These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

105 related articles for article (PubMed ID: 7048368)

  • 1. An experimental study of the sleeve technique in microarterial anastomoses.
    Sully L; Nightingale MG; O'Brien BM; Hurley JV
    Plast Reconstr Surg; 1982 Aug; 70(2):186-92. PubMed ID: 7048368
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Use of longitudinal invaginating matrix sutures in microarterial sleeve anastomoses.
    Güneren E; Odaci E; Yildiz L; Akbaş H; Eroğlu L; Kaplan S
    Scand J Plast Reconstr Surg Hand Surg; 2004; 38(1):1-4. PubMed ID: 15074715
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Microarterial sutureless sleeve anastomosis using a polymeric adhesive: an experimental study.
    Casanova R; Herrera GA; Vàsconez Engels B; Velasquez C; Grotting JC
    J Reconstr Microsurg; 1987 Apr; 3(3):201-7, 209-10. PubMed ID: 3598942
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Classification and comparison of five techniques of end-to-end microarterial anastomoses in rats: a new proposed technique.
    Gahankari DR; Lalwani NR; Phatak AM
    Microsurgery; 1995; 16(12):793-802. PubMed ID: 8844661
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Introduction of loop sutures in microsurgical telescoping anastomosis.
    Saitoh S; Nakatsuchi Y
    Br J Plast Surg; 1993 Mar; 46(2):105-9. PubMed ID: 8461897
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Further technical considerations of the sleeve microanastomosis.
    Kanaujia RR; Hoi KI; Miyamoto Y; Ikuta Y; Tsuge K
    Plast Reconstr Surg; 1988 May; 81(5):725-34. PubMed ID: 3362988
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Microvascular anastomosis using 2-octyl cyanoacrylate in the rat femoral artery.
    Hall WW; Wrye SW; Banducci DR; Ehrlich P
    Ann Plast Surg; 2000 May; 44(5):508-11. PubMed ID: 10805301
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Microvascular surgical experimental thrombosis model: rationale and design.
    Kersh RA; Handren J; Hergrueter C; May JW
    Plast Reconstr Surg; 1989 May; 83(5):866-72; discussion 873-4. PubMed ID: 2710836
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Microarterial anastomoses in the rat: the influence of different suture materials on the patency, strength and the electron microscopic appearance of the vessels.
    Pitt TT; Humphries NL
    Br J Plast Surg; 1982 Apr; 35(2):150-5. PubMed ID: 7082888
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Comparison of tensile strength and thrombus formation between mechanical microvascular anastomoses using a biodegradable ring device and sutured anastomoses.
    Ichikawa M; Muneshige H; Ikuta Y
    J Reconstr Microsurg; 2002 Feb; 18(2):131-6; discussion 137-9. PubMed ID: 11823945
    [TBL] [Abstract][Full Text] [Related]  

  • 11. New end-to-end microvascular anastomosis with geometrically adaptable ends technique: an experimental study on rats.
    Demiralp CO; Serel S; Zeyrek T; Demirseren ME; Ergun H; Yormuk E
    Bratisl Lek Listy; 2011; 112(9):483-7. PubMed ID: 21954523
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Patency rates in end to side anastomoses in the rabbit.
    Brennen MD; O'Brien BM
    Br J Plast Surg; 1979 Jan; 32(1):24-30. PubMed ID: 427305
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Histopathology of microarterial anastomoses: end-to-end versus end-in-end (sleeve) technique.
    Siemionow M
    J Hand Surg Am; 1990 Jul; 15(4):619-25. PubMed ID: 2380526
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Challenging Alexis Carrel: a study in alternate microvascular techniques.
    Aviles AJ; Theodorou S; Sekosen M; Schraufnagel D; Ramasastry S
    Neurol Res; 2004 Dec; 26(8):809-15. PubMed ID: 15727264
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A new anastomosis technique for large-calibered vein grafts.
    Harashina T; Takaki JL
    Microsurgery; 1983; 4(3):171-5. PubMed ID: 6366445
    [TBL] [Abstract][Full Text] [Related]  

  • 16. End-to-side-anastomosis in the dog using the 3M precise microvascular anastomotic system: a comparative study.
    Li YN; Wood MB
    J Reconstr Microsurg; 1991 Oct; 7(4):345-50; discussion 351-2. PubMed ID: 1753377
    [TBL] [Abstract][Full Text] [Related]  

  • 17. The ring technique for end-to-side microvascular anastomosis.
    Weinrib HP; Cook JQ; Penn RD
    Microsurgery; 1984; 5(2):76-9. PubMed ID: 6379369
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A new and easier way to anastomose microvessels. An experimental study in rats.
    Lauritzen C
    Scand J Plast Reconstr Surg; 1978; 12(3):291-4. PubMed ID: 368973
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Microvascular repair after the sleeve anastomosis. An ultrastructural study in the rat femoral vessels.
    Lauritzen C; Hansson HA
    Scand J Plast Reconstr Surg; 1980; 14(1):65-70. PubMed ID: 7384758
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Exploration of the intravascular stenting method for sub 1-mm vessels.
    Bossut C; Barbier O
    J Reconstr Microsurg; 2011 Oct; 27(8):461-8. PubMed ID: 21780016
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.