These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
4. A double lumen suprapubic urodynamic catheter. Dewan PA Aust N Z J Surg; 1995 Sep; 65(9):672-3. PubMed ID: 7575301 [TBL] [Abstract][Full Text] [Related]
5. The three-circle single J catheter: a more stable urethral catheter for pressure flow studies. Homma Y; Imajo C; Kawabe K Int J Urol; 1995 Jul; 2(3):198-9. PubMed ID: 8536138 [TBL] [Abstract][Full Text] [Related]
7. Obstructive effect of a closed 12F urethral catheter during the emptying phase of cystometry in patients with a spinal reflex bladder. Thyberg M; Ertzgaard P; Håkansson L; Spångberg A; Granerus G Paraplegia; 1995 Jan; 33(1):40-5. PubMed ID: 7715953 [TBL] [Abstract][Full Text] [Related]
8. Long-term bladder drainage: Suprapubic catheter versus other methods: a scoping review. Hunter KF; Bharmal A; Moore KN Neurourol Urodyn; 2013 Sep; 32(7):944-51. PubMed ID: 23192860 [TBL] [Abstract][Full Text] [Related]
9. Modified J nephrostomy catheter for intravesical pressure measurement in urodynamics. Iversen P; Jensen KM; Bruskewitz RC; Madsen PO Urology; 1983 May; 21(5):550-2. PubMed ID: 6857908 [TBL] [Abstract][Full Text] [Related]
10. Applicability and reproducibility of condom catheter method for measuring isovolumetric bladder pressure. Huang Foen Chung JW; Bohnen AM; Pel JJ; Bosch JL; Niesing R; van Mastrigt R Urology; 2004 Jan; 63(1):56-60. PubMed ID: 14751348 [TBL] [Abstract][Full Text] [Related]
11. 5-microtransducer catheter in evaluation of neurogenic bladder function. Rossier AB; Fam BA Urology; 1986 Apr; 27(4):371-8. PubMed ID: 3962062 [TBL] [Abstract][Full Text] [Related]
13. New dual-channel microtip transducer catheter for urethral pressure profile and cystometry. Leach GE; Farsaii A; Raz S Urology; 1982 Nov; 20(5):555-7. PubMed ID: 6890733 [TBL] [Abstract][Full Text] [Related]
14. [Valsalva leak point pressure in the study of urinary incontinence in women]. Haab F Prog Urol; 1997 Feb; 7(1):105-7. PubMed ID: 9116725 [No Abstract] [Full Text] [Related]
15. Suprapubic versus transurethral bladder drainage after surgery for stress urinary incontinence. Bergman A; Matthews L; Ballard CA; Roy S Obstet Gynecol; 1987 Apr; 69(4):546-9. PubMed ID: 3822295 [TBL] [Abstract][Full Text] [Related]
16. The Gordian knot of urodynamics: a simple solution. Wright MP; Swami K Br J Urol; 1996 Aug; 78(2):304. PubMed ID: 8813935 [No Abstract] [Full Text] [Related]
17. Clinical experiences of direct transmural measurement of the detrusor pressure. Nyman CR; Sjöberg B Scand J Urol Nephrol; 1981; 15(3):223-7. PubMed ID: 7323742 [TBL] [Abstract][Full Text] [Related]
18. A new model for suprapubic catheterization: the MediPlus Seldinger suprapubic catheter. Mohammed A; Khan A; Shergill IS; Gujral SS Expert Rev Med Devices; 2008 Nov; 5(6):705-7. PubMed ID: 19025347 [TBL] [Abstract][Full Text] [Related]
19. The bladder during physical activity: further views on natural-filling urodynamic investigations. James ED Br J Urol; 1983 Oct; 55(5):570. PubMed ID: 6626905 [No Abstract] [Full Text] [Related]
20. Urodynamic localization of isolated bladder neck obstruction in men: studies with micturitional vesicourethral static pressure profile. Yalla SV; Waters WB; Snyder H; Varady S; Blute R J Urol; 1981 May; 125(5):677-84. PubMed ID: 7230339 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]