These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

81 related articles for article (PubMed ID: 7071369)

  • 41. Stiff fine-needle guide wire for catheterization and drainage.
    Cope C
    Radiology; 1983 Apr; 147(1):264. PubMed ID: 6828743
    [No Abstract]   [Full Text] [Related]  

  • 42. A simple device to prevent the accidental displacement of intrapleural drainage tubes.
    Tachakra SS
    Br J Clin Pract; 1976 Sep; 30(9):181. PubMed ID: 999781
    [No Abstract]   [Full Text] [Related]  

  • 43. Non-anastomotic biliary strictures following orthotopic liver transplantation: treatment with percutaneous transhepatic biliary drainage.
    Lu NN; Huang Q; Wang JF; Wei BJ; Gao K; Zhai RY
    Hepatogastroenterology; 2012; 59(120):2569-72. PubMed ID: 22591678
    [TBL] [Abstract][Full Text] [Related]  

  • 44. [Malignant biliary obstruction, general review and clinical practice].
    Bonnel D; André T; Mader B; Lefebvre JF; Bensoussan E; Liguory C
    Bull Cancer; 2013 May; 100(5):443-52. PubMed ID: 23644517
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Use of the Portner-Koolpe biliary biopsy catheter to facilitate double-guide-wire placement.
    Greenwood LH; Yrizarry JM; Brown SB; Clark CE
    AJR Am J Roentgenol; 1984 Mar; 142(3):543-4. PubMed ID: 6607643
    [No Abstract]   [Full Text] [Related]  

  • 46. Evaluation of flow characteristics of 3-way catheters.
    Manikandan R; Selvaratnam V; Philip J; Hanlon A; Machin DG; Williamson M
    J Urol; 2009 Apr; 181(4):1922-5. PubMed ID: 19237172
    [TBL] [Abstract][Full Text] [Related]  

  • 47. [A comparative multicenter study of the efficacy of single- and double-lumen catheter drainage].
    Niola R; D'Agostino H; Hoyt A; Romano L; Branstetter B; Rossi G; Oglevie S
    Radiol Med; 1996; 91(1-2):107-10. PubMed ID: 8614710
    [TBL] [Abstract][Full Text] [Related]  

  • 48. Percutaneous biliary drainage in patients with nondilated intrahepatic bile ducts.
    Funaki B; Zaleski GX; Straus CA; Leef JA; Funaki AN; Lorenz J; Farrell TA; Rosenblum JD
    AJR Am J Roentgenol; 1999 Dec; 173(6):1541-4. PubMed ID: 10584798
    [TBL] [Abstract][Full Text] [Related]  

  • 49. [Transformation of a percutaneous-transhepatic drainage method into a wide-lumen endoprosthesis by means of endoscopic implantation].
    Brambs HJ; Billmann P; Pausch J
    Schweiz Rundsch Med Prax; 1986 Mar; 75(10):266-7. PubMed ID: 3961336
    [No Abstract]   [Full Text] [Related]  

  • 50. Usefulness of transpapillary bile duct brushing cytology and forceps biopsy for improved diagnosis in patients with biliary strictures.
    Kitajima Y; Ohara H; Nakazawa T; Ando T; Hayashi K; Takada H; Tanaka H; Ogawa K; Sano H; Togawa S; Naito I; Hirai M; Ueno K; Ban T; Miyabe K; Yamashita H; Yoshimura N; Akita S; Gotoh K; Joh T
    J Gastroenterol Hepatol; 2007 Oct; 22(10):1615-20. PubMed ID: 17573833
    [TBL] [Abstract][Full Text] [Related]  

  • 51. Long-term intubation of the biliary tract with silastic catheters.
    Black HC; Hawk JC; Rambo WM
    Am Surg; 1971 Apr; 37(4):198-202. PubMed ID: 4996312
    [No Abstract]   [Full Text] [Related]  

  • 52. Percutaneous embolization of transhepatic tracks for biliary intervention.
    Lyon SM; Terhaar O; Given MF; O'Dwyer HM; McGrath FP; Lee MJ
    Cardiovasc Intervent Radiol; 2006; 29(6):1011-4. PubMed ID: 16823517
    [TBL] [Abstract][Full Text] [Related]  

  • 53. [Percutaneous transhepatic bile duct dilatation with a balloon catheter].
    Wolf KJ; Müller G
    Rofo; 1982 May; 136(5):600-3. PubMed ID: 6212513
    [No Abstract]   [Full Text] [Related]  

  • 54. Improving the efficiency of wound drainage catheters.
    Garcia-Rinaldi R; Defore WW; Green ZD; McBride C
    Am J Surg; 1975 Sep; 130(3):372-3. PubMed ID: 1166927
    [TBL] [Abstract][Full Text] [Related]  

  • 55. [Intestinal 2-channel polymer catheters].
    Larionova EK; Kirillov VV; Eliashevich BL
    Med Tekh; 1986; (3):55-7. PubMed ID: 3747786
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Modification of the Cope drainage catheter to facilitate placement.
    Berman HL; Bakal CW; Katz SG
    AJR Am J Roentgenol; 1986 Jan; 146(1):169-70. PubMed ID: 3484404
    [No Abstract]   [Full Text] [Related]  

  • 57. New device for permanent cannulation of the gallbladder, urinary bladder, stomach, and intestine of dogs. Applications in biological investigation.
    Zeman WV
    Surgery; 1966 Mar; 59(3):387-96. PubMed ID: 5906230
    [No Abstract]   [Full Text] [Related]  

  • 58. A new apparatus for catheter drainage.
    LIVERMORE GR
    Urol Cutaneous Rev; 1952 Feb; 56(2):79. PubMed ID: 14913823
    [No Abstract]   [Full Text] [Related]  

  • 59. Letter: Irrigation-sump drain.
    Fuller JW
    Surgery; 1976 Feb; 79(02):240. PubMed ID: 1246682
    [No Abstract]   [Full Text] [Related]  

  • 60. An improved sump drain-irrigation device of simple construction.
    Tribble DE
    Arch Surg; 1972 Sep; 105(3):511-3. PubMed ID: 5056949
    [No Abstract]   [Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 5.