These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
324 related articles for article (PubMed ID: 7057845)
1. Ubiquitousness of Legionella pneumophila in the water supply of a hospital with endemic Legionnaires' disease. Stout J; Yu VL; Vickers RM; Zuravleff J; Best M; Brown A; Yee RB; Wadowsky R N Engl J Med; 1982 Feb; 306(8):466-8. PubMed ID: 7057845 [No Abstract] [Full Text] [Related]
2. [An epidemic of pneumonia caused by Legionella pneumophila in a Dutch hospital]. van Ketel RJ; Rietra PJ; Zanen-Lim OG; Zanen HC Ned Tijdschr Geneeskd; 1983 Feb; 127(8):324-7. PubMed ID: 6835415 [No Abstract] [Full Text] [Related]
3. Legionella contamination of hospital water supplies: monitoring of private healthcare facilities in Bologna, Italy. Legnani PP; Leoni E; Corradini N J Hosp Infect; 2002 Mar; 50(3):220-3. PubMed ID: 11886199 [TBL] [Abstract][Full Text] [Related]
4. Legionellaceae in the hospital water-supply. Epidemiological link with disease and evaluation of a method for control of nosocomial legionnaires' disease and Pittsburgh pneumonia. Best M; Yu VL; Stout J; Goetz A; Muder RR; Taylor F Lancet; 1983 Aug; 2(8345):307-10. PubMed ID: 6135832 [TBL] [Abstract][Full Text] [Related]
5. Persistence of Legionella in hospital water supplies and nosocomial Legionnaires' disease. Garcia-Nuñez M; Sopena N; Ragull S; Pedro-Botet ML; Morera J; Sabria M FEMS Immunol Med Microbiol; 2008 Mar; 52(2):202-6. PubMed ID: 18093139 [TBL] [Abstract][Full Text] [Related]
6. [Follow-up study of Legionella pneumophila pneumonia following the raising of the hot water temperature in a Dutch hospital]. van Ketel RJ; Rietra PJ; Zanen-Lim OG; van Keulen PH; Zanen HC Ned Tijdschr Geneeskd; 1986 Apr; 130(17):778-81. PubMed ID: 3713887 [No Abstract] [Full Text] [Related]
7. [Intra-amoebal development of Legionella pneumophila and the potential role of amoebae in the transmission of Legionnaires' disease]. Philippe C; Blech MF; Hartemann P Med Mal Infect; 2006 Apr; 36(4):196-200. PubMed ID: 16459041 [TBL] [Abstract][Full Text] [Related]
8. A recurrent outbreak of nosocomial legionnaires' disease detected by urinary antigen testing: evidence for long-term colonization of a hospital plumbing system. Lepine LA; Jernigan DB; Butler JC; Pruckler JM; Benson RF; Kim G; Hadler JL; Cartter ML; Fields BS Infect Control Hosp Epidemiol; 1998 Dec; 19(12):905-10. PubMed ID: 9872526 [TBL] [Abstract][Full Text] [Related]
9. [Management of the Legionella-link risk in a multicentre area's hospital: lessons learned of a six-year experience]. Lecointe D; Fagundez E; Pierron P; Musset JP; Brissé P; Vollereau D; Breton D; Théodora C; Beauvais R; Malbrunot C; Crine L; Fèvre C; Pathol Biol (Paris); 2010 Apr; 58(2):131-6. PubMed ID: 19875245 [TBL] [Abstract][Full Text] [Related]
10. [Outbreak of hospital acquired Legionnaires' disease in patients of ophthalmic ward. Nosocomial Legionella infections for the first time observed in Poland]. Stypułkowska-Misiurewicz H; Pancer K; Krogulska B; Matuszewska R Przegl Epidemiol; 2007; 61(4):657-65. PubMed ID: 18572497 [TBL] [Abstract][Full Text] [Related]
11. Legionnaires' disease outbreak in a haemodialysis unit. Bernat A; Garrigos E; Martin J; Moll R; Perez A Nephrol Dial Transplant; 1994; 9(2):217-8. PubMed ID: 8190344 [No Abstract] [Full Text] [Related]
12. Control of nosocomial Legionnaires' disease by keeping the circulating hot water temperature above 55 degrees C: experience from a 10-year surveillance programme in a district general hospital. Darelid J; Löfgren S; Malmvall BE J Hosp Infect; 2002 Mar; 50(3):213-9. PubMed ID: 11886198 [TBL] [Abstract][Full Text] [Related]
13. Colonization of a water system by Legionella organisms and nosocomial legionellosis: a 5-year report from a large Italian hospital. Ditommaso S; Biasin C; Giacomuzzi M; Zotti CM; Arione R; Guglielmi E; Barbaro S; Di Leo A; Serra R; Marchiaro G; Ruggenini Moiraghi A Infect Control Hosp Epidemiol; 2006 May; 27(5):532-5. PubMed ID: 16671043 [No Abstract] [Full Text] [Related]
14. [Relation between the water supply and the occurrence of Legionella infections]. Wan CQ Zhonghua Liu Xing Bing Xue Za Zhi; 1986 Feb; 7(1):58-60. PubMed ID: 3521886 [No Abstract] [Full Text] [Related]
15. [Active clinical surveillance for detection of Legionnaires' disease: implications for health care structures]. Marchesi I; Bargellini A; Cencetti S; Marchegiano P; Cauteruccio L; Casolari C; Borella P Ann Ig; 2007; 19(4):295-302. PubMed ID: 17937322 [TBL] [Abstract][Full Text] [Related]
16. Outbreak of Legionnaires' disease in a nursing home, Slovenia, August 2010: preliminary report. Trop Skaza A; Beskovnik L; Storman A; Ursic S; Groboljsek B; Kese D Euro Surveill; 2010 Sep; 15(39):19672. PubMed ID: 20929657 [TBL] [Abstract][Full Text] [Related]
17. [Another route of transmission in a Legionella pneumophila hospital infection]. Kaan JA Ned Tijdschr Geneeskd; 1986 Mar; 130(9):413-4. PubMed ID: 3960189 [No Abstract] [Full Text] [Related]
18. Legionella pneumophila in residential water supplies: environmental surveillance with clinical assessment for Legionnaires' disease. Stout JE; Yu VL; Yee YC; Vaccarello S; Diven W; Lee TC Epidemiol Infect; 1992 Aug; 109(1):49-57. PubMed ID: 1499672 [TBL] [Abstract][Full Text] [Related]