These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

215 related articles for article (PubMed ID: 7035418)

  • 1. Thermodilution technique for measurement of cardiac output during artificial ventilation.
    Jansen JR; Schreuder JJ; Bogaard JM; van Rooyen W; Versprille A
    J Appl Physiol Respir Environ Exerc Physiol; 1981 Sep; 51(3):584-91. PubMed ID: 7035418
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Improvement of cardiac output estimation by the thermodilution method during mechanical ventilation.
    Jansen JR; Versprille A
    Intensive Care Med; 1986; 12(2):71-9. PubMed ID: 3700840
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Continuous measurement of cardiac output by the Fick principle: clinical validation in intensive care.
    Keinänen O; Takala J; Kari A
    Crit Care Med; 1992 Mar; 20(3):360-5. PubMed ID: 1541096
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Effect of the mechanical ventilatory cycle on thermodilution right ventricular volumes and cardiac output.
    Groeneveld AB; Berendsen RR; Schneider AJ; Pneumatikos IA; Stokkel LA; Thijs LG
    J Appl Physiol (1985); 2000 Jul; 89(1):89-96. PubMed ID: 10904039
    [TBL] [Abstract][Full Text] [Related]  

  • 5. The effects of the respiratory cycle by mechanical ventilation on cardiac output measured using the thermodilution method.
    Tajiri J; Katsuya H; Okamoto K; Urata K; Sato T
    Jpn Circ J; 1984 Apr; 48(4):328-30. PubMed ID: 6716631
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Near continuous cardiac output by thermodilution.
    Jansen JR; Johnson RW; Yan JY; Verdouw PD
    J Clin Monit; 1997 Jul; 13(4):233-9. PubMed ID: 9269617
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Effect of ventilatory settings on accuracy of cardiac output measurement using partial CO(2) rebreathing.
    Tachibana K; Imanaka H; Miyano H; Takeuchi M; Kumon K; Nishimura M
    Anesthesiology; 2002 Jan; 96(1):96-102. PubMed ID: 11753008
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Impact of Positive End-Expiratory Pressure on Thermodilution-Derived Right Ventricular Parameters in Mechanically Ventilated Critically Ill Patients.
    Cherpanath TG; Lagrand WK; Binnekade JM; Schneider AJ; Schultz MJ; Groeneveld JA
    J Cardiothorac Vasc Anesth; 2016 Jun; 30(3):632-8. PubMed ID: 26703971
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Effects of mechanical ventilation on the measurement of cardiac output by thermodilution.
    Synder JV; Powner DJ
    Crit Care Med; 1982 Oct; 10(10):677-82. PubMed ID: 7116891
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Thermodilution cardiac output measurements during conventional and high-frequency ventilation.
    Sherry KM; Feneck RO; Normandale J
    J Cardiothorac Anesth; 1988 Jun; 2(3):320-5. PubMed ID: 17171867
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The Precision of Pulmonary Artery Catheter Bolus Thermodilution Cardiac Output Measurements Varies With the Clinical Situation.
    Kirkeby-Garstad I; Trønnes H; Stenseth R; Sellevold OF; Aadahl P; Skogvoll E
    J Cardiothorac Vasc Anesth; 2015 Aug; 29(4):881-8. PubMed ID: 25976600
    [TBL] [Abstract][Full Text] [Related]  

  • 12. An adequate strategy for the thermodilution technique in patients during mechanical ventilation.
    Jansen JR; Schreuder JJ; Settels JJ; Kloek JJ; Versprille A
    Intensive Care Med; 1990; 16(7):422-5. PubMed ID: 2269709
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Right ventricular function assessed by thermodilution technique during apnea and mechanical ventilation.
    Assmann R; Heidelmeyer CF; Trampisch HJ; Mottaghy K; Versprille A; Sandmann W; Falke KJ
    Crit Care Med; 1991 Jun; 19(6):810-7. PubMed ID: 2055059
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Improved accuracy and precision of thermodilution cardiac output measurement using a dual thermistor catheter system.
    Lehmann KG; Platt MS
    J Am Coll Cardiol; 1999 Mar; 33(3):883-91. PubMed ID: 10080494
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Effects of intermittent positive-pressure ventilation on cardiac output measurements by thermodilution.
    Okamoto K; Komatsu T; Kumar V; Sanchala V; Kubal K; Bhalodia R; Shibutani K
    Crit Care Med; 1986 Nov; 14(11):977-80. PubMed ID: 3533423
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Effects of the respiratory cycle on cardiac output measurements: reproducibility of data enhanced by timing the thermodilution injections in dogs.
    Armengol J; Man GC; Balsys AJ; Wells AL
    Crit Care Med; 1981 Dec; 9(12):852-4. PubMed ID: 7032845
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Validation of cardiac output measurements with noninvasive Doppler echocardiography by thermodilution and Fick methods in newborn piglets.
    Welch E; Duara S; Suguihara C; Bandstra E; Bancalari E
    Biol Neonate; 1994; 66(2-3):137-45. PubMed ID: 7993947
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Measuring cardiac output in critically Ill patients: disagreement between thermodilution-, calculated-, expired gas-, and oxygen consumption-based methods.
    Sherman MS; Kosinski R; Paz HL; Campbell D
    Cardiology; 1997; 88(1):19-25. PubMed ID: 8960620
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Respiration and measurement of cardiac output by thermodilution and central or peripheral dye dilution.
    Delhaas T; Mook GA; Zijlstra WG
    J Appl Physiol (1985); 1992 Sep; 73(3):1047-51. PubMed ID: 1400016
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Extrapolation of thermodilution curves obtained during a pause in artificial ventilation.
    Jansen JR; Bogaard JM; Versprille A
    J Appl Physiol (1985); 1987 Oct; 63(4):1551-7. PubMed ID: 3693193
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.