These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

133 related articles for article (PubMed ID: 7055896)

  • 21. Activity and interference effects in measurement of ionized calcium with ion-selective electrodes.
    Grima JM; Brand MJ
    Clin Chem; 1977 Nov; 23(11):2048-54. PubMed ID: 21042
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Characterization of a new ion selective electrode for ionized magnesium in whole blood, plasma, serum, and aqueous samples.
    Altura BT; Shirey TL; Young CC; Dell'Orfano K; Hiti J; Welsh R; Yeh Q; Barbour RL; Altura BM
    Scand J Clin Lab Invest Suppl; 1994; 217():21-36. PubMed ID: 7939382
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Thiocyanate in smokers interferes with the Nova magnesium ion-selective electrode.
    Rehak NN; Cecco SA; Niemela JE; Elin RJ
    Clin Chem; 1997 Sep; 43(9):1595-600. PubMed ID: 9299939
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Measurement of free calcium ion in capillary blood and serum.
    Fogh-Andersen N; Christiansen TF; Komarmy L; Siggaard-Andersen O
    Clin Chem; 1978 Sep; 24(9):1545-52. PubMed ID: 28859
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Determination of serum ionised calcium by ion-exchange electrode in normal subjects.
    Conceicao SC; Ward MK; Alvarez-Ude F; Aljama P; Smith P; Kerr DN
    Clin Chim Acta; 1978 Jun; 86(2):143-51. PubMed ID: 657537
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Factors affecting the determination of ionized calcium in blood.
    Brauman J; Delvigne C; Deconinck I; Willems D
    Scand J Clin Lab Invest Suppl; 1983; 165():27-31. PubMed ID: 6578571
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Ca2+ measurement with ion selective electrodes. The French coordinated evaluation of seven analyzers, for a better clinical relevance and acceptance.
    Gouget B; Gourmelin Y; Blanchet F; Capolaghi B; Feuillu A; Lagente M; Lardet G; Manceaux JC; Pasquier C; Turret M
    Ann Biol Clin (Paris); 1988; 46(7):419-34. PubMed ID: 3056127
    [TBL] [Abstract][Full Text] [Related]  

  • 28. [The effect of the albumin concentration on the relation between the concentration of ionized calcium and total calcium in the blood of dogs].
    Mischke R; Hänies R; Lange K; Rivera Ramirez PA
    Dtsch Tierarztl Wochenschr; 1996 Jun; 103(6):199-204. PubMed ID: 8766900
    [TBL] [Abstract][Full Text] [Related]  

  • 29. In vivo continuous monitoring of ionized calcium in dogs using ion sensitive field effect transistors.
    McKinley BA; Wong KC; Janata J; Jordan WS; Westenskow DR
    Crit Care Med; 1981 Apr; 9(4):333-9. PubMed ID: 7214945
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Measurement of serum and plasma ionic calcium with the "Space-Stat 20 Ionized Calcium Analyzer".
    Husdan H; Leung M; Oreopoulos D; Rapoport A
    Clin Chem; 1977 Sep; 23(9):1775-7. PubMed ID: 890923
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Analytical evaluation of Kone Microlyte determination of ionized magnesium.
    van Ingen HE; Huijgen HJ; Kok WT; Sanders GT
    Clin Chem; 1994 Jan; 40(1):52-5. PubMed ID: 8287544
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Accuracy evaluation and hematocrit effect of commercial ionized calcium analyzers using Japanese serum reference material.
    Kuwa K; Tani W; Hayashi K; Umemoto M
    Scand J Clin Lab Invest Suppl; 1996; 224():173-7. PubMed ID: 8865433
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Apparent binding of ionized calcium by various buffers.
    Crowell JA; Bowers GN
    Clin Chem; 1985 Feb; 31(2):267-70. PubMed ID: 3967360
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Falsely high ionized magnesium results by an ion-selective electrode method in severe hypomagnesemia.
    Csako G; Rehak NN; Elin RJ
    Eur J Clin Chem Clin Biochem; 1997 Sep; 35(9):701-9. PubMed ID: 9352233
    [TBL] [Abstract][Full Text] [Related]  

  • 35. IFCC recommended reference method for the determination of the substance concentration of ionized calcium in undiluted serum, plasma or whole blood.
    Burnett RW; Christiansen TF; Covington AK; Fogh-Andersen N; Külpmann WR; Lewenstam A; Maas AHJ ; Müller-Plathe O; Sachs C; Andersen OS; VanKessel AL; Zijlstra WG;
    Clin Chem Lab Med; 2000 Dec; 38(12):1301-14. PubMed ID: 11205698
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Ionized calcium and magnesium: the effect of septic shock in the baboon.
    Trunkey D; Carpenter MA; Holcroft J
    J Trauma; 1978 Mar; 18(3):166-72. PubMed ID: 417190
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Measurement of ionized magnesium in whole blood, plasma and serum with a new ion-selective electrode in healthy and diseased human subjects.
    Altura BT; Altura BM
    Magnes Trace Elem; 1991-1992; 10(2-4):90-8. PubMed ID: 1844565
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Activity measurements of calcium, sodium, potassium, and chloride after equilibrium dialysis used to show lack of evidence for protein interference with calcium electrodes.
    Thode J; Boyd JC; Ladenson JH
    Clin Chem; 1987 Oct; 33(10):1811-3. PubMed ID: 3665034
    [TBL] [Abstract][Full Text] [Related]  

  • 39. A calcium clamp technique in man.
    Tørring O; Sjöberg HE
    Acta Physiol Scand; 1983 Dec; 119(4):387-92. PubMed ID: 6320587
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Ionized calcium and magnesium in the baboon: hemorrhagic shock and resuscitation.
    Carpenter MA; Trunkey DD; Holcroft J
    Circ Shock; 1978; 5(2):163-72. PubMed ID: 97031
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.