These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

124 related articles for article (PubMed ID: 7114051)

  • 1. Osmotic error in erythrocyte volume determinations.
    Beautyman W; Bills T
    Am J Hematol; 1982 Jun; 12(4):383-9. PubMed ID: 7114051
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Hypo- and hypernatremia results in inaccurate erythrocyte mean corpuscular volume measurement in vitro, when using Sysmex XE 2100.
    Philipsen JP; Madsen KV
    Scand J Clin Lab Invest; 2015 Nov; 75(7):588-94. PubMed ID: 26305422
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Evidence for hyperglycemic osmotic matrix effects on the Comprehensive Hematology Survey 1981-1982.
    Savage RA
    Am J Clin Pathol; 1983 Oct; 80(4 Suppl):626-32. PubMed ID: 6624730
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Interference of serum tonicity with the measurement of red cell mean corpuscular volume.
    Decaux G; Efira A; Dhaene M; Unger J
    Acta Haematol; 1982; 67(1):62-6. PubMed ID: 6800203
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Nonequivalence of automated and manual hematocrit and erythrocytic indices.
    Fairbanks VF
    Am J Clin Pathol; 1980 Jan; 73(1):55-62. PubMed ID: 7352424
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Approach to and management of abnormalities in plasma sodium.
    Decaux G
    Acta Clin Belg; 2019 Feb; 74(1):7-20. PubMed ID: 30311550
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Sodium.
    Janz T
    Emerg Med Clin North Am; 1986 Feb; 4(1):115-30. PubMed ID: 3512240
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Hematology and erythrocyte osmotic fragility of the Franquet's fruit bat (Epomops franqueti).
    Ekeolu OK; Adebiyi OE
    J Basic Clin Physiol Pharmacol; 2018 Jul; 29(4):391-394. PubMed ID: 29543589
    [TBL] [Abstract][Full Text] [Related]  

  • 9. The mean red cell volume in long distance runners.
    Stäubli M; Roessler B
    Eur J Appl Physiol Occup Physiol; 1986; 55(1):49-53. PubMed ID: 3698987
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Effect of osmolality on erythrocyte rheology and perfusion of an artificial microvascular network.
    Reinhart WH; Piety NZ; Goede JS; Shevkoplyas SS
    Microvasc Res; 2015 Mar; 98():102-7. PubMed ID: 25660474
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Quantitative analysis of the dysnatremias.
    Ring T
    Kidney Int; 2006 Jan; 69(2):416. PubMed ID: 16408136
    [No Abstract]   [Full Text] [Related]  

  • 12. Characteristics, symptoms, and outcome of severe dysnatremias present on hospital admission.
    Arampatzis S; Frauchiger B; Fiedler GM; Leichtle AB; Buhl D; Schwarz C; Funk GC; Zimmermann H; Exadaktylos AK; Lindner G
    Am J Med; 2012 Nov; 125(11):1125.e1-1125.e7. PubMed ID: 22939097
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Interference of hyperleukocytosis on Coulter Counter Model S blood counts: methods for correction.
    Seigneurin D; Passe D
    Biomed Pharmacother; 1983; 37(8):401-4. PubMed ID: 6667345
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [The hematological laboratory of clinical practice].
    Bürgi W
    Ther Umsch; 1995 May; 52(5):334-9. PubMed ID: 7770819
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Mathematical correction of the invitro storage--related increase in erythrocyte mean cell volume of an automated hematology analyzer--the Cell-Dyn 4000.
    Huisman A; Stokwielder R; van Solinge WW
    Lab Hematol; 2004; 10(2):68-73. PubMed ID: 15224762
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Evaluation of complete blood count results from a new, on-site hemocytometer compared with a laboratory-based hemocytometer.
    Despotis GJ; Alsoufiev A; Hogue CW; Zoys TN; Goodnough LT; Santoro SA; Kater KM; Barnes P; Lappas DG
    Crit Care Med; 1996 Jul; 24(7):1163-7. PubMed ID: 8674329
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Spurious elevation of the electronically determined mean corpuscular volume and hematocrit caused by hyperglycemia.
    Holt JT; DeWandler MJ; Arvan DA
    Am J Clin Pathol; 1982 May; 77(5):561-7. PubMed ID: 7081150
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Real and artefactual erythrocyte swelling in hyperglycaemia.
    Bock HA; Flückiger R; Berger W
    Diabetologia; 1985 Jun; 28(6):335-8. PubMed ID: 4043577
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The erythrocyte ghost is a perfect osmometer.
    Kwant WO; Seeman P
    J Gen Physiol; 1970 Feb; 55(2):208-19. PubMed ID: 5413078
    [TBL] [Abstract][Full Text] [Related]  

  • 20. The Impact of a Standardized Sodium Protocol on Incidence and Outcome of Dysnatremias in Neurocritical Care.
    Spatenkova V; Bradac O; Skrabalek P
    J Neurol Surg A Cent Eur Neurosurg; 2015 Jul; 76(4):279-90. PubMed ID: 25539069
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.