These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

100 related articles for article (PubMed ID: 70328)

  • 1. [Pre-stained slides for differential blood counts (author's transl)].
    Bostjancic W; Braun JS; Reheis G; Weisshaar D; Akkerman JW; Banauch D; Koller PU
    Dtsch Med Wochenschr; 1977 Aug; 102(33):1175-7, 1185. PubMed ID: 70328
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [Application of an automatic blood cell analyzer "MICROX" to the blood of experimental animals. I. Differential counts of white blood cells in monkeys and dogs].
    Hagino K; Ochiai T; Matsumoto K; Sekita K; Kawasaki Y; Furuya T
    Jikken Dobutsu; 1982 Oct; 31(4):259-64. PubMed ID: 7169083
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [CSF cytology using prestained slides (author's transl)].
    Kleine TO; Flury R; Tritschler W
    Dtsch Med Wochenschr; 1977 Aug; 102(34):1216-21. PubMed ID: 71980
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Differential blood counts with EDTA blood (author's transl)].
    Hauswaldt C; Schröder U
    Dtsch Med Wochenschr; 1973 Dec; 98(50):2391-2 passim. PubMed ID: 4202986
    [No Abstract]   [Full Text] [Related]  

  • 5. [Practical experiences with the Hematrak (author's transl)].
    Witte S
    Nouv Rev Fr Hematol (1978); 1978 Jun; 20(2):293-6. PubMed ID: 704344
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Preparation techniques of blood and bone marrow for automated white cell analysis.
    Smit JW; Huiges W; Halie MR
    Microsc Acta Suppl; 1980; Suppl 4():96-101. PubMed ID: 6157079
    [No Abstract]   [Full Text] [Related]  

  • 7. Automated differential leukocyte counts.
    Morse EE; Nashed A; Spilove L
    Ann Clin Lab Sci; 1989; 19(3):155-60. PubMed ID: 2658725
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Presence of abnormal cells.
    Mayer K
    Blood Cells; 1985; 11(1):25-30. PubMed ID: 4074891
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Studies on the efficient application by STKS and 8200].
    Mishima S; Unshima T; Yoshida Y; Endo J
    Rinsho Byori; 1992 Jun; 40(6):577-85. PubMed ID: 1513029
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [Satellite platelets: a warning sign in the automation of leucocyte differential count (author's transl)].
    Woessner S; Masanas J; Bustamante E
    Sangre (Barc); 1979; 24(3):345-8. PubMed ID: 112698
    [No Abstract]   [Full Text] [Related]  

  • 11. [A problems in diagnosis of "leucocyturia". A simple method for a quantitative evaluation of urinary cell concentration (author's transl)].
    Brühl P; Mikolai D; Vahlensieck W
    Urologe A; 1979 Sep; 18(5):278-83. PubMed ID: 494453
    [TBL] [Abstract][Full Text] [Related]  

  • 12. White blood cell counts by automated and manual methods with backlighting.
    Trinh M
    Clin Lab Sci; 1991; 4(1):45-7. PubMed ID: 10149412
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A clinical trial of three-part electronic differential white blood cell counts.
    Charache S; Nelson L; Keyser E; Metzger P
    Arch Intern Med; 1985 Oct; 145(10):1852-5. PubMed ID: 3899037
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Rapid single-step method for flow cytometric detection of surface and intracellular antigens using whole blood.
    Francis C; Connelly MC
    Cytometry; 1996 Sep; 25(1):58-70. PubMed ID: 8875055
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Recognition of white blood cells with an interactive morphometry system(T.A.S.).
    Bins M; Gelsema E; van Montfort LH; Halie MR
    Microsc Acta Suppl; 1980; Suppl 4():102-7. PubMed ID: 6157076
    [No Abstract]   [Full Text] [Related]  

  • 16. Enumeration of lymphocyte populations in whole peripheral blood with alkaline phosphatase-labelled reagents. A method for routine clinical use.
    Druguet M; Pepys MB
    Clin Exp Immunol; 1977 Jul; 29(1):162-7. PubMed ID: 891032
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Morphologic analysis of blood cells].
    Kikuchi T; Takeda Y; Shimizu A
    Rinsho Byori; 1995 Sep; 43(9):917-24. PubMed ID: 7474455
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A multiwell cell settling and adherence chamber for morphology and differential counting.
    Leonard EJ; Yoshimura T; Skeel A; Goodwin R
    Biotechniques; 1990 Dec; 9(6):684, 686, 688-9. PubMed ID: 1702974
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Application of an automatic blood cell counter, MICROX, to experimental animals. II. Leukocyte differential count in rabbits, rats, and mice].
    Matsumoto K; Ochiai T; Sekita K; Kawasaki Y; Yasuhara K; Furuya T
    Jikken Dobutsu; 1983 Jul; 32(3):115-22. PubMed ID: 6653678
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Differential blood counts from cell concentrates. A comparison with routine differential blood counts.
    Pflieger H; Gaus W; Dietrich M
    Acta Haematol; 1979; 61(3):150-4. PubMed ID: 108891
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.