These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
134 related articles for article (PubMed ID: 7032846)
1. A practical procedure for measuring functional residual capacity during mechanical ventilation with or without PEEP. Weaver LJ; Pierson DJ; Kellie R; Bonner B; Craig KC Crit Care Med; 1981 Dec; 9(12):873-7. PubMed ID: 7032846 [TBL] [Abstract][Full Text] [Related]
2. Measurement of functional residual capacity and pulmonary carbon monoxide diffusing capacity during mechanical ventilation with PEEP. Kondo T; Kurata T; Takasaki Y; Ohta Y; Yamabayashi H Tokai J Exp Clin Med; 1982 Sep; 7(5):561-73. PubMed ID: 6763783 [TBL] [Abstract][Full Text] [Related]
3. Measurement of functional residual capacity of the lung by partial CO2 rebreathing method during acute lung injury in animals. Brewer LM; Haryadi DG; Orr JA Respir Care; 2007 Nov; 52(11):1480-9. PubMed ID: 17971251 [TBL] [Abstract][Full Text] [Related]
4. Evaluation of a CO2 partial rebreathing functional residual capacity measurement method for use during mechanical ventilation. Brewer L; Orr J; Fulcher E; Markewitz B J Clin Monit Comput; 2011 Dec; 25(6):397-404. PubMed ID: 22057246 [TBL] [Abstract][Full Text] [Related]
5. End-Expiratory Lung Volume in Patients with Acute Respiratory Distress Syndrome: A Time Course Analysis. Kalenka A; Gruner F; Weiß C; Viergutz T Lung; 2016 Aug; 194(4):527-34. PubMed ID: 27169535 [TBL] [Abstract][Full Text] [Related]
6. A simple method for measuring the effect of PEEP on functional residual capacity during mechanical ventilation. Ibañez J; Raurich JM; Moris SG Crit Care Med; 1982 May; 10(5):332-4. PubMed ID: 7042202 [TBL] [Abstract][Full Text] [Related]
7. Measurement of functional residual capacity during mechanical ventilation. Comparison of a computerized open nitrogen washout method with a closed helium dilution method. Ibañez J; Raurich JM; Moris SG Intensive Care Med; 1983; 9(2):91-3. PubMed ID: 6343447 [TBL] [Abstract][Full Text] [Related]
8. Temporal responses of functional residual capacity and oxygen tension to changes in positive end-expiratory pressure. Rose DM; Downs JB; Heenan TJ Crit Care Med; 1981 Feb; 9(2):79-82. PubMed ID: 7006917 [TBL] [Abstract][Full Text] [Related]
9. Measurement of functional residual capacity by helium dilution during partial support ventilation: in vitro accuracy and in vivo precision of the method. Di Marco F; Rota Sperti L; Milan B; Stucchi R; Centanni S; Brochard L; Fumagalli R Intensive Care Med; 2007 Dec; 33(12):2109-15. PubMed ID: 17703280 [TBL] [Abstract][Full Text] [Related]
10. A simplified method to determine functional residual capacity during mechanical ventilation. Heldt GP; Peters RM Chest; 1978 Nov; 74(5):492-6. PubMed ID: 738086 [TBL] [Abstract][Full Text] [Related]
11. [A simple method for determination of the functional residual capacity during artificial ventilation (author's transl)]. Stokke T; Hensel I; Burchardi H Anaesthesist; 1981 Mar; 30(3):124-30. PubMed ID: 7224140 [TBL] [Abstract][Full Text] [Related]
12. Establishing functional residual capacity at birth: the effect of sustained inflation and positive end-expiratory pressure in a preterm rabbit model. te Pas AB; Siew M; Wallace MJ; Kitchen MJ; Fouras A; Lewis RA; Yagi N; Uesugi K; Donath S; Davis PG; Morley CJ; Hooper SB Pediatr Res; 2009 May; 65(5):537-41. PubMed ID: 19190537 [TBL] [Abstract][Full Text] [Related]
13. Computer-controlled optimization of positive end-expiratory pressure. East TD; Andriano KP; Pace NL Crit Care Med; 1986 Sep; 14(9):792-7. PubMed ID: 3091319 [TBL] [Abstract][Full Text] [Related]
14. Measurements of functional residual capacity during intensive care treatment: the technical aspects and its possible clinical applications. Heinze H; Eichler W Acta Anaesthesiol Scand; 2009 Oct; 53(9):1121-30. PubMed ID: 19681779 [TBL] [Abstract][Full Text] [Related]
15. Evaluation of respiratory inductive plethysmography in controlled ventilation: measurement of tidal volume and PEEP-induced changes of end-expiratory lung volume. Neumann P; Zinserling J; Haase C; Sydow M; Burchardi H Chest; 1998 Feb; 113(2):443-51. PubMed ID: 9498965 [TBL] [Abstract][Full Text] [Related]
16. Functional residual capacity and ventilation homogeneity in mechanically ventilated small neonates. Vilstrup CT; Björklund LJ; Larsson A; Lachmann B; Werner O J Appl Physiol (1985); 1992 Jul; 73(1):276-83. PubMed ID: 1506381 [TBL] [Abstract][Full Text] [Related]
17. Functional residual capacity and respiratory mechanics as indicators of aeration and collapse in experimental lung injury. Rylander C; Högman M; Perchiazzi G; Magnusson A; Hedenstierna G Anesth Analg; 2004 Mar; 98(3):782-9, table of contents. PubMed ID: 14980937 [TBL] [Abstract][Full Text] [Related]
18. The impact of positive end-expiratory pressure on functional residual capacity and ventilation homogeneity impairment in anesthetized children exposed to high levels of inspired oxygen. von Ungern-Sternberg BS; Regli A; Schibler A; Hammer J; Frei FJ; Erb TO Anesth Analg; 2007 Jun; 104(6):1364-8, table of contents. PubMed ID: 17513627 [TBL] [Abstract][Full Text] [Related]
19. The functional residual capacity of infants with respiratory distress syndrome. Richardson P; Bose CL; Carlstrom JR Acta Paediatr Scand; 1986 Mar; 75(2):267-71. PubMed ID: 3515844 [TBL] [Abstract][Full Text] [Related]
20. Determination of auto-PEEP during spontaneous and controlled ventilation by monitoring changes in end-expiratory thoracic gas volume. Hoffman RA; Ershowsky P; Krieger BP Chest; 1989 Sep; 96(3):613-6. PubMed ID: 2670467 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]