These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

167 related articles for article (PubMed ID: 7085963)

  • 1. Percutaneous intraaortic balloon pumping: initial experience.
    Gonzalez M; Installé E; Trémouroux J
    Intensive Care Med; 1982; 8(3):143-7. PubMed ID: 7085963
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Percutaneous intraaortic balloon pumping: initial clinical experience.
    Bregman D; Casarella WJ
    Ann Thorac Surg; 1980 Feb; 29(2):153-5. PubMed ID: 7356366
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Percutaneous intraaortic balloon insertion.
    Bregman D; Nichols AB; Weiss MB; Powers ER; Martin EC; Casarella WJ
    Am J Cardiol; 1980 Aug; 46(2):261-4. PubMed ID: 7405838
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Care of the patient on the percutaneous intra-aortic counterpulsation balloon.
    Bullas JB
    Crit Care Nurse; 1982; 2(4):40-9. PubMed ID: 6925516
    [No Abstract]   [Full Text] [Related]  

  • 5. Intra-aortic balloon pumping in the elderly: percutaneous versus surgical catheter insertion.
    Di Bari M; De Alfieri W; Greppi B; Conti A; Ferrucci L; Calamandrei M; Vannucci A; Pini R; Menegatti G; Vassanelli C
    Eur Heart J; 1984 Mar; 5(3):222-6. PubMed ID: 6723691
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Guidelines for effective and safe percutaneous intraaortic balloon pump insertion and removal.
    Vignola PA; Swaye PS; Gosselin AJ
    Am J Cardiol; 1981 Oct; 48(4):660-4. PubMed ID: 7282548
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Percutaneous intraaortic balloon counterpulsation. Clinical effectiveness and hazards.
    Hauser AM; Gordon S; Gangadharan V; Ramos RG; Westveer DC; Garg AK; Timmis GC
    Chest; 1982 Oct; 82(4):422-5. PubMed ID: 7116960
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Percutaneous vs surgical placement of intra-aortic balloon assist.
    Singh AK; Williams DO; Cooper GN; Riley RS; Karlson KE
    Cathet Cardiovasc Diagn; 1982; 8(5):519-23. PubMed ID: 7139705
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Direct ascending aortic insertion of the "percutaneous" intraaortic balloon catheter in the open chest: advantages and precautions.
    Bonchek LI; Olinger GN
    Ann Thorac Surg; 1981 Nov; 32(5):512-4. PubMed ID: 6975608
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Simplified technique for intraaortic balloon insertion.
    Zada F; McCabe JC; Subramanian VA
    Ann Thorac Surg; 1980 Jun; 29(6):573-4. PubMed ID: 7387252
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Percutaneous intraaortic balloon insertion in patients with aortoiliac disease.
    Nichols AB; Weiss MB; Casarella WJ; Bregman D
    Cathet Cardiovasc Diagn; 1981; 7(4):443-9. PubMed ID: 7326740
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Complications of ascending aortic intraaortic balloon pump cannulation.
    Meldrum-Hanna WG; Deal CW; Ross DE
    Ann Thorac Surg; 1985 Sep; 40(3):241-4. PubMed ID: 4037916
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Assisted circulation by intra-aortic balloon pumping].
    Ponomareva LI; Mordashev BK
    Kardiologiia; 1982 Oct; 22(10):122-6. PubMed ID: 6757521
    [No Abstract]   [Full Text] [Related]  

  • 14. Comparison of wire-guided percutaneous insertion and conventional surgical insertion of intra-aortic balloon pumps in 151 patients.
    Alcan KE; Stertzer SH; Wallsh E; Franzone AJ; Bruno MS; DePasquale NN
    Am J Med; 1983 Jul; 75(1):24-8. PubMed ID: 6859082
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Percutaneous wire-guided balloon pumping.
    Leinbach RC; Goldstein J; Gold HK; Moses JW; Collins MB; Subramanian V
    Am J Cardiol; 1982 May; 49(7):1707-10. PubMed ID: 7081056
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Mechanical techniques of circulation support: a percutaneous intra-aortic balloon device.
    Bregman D; Cohen SR
    Artif Organs; 1983 Feb; 7(1):38-48. PubMed ID: 6340645
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A new percutaneous intra-aortic balloon.
    Bregman D
    Trans Am Soc Artif Intern Organs; 1980; 26():8-11. PubMed ID: 7245564
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Technique for removal of percutaneously placed intraaortic balloons.
    Rodigas PC; Finnegan JO
    Ann Thorac Surg; 1985 Jul; 40(1):80-1. PubMed ID: 3893340
    [No Abstract]   [Full Text] [Related]  

  • 19. Modification of intraaortic balloon catheter to permit introduction by cardiac catheterization techniques.
    Wolfson S; Karsh DL; Langou RA; Geha AS; Hammond GL; Cohen LS
    Am J Cardiol; 1978 Apr; 41(4):733-8. PubMed ID: 645579
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Improved technique of intraaortic balloon insertion.
    Merrill JR; McClusky D; Logan WD
    Ann Thorac Surg; 1978 Sep; 26(3):261-2. PubMed ID: 752293
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.