These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

67 related articles for article (PubMed ID: 7078007)

  • 1. [Notes on clinical criteria for the evaluation of tonometers (author's transl)].
    Jessen K; Hoffmann F
    Klin Monbl Augenheilkd; 1982 Jan; 180(1):96-9. PubMed ID: 7078007
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The accuracy of continued clinical use of goldmann applanation tonometers with known calibration errors.
    Sandhu SS; Chattopadhyay S; Amariotakis GA; Skarmoutsos F; Birch MK; Ray-Chaudhuri N
    Ophthalmology; 2009 Jan; 116(1):9-13. PubMed ID: 18801579
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [The safety of metrological control of applanation tonometers by technical investigations on transfer standards].
    Schwenteck T; Thiemich HJ
    Klin Monbl Augenheilkd; 2010 Jun; 227(6):489-95. PubMed ID: 20349398
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Current status of the standardization of air impulse tonometers and their evaluation--as an example: the Non-Contact Tonometer II].
    Jessen K; Hoffmann F
    Klin Monbl Augenheilkd; 1983 Oct; 183(4):296-300. PubMed ID: 6645276
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Intraocular pressure difference in Goldmann applanation tonometry versus Perkins hand-held applanation tonometry in overweight patients.
    dos Santos MG; Makk S; Berghold A; Eckhardt M; Haas A
    Ophthalmology; 1998 Dec; 105(12):2260-3. PubMed ID: 9855157
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Tonometer calibration (author's transl)].
    Weigelin E; Jessen K
    Klin Monbl Augenheilkd; 1981 Jul; 179(1):1-12. PubMed ID: 7278067
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Comparison of three tonometers for measuring intraocular pressure in rabbits.
    Abrams LS; Vitale S; Jampel HD
    Invest Ophthalmol Vis Sci; 1996 Apr; 37(5):940-4. PubMed ID: 8603880
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The Proview phosphene tonometer fails to measure ocular pressure accurately in clinical practice.
    Alvarez TL; Gollance SA; Thomas GA; Greene RJ; Marchetto PM; Moore EJ; Realini T; Liebmann JM; Ritch R; Lama P; Fechtner RD
    Ophthalmology; 2004 Jun; 111(6):1077-85. PubMed ID: 15177956
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Maintenance of measuring quality of transfer standards for the metrological control of air impulse tonometers].
    Schwenteck T; Thiemich HJ
    Klin Monbl Augenheilkd; 2007 Mar; 224(3):167-72. PubMed ID: 17385116
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [The American Optical non-contact tonometer and its results compared with the Goldmann applanation tonometer (author's transl)].
    Derka H
    Klin Monbl Augenheilkd; 1980 Nov; 177(5):634-42. PubMed ID: 7253520
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Comparison of the use of new handheld tonometers and established applanation tonometers in dogs.
    Görig C; Coenen RT; Stades FC; Djajadiningrat-Laanen SC; Boevé MH
    Am J Vet Res; 2006 Jan; 67(1):134-44. PubMed ID: 16426223
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Clinical evaluation of a new tonometer on the basis of international standard ISO 8612].
    Schwenteck T; Harnisch JP; Galanski M; Draeger J
    Klin Monbl Augenheilkd; 2006 Oct; 223(10):808-12. PubMed ID: 17063422
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Comparison of Goldmann applanation tonometry and dynamic contour tonometry in healthy and glaucomatous eyes.
    Ceruti P; Morbio R; Marraffa M; Marchini G
    Eye (Lond); 2009 Feb; 23(2):262-9. PubMed ID: 18219335
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Agreement of rebound tonometer in measuring intraocular pressure with three types of applanation tonometers.
    Nakamura M; Darhad U; Tatsumi Y; Fujioka M; Kusuhara A; Maeda H; Negi A
    Am J Ophthalmol; 2006 Aug; 142(2):332-4. PubMed ID: 16876523
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Legal calibration of ocular tonometers].
    Jessen K
    Klin Monbl Augenheilkd; 1991 Nov; 199(5):372-3. PubMed ID: 1787665
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Comparison of the rebound tonometer (ICare) to the applanation tonometer (Tonopen XL) in normotensive dogs.
    Leiva M; Naranjo C; Peña MT
    Vet Ophthalmol; 2006; 9(1):17-21. PubMed ID: 16409240
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Intraocular pressure and pulse rate measurements by the OBF tonograph--comparison to reference instruments.
    Yang YC; Illango B; Cook A; Batterbury M
    Ophthalmic Physiol Opt; 2000 Sep; 20(5):401-7. PubMed ID: 11045249
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Evaluation of two applanation tonometers in horses.
    Miller PE; Pickett JP; Majors LJ
    Am J Vet Res; 1990 Jun; 51(6):935-7. PubMed ID: 2368953
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Three portable tonometers, the TGDc-01, the ICARE and the Tonopen XL, compared with each other and with Goldmann applanation tonometry*.
    van der Jagt LH; Jansonius NM
    Ophthalmic Physiol Opt; 2005 Sep; 25(5):429-35. PubMed ID: 16101949
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Comparison of dynamic contour tonometry and goldmann applanation tonometry in deep lamellar and penetrating keratoplasties.
    Ceruti P; Morbio R; Marraffa M; Marchini G
    Am J Ophthalmol; 2008 Feb; 145(2):215-221. PubMed ID: 18222191
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 4.