These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
27. Determination of urinary urate with alkylamine glass-bound uricase. Pundir CS; Bhargava AK; Gupta R Indian J Biochem Biophys; 2000 Apr; 37(2):140-2. PubMed ID: 10983426 [No Abstract] [Full Text] [Related]
28. Comparison of four methods for measuring uric acid: copper-chelate, phosphotungstate, manual uricase, and automated kinetic uricase. Lum G; Gambino SR Clin Chem; 1973 Oct; 19(10):1184-6. PubMed ID: 4741958 [No Abstract] [Full Text] [Related]
29. [Uric acid determination in dilute serum with an enzyme electrochemical and enzyme-free sensor]. Jänchen M; Walzel G; Neef B; Wolf B; Scheller F; Kühn M; Pfeiffer D; Sojka W; Jaross W Biomed Biochim Acta; 1983; 42(9):1055-65. PubMed ID: 6670996 [TBL] [Abstract][Full Text] [Related]
30. The use of immobilized enzyme reactors in continuous-flow analyzers for the determination of glucose, urea, and uric acid. Chirillo R; Caenaro G; Pavan B; Pin A Clin Chem; 1979 Oct; 25(10):1744-8. PubMed ID: 476924 [TBL] [Abstract][Full Text] [Related]
31. Construction of amperometric uric acid biosensor based on uricase immobilized on PBNPs/cMWCNT/PANI/Au composite. Rawal R; Chawla S; Chauhan N; Dahiya T; Pundir CS Int J Biol Macromol; 2012 Jan; 50(1):112-8. PubMed ID: 22020190 [TBL] [Abstract][Full Text] [Related]
32. Immobilized-enzyme membrane sandwich reactor used in automated micro-scale assay of plasma uric acid. Kamoun P; Douay O Clin Chem; 1978 Nov; 24(11):2033-5. PubMed ID: 709842 [TBL] [Abstract][Full Text] [Related]
33. Improvements of the uricase-u.v. method for the determination of uric acid in serum and urine. Klein F; Lafeber GJ Clin Chim Acta; 1966 Nov; 14(5):708-10. PubMed ID: 5972422 [No Abstract] [Full Text] [Related]
34. Four methods for determining uric acid compared with a candidate reference method. Elin RJ; Johnson E; Chesler R Clin Chem; 1982 Oct; 28(10):2098-100. PubMed ID: 7127737 [TBL] [Abstract][Full Text] [Related]
35. Effect of paracetamol on uric acid determination. Wilding P; Heath DA Ann Clin Biochem; 1975 Jul; 12(4):142-4. PubMed ID: 15637909 [TBL] [Abstract][Full Text] [Related]
36. Use of 3,5-dichloro-2-hydroxybenzenesulfonic acid/4-aminophenazone chromogenic system in direct enzymic assay of uric acid in serum and urine. Fossati P; Prencipe L; Berti G Clin Chem; 1980 Feb; 26(2):227-31. PubMed ID: 7353268 [TBL] [Abstract][Full Text] [Related]
37. An amperometric biosensor for uric acid determination prepared from uricase immobilized in polypyrrole film. Cete S; Yaşar A; Arslan F Artif Cells Blood Substit Immobil Biotechnol; 2006; 34(3):367-80. PubMed ID: 16809136 [TBL] [Abstract][Full Text] [Related]
38. Effect of limitation of protein intake on hepatic uricase and on urinary uric acid and allantoin. ESTES FL; WAINIO WW; ALLISON JB Proc Soc Exp Biol Med; 1955 Aug; 89(4):619-21. PubMed ID: 13254845 [No Abstract] [Full Text] [Related]
39. Hyperxanthinemia interferes with serum uric acid determinations by the uricase method. Hande KR; Perini F; Putterman G; Elin R Clin Chem; 1979 Aug; 25(8):1492-4. PubMed ID: 455692 [TBL] [Abstract][Full Text] [Related]
40. Immobilization of uricase within polystyrene using polymaleimidostyrene as a stabilizer and its application to uric acid sensor. Wang X; Hagiwara T; Uchiyama S Anal Chim Acta; 2007 Mar; 587(1):41-6. PubMed ID: 17386751 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]