These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
95 related articles for article (PubMed ID: 7048993)
21. [Dysfunction of vaporizers and nitrous oxide: solubility or viscosity?]. Deriaz H; Duranteau R; Lienhart A Ann Fr Anesth Reanim; 1994; 13(1):27-32. PubMed ID: 8092579 [TBL] [Abstract][Full Text] [Related]
22. [Vaporizer malfunction--a cause of high concentration halothane vapor delivery]. Yamada T; Masuda J; Takeda J; Sekiguchi H; Fukushima K Masui; 1994 Mar; 43(3):421-5. PubMed ID: 8182893 [TBL] [Abstract][Full Text] [Related]
23. Administration of halothane in the 0-0.5 per cent concentration range with the Fluotec Mark 2 and Mark 3 vaporizers. Latto IP Br J Anaesth; 1973 Jun; 45(6):563-9. PubMed ID: 4718247 [No Abstract] [Full Text] [Related]
24. Inadvertent change of volatile anesthetics in anesthesia machines. Karis JH; Menzel DB Anesth Analg; 1982 Jan; 61(1):53-5. PubMed ID: 7198415 [TBL] [Abstract][Full Text] [Related]
25. [Action of halothane vaporizers under the influence of respiratory pressure]. Uter P; Koch H; Stoffregen J Anaesthesist; 1966 May; 15(5):175-6. PubMed ID: 5987187 [No Abstract] [Full Text] [Related]
27. Spontaneous respiration versus controlled ventilation anaesthesia with halothane for intra-ocular surgery. van den Berg AA; Honjol NM; Prabhu NV; Pace NA; Conn DA Eur J Anaesthesiol; 1995 Mar; 12(2):147-53. PubMed ID: 7781634 [TBL] [Abstract][Full Text] [Related]
28. [Effects of back-pressure on the anesthetic concentration from vaporizers]. Inoue M; Aoki T Masui; 1968 Mar; 17(3):237-41. PubMed ID: 5244789 [No Abstract] [Full Text] [Related]
30. Effects of low flow rates on the inspired oxygen concentration in circle absorber circuit. Kam CA; Tham SH Singapore Med J; 1979 Mar; 20(1):274-7. PubMed ID: 377500 [No Abstract] [Full Text] [Related]
31. [Mass flow anesthesia delivery system and its application]. Takahashi M; Ishida A; Toyooka H; Amaha K Iyodenshi To Seitai Kogaku; 1989 Mar; 27(1):19-25. PubMed ID: 2754861 [TBL] [Abstract][Full Text] [Related]
32. THE CONCENTRATION OF HALOTHANE BY THE COMBINED USE OF FLUOTEC VAPORIZER AND ENGSTROEM RESPIRATOR. GORDH T; HALLEN B; OKMIAN L; STERN B Acta Anaesthesiol Scand; 1964; 8():97-105. PubMed ID: 14164094 [No Abstract] [Full Text] [Related]
33. Dependence of the output of a halothane vaporizer on thymol concentration. Gray WM Anaesthesia; 1988 Dec; 43(12):1047-9. PubMed ID: 3232783 [TBL] [Abstract][Full Text] [Related]
34. Influence of pressure- and flow-triggered synchronous intermittent mandatory ventilation on inspiratory muscle work. Sassoon CS; Del Rosario N; Fei R; Rheeman CH; Gruer SE; Mahutte CK Crit Care Med; 1994 Dec; 22(12):1933-41. PubMed ID: 7988129 [TBL] [Abstract][Full Text] [Related]
35. Halothane concentrations obtained with a Drager "vapor" vaporizer. HILL DW Br J Anaesth; 1963 May; 35():285-9. PubMed ID: 13954509 [No Abstract] [Full Text] [Related]
36. Use of the Fluotec Mark II for halothane-air anesthesia. Counts HK; Carden WD; Petty WC Anesth Analg; 1973 Mar; 52(2):181-7. PubMed ID: 4735276 [No Abstract] [Full Text] [Related]
37. Service improves performance of unattended draw-over halothane vaporizers. Hansen D Trop Doct; 2001 Jan; 31(1):29-31. PubMed ID: 11205598 [TBL] [Abstract][Full Text] [Related]
38. Inadvertent administration of halothane with the Fluotec Mk. 3 vaporiser. Bar ZG Anaesth Intensive Care; 1984 Nov; 12(4):378. PubMed ID: 6517303 [No Abstract] [Full Text] [Related]
39. [Improved climatization of anesthetic gases by modifying the Sulla 808 V anesthesia equipment]. Kleemann PP Anaesthesiol Reanim; 1995; 20(3):71-5. PubMed ID: 8526962 [TBL] [Abstract][Full Text] [Related]