1. Evaluation of three minicolumn procedures for measuring hemoglobin A1.
Hammons GT; Junger K; McDonald JM; Ladenson JH
Clin Chem; 1982 Aug; 28(8):1775-8. PubMed ID: 7094299
[TBL] [Abstract][Full Text] [Related]
2. Improvements in hemoglobin AI determination by rapid cation-exchange chromatography.
Rand PG; Nelson C
Clin Chem; 1980 Jul; 26(8):1209-12. PubMed ID: 7389094
[TBL] [Abstract][Full Text] [Related]
3. Comparison of four commercial methods for the determination of fast hemoglobins.
Lee LP; Arnott B; Feng M; Hynie I
Clin Biochem; 1982 Aug; 15(4):230-3. PubMed ID: 7127729
[TBL] [Abstract][Full Text] [Related]
4. An automated liquid-chromatographic system for convenient determination of glycated hemoglobin A1c.
Saleh AK; Moussa MA
Clin Chem; 1985 Nov; 31(11):1872-6. PubMed ID: 4053357
[TBL] [Abstract][Full Text] [Related]
5. Comparison of column chromatographic, colorimetric and electrophoretic methods for determination of glycosylated hemoglobin (HbA1).
Yatscoff RW; Braidwood JL
Clin Biochem; 1982 Dec; 15(6):302-7. PubMed ID: 7168892
[TBL] [Abstract][Full Text] [Related]
6. Glycosylated hemoglobin in the diagnosis of non-insulin-dependent diabetes mellitus.
Kesson CM; Young RE; Talwar D; Whitelaw JW; Robb DA
Diabetes Care; 1982; 5(4):395-8. PubMed ID: 7151656
[TBL] [Abstract][Full Text] [Related]
7. Temperature dependence of the chromatographic assay of hemoglobin A1 and application of a temperature controlled assay to clinical evaluation of diabetic control.
Johnson MW; Dobrea GM; Bendezu R; Wieland RG
Clin Chim Acta; 1980 Jul; 104(3):319-28. PubMed ID: 7389141
[TBL] [Abstract][Full Text] [Related]
8. Comparison of six assays for glycosylated haemoglobin determination.
Mortensen HB; Nielsen L; Søegaard U; Svendsen PA; Nerup J
Scand J Clin Lab Invest; 1983 Sep; 43(5):357-62. PubMed ID: 6648320
[TBL] [Abstract][Full Text] [Related]
9. Glycated hemoglobin fractions in normal and diabetic dogs measured by high performance liquid chromatography.
Hasegawa S; Sako T; Takemura N; Koyama H; Motoyoshi S
J Vet Med Sci; 1991 Feb; 53(1):65-8. PubMed ID: 1830782
[TBL] [Abstract][Full Text] [Related]
10. New spectrophotometric method for the determination of hemoglobin A1 compared with a microcolumn technique.
Wålinder O; Ronquist G; Fager PJ
Clin Chem; 1982 Jan; 28(1):96-9. PubMed ID: 7055944
[TBL] [Abstract][Full Text] [Related]
11. [Evaluation of three commercial kits for the estimation of total glycolysed hemoglobin: Hb Al (author's transl)].
Rosa J; Senan C; Blouquit Y; Garel MC; Molko F
Ann Biol Clin (Paris); 1980; 38(3):183-9. PubMed ID: 6778265
[TBL] [Abstract][Full Text] [Related]
12. Comparison of hemoglobin A1c and hemoglobin A1 in diabetic patients.
James TM; Davis JE; McDonald JM; Santiago JV; Ladenson JH
Clin Biochem; 1981 Feb; 14(1):25-7. PubMed ID: 7237739
[TBL] [Abstract][Full Text] [Related]
13. The narrow therapeutic window of glycated hemoglobin and assay variability.
Hosseini SS; Bibler I; Charles MA
Metabolism; 1999 Dec; 48(12):1498-502. PubMed ID: 10599979
[TBL] [Abstract][Full Text] [Related]
14. HbA1 determination by agar gel electrophoresis after elimination of labile HbA1: a comparison with ion-exchange chromatography.
Dahl-Jørgensen K; Larsen AE
Scand J Clin Lab Invest; 1982 Feb; 42(1):27-33. PubMed ID: 7134788
[TBL] [Abstract][Full Text] [Related]
15. Effects of sickle cell trait and hemoglobin C trait on determinations of HbA1c by an immunoassay method.
Roberts WL; McCraw M; Cook CB
Diabetes Care; 1998 Jun; 21(6):983-6. PubMed ID: 9614618
[TBL] [Abstract][Full Text] [Related]
16. Glycated haemoglobin values: problems in assessing blood glucose control in diabetes mellitus.
Kilpatrick ES; Rumley AG; Dominiczak MH; Small M
BMJ; 1994 Oct; 309(6960):983-6. PubMed ID: 7950717
[TBL] [Abstract][Full Text] [Related]
17. Three chromatographic methods compared for measurement of hemoglobin A1 and A1c.
Rowe DJ; Goodland FC
Clin Chem; 1984 Jan; 30(1):156-7. PubMed ID: 6690130
[No Abstract] [Full Text] [Related]
18. Two commercial methods evaluated for eliminating the labile fraction from the assay for glycated hemoglobin (glycohemoglobin).
Nathan DM; Dunn BS; Francis TB
Clin Chem; 1984 Jan; 30(1):109-10. PubMed ID: 6690111
[TBL] [Abstract][Full Text] [Related]
19. Analytical evaluation of hemoglobin A(1c) dual kit assay on Bio-Rad Variant II: an automated HPLC hemoglobin analyzer for the management of diabetic patients.
Moridani MY; Verjee Z; Allen LC
Clin Biochem; 2003 Jun; 36(4):317-20. PubMed ID: 12810162
[TBL] [Abstract][Full Text] [Related]
20. Haemoglobinopathies: a pitfall in the assessment of glycosylated haemoglobin by ion-exchange chromatography.
Eberentz-Lhomme C; Ducrocq R; Intrator S; Elion J; Nunez E; Assan R
Diabetologia; 1984 Dec; 27(6):596-8. PubMed ID: 6530054