BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

141 related articles for article (PubMed ID: 7118290)

  • 1. Leucocyte occlusion of cuprophane membranes as a cause of reduced hemodialysis efficiency.
    Dodd NJ; Parsons V; Weston MJ
    Int J Artif Organs; 1982 Jul; 5(4):275-6. PubMed ID: 7118290
    [No Abstract]   [Full Text] [Related]  

  • 2. Cellulose membranes--time for a change?
    Henderson LW; Chenoweth DE
    Contrib Nephrol; 1985; 44():112-26. PubMed ID: 3872769
    [No Abstract]   [Full Text] [Related]  

  • 3. Effect of dialyzer geometry during hemodialysis with cuprophane membranes.
    Taylor JE; McLaren M; Mactier RA; Henderson IS; Stewart WK; Belch JJ
    Kidney Int; 1992 Aug; 42(2):442-7. PubMed ID: 1405328
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Biocompatibility of dialysis membranes: effects of chronic complement activation.
    Hakim RM; Fearon DT; Lazarus JM
    Kidney Int; 1984 Aug; 26(2):194-200. PubMed ID: 6334194
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Preliminary report on complement activating potential of polycarbonate membrane.
    Henderson LW; Chenoweth DE; Shinaberger JH; Miller J; Konstantin P
    Blood Purif; 1986; 4(1-3):74-81. PubMed ID: 3730164
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Increases in circulating level of platelet-activating factor lag behind transient neutropenia during hemodialysis with cuprophane membranes.
    Sakaguchi K; Morimoto S; Chen YH; Nakamoto Y; Ogihara T
    Nephron; 1991; 59(3):455-60. PubMed ID: 1758537
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Cellulose acetate and cuprophane for hemodialysis: effects on protein catabolic rate.
    Robles NR; Gomez-Ainsua C; Cruz A
    Nephron; 1995; 70(4):508-9. PubMed ID: 7477664
    [No Abstract]   [Full Text] [Related]  

  • 8. Patient reactions and granulocyte degranulation during hemodialysis with cuprophane and polycarbonate membranes. A double-blind study.
    Danielson BG; Hällgren R; Venge P
    Blood Purif; 1986; 4(1-3):147-50. PubMed ID: 3524607
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Immediate effect of hemodialysis with cuprophane membrane and acetate containing dialysis fluid on respiratory function in patients with chronic renal failure].
    Wanic-Kossowska M
    Pol Tyg Lek; 1993 Feb 15-22; 48(7-8):175-7. PubMed ID: 8415262
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Cuprophan membrane induces interleukin-1 activity.
    Yamagami S; Yoshihara H; Kishimoto T; Sugimura T; Niwa M; Maekawa M
    ASAIO Trans; 1986; 32(1):98-101. PubMed ID: 3490869
    [No Abstract]   [Full Text] [Related]  

  • 11. Evolution of serum prealbumin following hemodialysis: effect of different dialysis membranes.
    Docci D; Bilancioni R; Pistocchi E; Baldrati L; Capponcini C; Delvecchio C; Feletti C
    Nephron; 1992; 62(2):145-9. PubMed ID: 1436305
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Biocompatibility of hemodialysis using cuprophane membranes.
    Rommes JH; Sangster B; Borst C; Daha MR; van Heijst NP
    Vet Hum Toxicol; 1987 Aug; 29(4):293-9. PubMed ID: 3629907
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Clinical sequelae of complement activation in hemodialysis.
    Hakim RM
    Clin Nephrol; 1986; 26 Suppl 1():S9-12. PubMed ID: 3829474
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Biocompatibility and hemodynamic studies during polycarbonate versus cuprophane membrane dialysis.
    Schohn DC; Jahn HA; Eber M; Hauptmann G
    Blood Purif; 1986; 4(1-3):102-11. PubMed ID: 3730154
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Biocompatibility of different hemodialysis membranes: activation of complement and leukopenia.
    Wegmüller E; Montandon A; Nydegger U; Descoeudres C
    Int J Artif Organs; 1986 Mar; 9(2):85-92. PubMed ID: 3699914
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Animal models to study the cardiopulmonary effects of artificial kidney membranes.
    Cheung AK
    Blood Purif; 1987; 5(2-3):155-61. PubMed ID: 3113447
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Changes in leukocyte counts using a cellulose acetate membrane (FB-T) during hemodialysis. A comparison with a cuprophane membrane].
    Pak K; Kobira S; Tomoyoshi T; Nishimura N
    Hinyokika Kiyo; 1986 Sep; 32(9):1231-5. PubMed ID: 3812143
    [TBL] [Abstract][Full Text] [Related]  

  • 18. No change in corrected beta 2-microglobulin concentration after cuprophane haemodialysis.
    Bergström J; Wehle B
    Lancet; 1987 Mar; 1(8533):628-9. PubMed ID: 2881162
    [No Abstract]   [Full Text] [Related]  

  • 19. [Comparison of biocompatibility of hemophane, cellulose diacetate and acrilonitile membranes in hemodialysis].
    Germin Petrović D
    Acta Med Croatica; 2004; 58(1):31-6. PubMed ID: 15125391
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Effect of hemodialysis with cuprophane and polysulfone membranes on counts of leukocytes, granulocytes, monocytes, lymphocytes and lymphocyte subsets].
    Moczulski D; Zukowska-Szczechowska E; Grzeszczak W; Religa Z; Cichoń R; Szydłowska I
    Pol Arch Med Wewn; 1994 Nov; 92(5):400-7. PubMed ID: 7885988
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.