficacy of prevention by high-efficiency particulate air filtration or laminar airflow against Aspergillus airborne contamination during hospital renovation.
    Cornet M; Levy V; Fleury L; Lortholary J; Barquins S; Coureul MH; Deliere E; Zittoun R; Brücker G; Bouvet A
    Infect Control Hosp Epidemiol; 1999 Jul; 20(7):508-13. PubMed ID: 10432165
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Prevention of infection on the oncology unit.
    Crane LR; Emmer DR; Grguras A
    Nurs Clin North Am; 1980 Dec; 15(4):843-55. PubMed ID: 7005878
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Infection prevention in patients with cancer: microbiological evaluation of portable laminar air flow isolation, topical chlorhexidine, and oral non-absorbable antibiotics.
    Spiers AS; Dias SF; Lopez JA
    J Hyg (Lond); 1980 Jun; 84(3):457-65. PubMed ID: 7052225
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Evaluation of microbial contamination of air in two haematology departments equipped with ventilation systems with different filtration devices.
    Crimi P; Valgiusti M; Macrina G; Grieco A; Massone L; Ciucci A; Ansaldi F; Sticchi L; Sasso L; Del Buono S; Durando P
    J Prev Med Hyg; 2009 Mar; 50(1):33-6. PubMed ID: 19771758
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Protective isolation in a burns unit: the use of plastic isolators and air curtains.
    Lowbury EJ; Babb JR; Ford PM
    J Hyg (Lond); 1971 Dec; 69(4):529-46. PubMed ID: 5002642
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Microbial ecology of protective isolation room: Air and Surfaces.
    Sbibih Y; Saddari A; Alla I; Abdesselami O; Ben Moussa C; Ezrari S; Benaissa E; Ben Lahlou Y; Elouennass M; Maleb A
    Tunis Med; 2024 Jul; 102(7):394-398. PubMed ID: 38982962
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Unidirectional ("laminar") flow ventilation system for patient isolation.
    Lidwell OM; Towers AG
    Lancet; 1972 Feb; 1(7746):347-50. PubMed ID: 4109737
    [No Abstract]   [Full Text] [Related]  

  • 17. [Role of disinfection in reducing microbial contamination in isolators for immunocompromised patients].
    Tolkacheva TV; Ermakova GL; Mel'nikova GN; Abakumov EM; Golosova TV
    Gig Sanit; 1986 Nov; (11):26-8. PubMed ID: 3803937
    [No Abstract]   [Full Text] [Related]  

  • 18. Clinical use of reverse isolation in a protected environment.
    Bláha M; Vanásek J; Mĕrka V; Splino M; Malý J; Siroký O
    Folia Microbiol (Praha); 1979; 24(1):88-95. PubMed ID: 437588
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Prevention of infection in patients with agranulocytosis through isolation and whole-body decontamination].
    Fopp M; Gasser A; Eigenmann B; Jungi WF; Meuret G; Senn HJ
    Schweiz Med Wochenschr; 1975 Aug; 105(35):1123-5. PubMed ID: 808849
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Reverse isolation in bone marrow transplantation: ultra-clean room compared with laminar flow technique. I. Isolation systems.
    Vossen JM; van der Waay D
    Rev Eur Etud Clin Biol; 1972 May; 17(5):457-61. PubMed ID: 4567425
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 7.