These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

130 related articles for article (PubMed ID: 708287)

  • 21. [Intra-aortic balloon pump. Preliminary experiences in clinical use].
    Froysaker T; Kveim M; Lilleaasen P; Hall KV; Efskind L
    Tidsskr Nor Laegeforen; 1974 Dec; 94(34-36):2377-80. PubMed ID: 4446011
    [No Abstract]   [Full Text] [Related]  

  • 22. Femorofemoral bypass for temporary cardiac support in heart surgery.
    Winton TL; Salerno TA
    Can J Surg; 1983 Sep; 26(5):465-8. PubMed ID: 6616366
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Counterpulsation with a new pulsatile assist device (PAD) in open-heart surgery.
    Bregman D; Parodi EN; Haubert SM; Szarnicki R; Spotnitz HM; Bowman FO; Reemtsma K; Malm JR
    Med Instrum; 1976; 10(5):232-8. PubMed ID: 967071
    [TBL] [Abstract][Full Text] [Related]  

  • 24. A new type of mechanical heart assistance: a combined pump for bypass and counterpulsation.
    Vasků J; Bednarík B; Urbánek E; Andreovský F; Perestý S; Dolezel S; Korístek V
    Trans N Y Acad Sci; 1972 Jan; 34(1):58-83. PubMed ID: 4502031
    [No Abstract]   [Full Text] [Related]  

  • 25. Complete left ventricular bypass with a paracorporeal pump: design and evaluation.
    Pierce WS; Brighton JA; O'Bannon W; Donachy JH; Phillips WM; Landis DL; White WJ; Waldhausen JA
    Ann Surg; 1974 Oct; 180(4):418-26. PubMed ID: 4547165
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Outcomes after implantation of partial-support left ventricular assist devices in inotropic-dependent patients: Do we still need full-support assist devices?
    Sabashnikov A; Popov AF; Bowles CT; Mohite PN; Weymann A; Hards R; Hedger M; Wittwer T; Wippermann J; Wahlers T; Schoendube FA; Simon AR
    J Thorac Cardiovasc Surg; 2014 Sep; 148(3):1115-21; discussion 1021-2. PubMed ID: 25129605
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Temporary mechanical support of left ventricular failure following open heart surgery.
    Litwak RS; Lukban SB; Jurado RA; Koffsky RM; Ortiz AF; grana VP; Fischer AP; Sherman J
    Adv Cardiol; 1977; 20():102-9. PubMed ID: 848381
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Methods of acute postcardiotomy left ventricular assistance.
    Reardon MJ; Conklin LD; Letsou GV; Safi HJ; Espada R; Baldwin JC
    J Cardiovasc Surg (Torino); 1999 Oct; 40(5):627-31. PubMed ID: 10596993
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Initial clinical experience with a new temporary left ventricular assist device.
    Golding LR; Groves LK; Peter M; Jacobs G; Sukalac R; Nosé Y; Loop FD
    Ann Thorac Surg; 1980 Jan; 29(1):66-9. PubMed ID: 6965444
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Clinical and hemodynamic criteria for use of the intra-aortic balloon pump in patients requiring cardiac surgery.
    Bolooki H; Williams W; Thurer RJ; Vargas A; Kaiser GA; Mack F; Ghahramani AR
    J Thorac Cardiovasc Surg; 1976 Nov; 72(5):756-68. PubMed ID: 979316
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Circulatory support in infants with post-cardiopulmonary bypass left ventricular dysfunction using a left ventricular assist device.
    Moat NE; Pawade A; Lewis BC; Shore G; Lamb RK; Monro JJ
    Eur J Cardiothorac Surg; 1990; 4(12):649-52. PubMed ID: 2288745
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Successful use of a paracorporeal left ventricular assist device in man.
    Berger RL; McCormick JR; Stetz JD; Klein MD; Ryan TJ; Carr J; Sweet S; Bernhard WF
    JAMA; 1980 Jan; 243(1):46-9. PubMed ID: 7350338
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Support of the myocardium with intra-aortic balloon counterpulsation following cardiopulmonary bypass.
    Stewart S; Biddle T; DeWeese J
    J Thorac Cardiovasc Surg; 1976 Jul; 72(1):109-14. PubMed ID: 1084446
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Development and evaluation of pulsatile roller pump and tubing for cardiac assistance.
    Noon GP; Harrell JE; Feldman L; Peterson J; Kent PM; DeBakey ME
    Artif Organs; 1983 Feb; 7(1):49-54. PubMed ID: 6838406
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Clinical experience with bypass of the left ventricle using a roller pump.
    Lokshin L; Osipov V; Khodas M; Shabalkin V; Cherepenin L; Mikhailov Iu; Arsenev S; Leonova S; Rogov K; Ivanov V
    Artif Organs; 1987 Feb; 11(1):11-5. PubMed ID: 3566577
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Technique and results with a roller pump left and right heart assist device.
    Rose DM; Connolly M; Cunningham JN; Spencer FC
    Ann Thorac Surg; 1989 Jan; 47(1):124-9. PubMed ID: 2912390
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Mechanical circulatory assist using heparin-coated tube and roller pump system.
    Saito A; Hayashi J; Eguchi S
    Ann Thorac Surg; 1992 Apr; 53(4):659-65. PubMed ID: 1554278
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Extracorporeal life support in neonates, infants, and children after repair of congenital heart disease: modern era results in a single institution.
    Alsoufi B; Shen I; Karamlou T; Giacomuzzi C; Burch G; Silberbach M; Ungerleider R
    Ann Thorac Surg; 2005 Jul; 80(1):15-21; discussion 21. PubMed ID: 15975332
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Mechanical control of circulation: clinical results with intra-aortic balloon pumping and veno-arterial bypass in left and/or right cardiac failure.
    Hirose H; Matsuda H; Kawashima Y
    Jpn Circ J; 1984 Mar; 48(3):288-94. PubMed ID: 6608593
    [TBL] [Abstract][Full Text] [Related]  

  • 40. The role of mechanical devices.
    Cohn LH
    J Card Surg; 1990 Sep; 5(3 Suppl):278-81. PubMed ID: 2133857
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.