These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

130 related articles for article (PubMed ID: 7132327)

  • 1. In vitro determination of accuracy of cardiac output measurements by thermal dilution.
    Bilfinger TV; Lin CY; Anagnostopoulos CE
    J Surg Res; 1982 Nov; 33(5):409-14. PubMed ID: 7132327
    [TBL] [Abstract][Full Text] [Related]  

  • 2. In vitro comparison of six commercially available thermodilution cardiac output systems.
    Powner DJ; Snyder JV
    Med Instrum; 1978; 12(2):122-7. PubMed ID: 150486
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Cardiac output measurement by the thermodilution method: an in vitro test of accuracy of three commercially available automatic cardiac output computers.
    Rubini A; Del Monte D; Catena V; Attar I; Cesaro M; Soranzo D; Rattazzi G; Alati GL
    Intensive Care Med; 1995 Feb; 21(2):154-8. PubMed ID: 7775697
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Thermodilution cardiac output. Cold vs room temperature injectate and the importance of measuring the injectate temperature in the right atrium.
    Berthelsen PG; Eldrup N; Nilsson LB; Rasmussen JP
    Acta Anaesthesiol Scand; 2002 Oct; 46(9):1103-10. PubMed ID: 12366505
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Indicator amount, temperature, and intrinsic cardiac output affect thermodilution cardiac output accuracy and reproducibility.
    Renner LE; Morton MJ; Sakuma GY
    Crit Care Med; 1993 Apr; 21(4):586-97. PubMed ID: 8472580
    [TBL] [Abstract][Full Text] [Related]  

  • 6. An evaluation of thermodilution cardiac output measurement using the Swan-Ganz catheter.
    Runciman WB; Ilsley AH; Roberts JG
    Anaesth Intensive Care; 1981 Aug; 9(3):208-20. PubMed ID: 7025698
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Continuous versus bolus thermodilution cardiac output measurements--a comparative study.
    Mihaljevic T; von Segesser LK; Tönz M; Leskosek B; Seifert B; Jenni R; Turina M
    Crit Care Med; 1995 May; 23(5):944-9. PubMed ID: 7736755
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Effect of injectate temperature and thermistor position on reproducibility of thermodilution cardiac output determinations.
    Williams JE; Pfau SE; Deckelbaum LI
    Chest; 1994 Sep; 106(3):895-8. PubMed ID: 8082374
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Thermodilution cardiac output--an in vitro model of low flow states.
    Norris SL; King EG; Grace M; Weir B
    Crit Care Med; 1986 Jan; 14(1):57-9. PubMed ID: 3510106
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Comparison between cardiac output measured by the pulmonary arterial thermodilution technique and that measured by the femoral arterial thermodilution technique in a pediatric animal model.
    Rupérez M; López-Herce J; García C; Sánchez C; García E; Vigil D
    Pediatr Cardiol; 2004; 25(2):119-23. PubMed ID: 14681741
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Continuous cardiac output monitoring during adult liver transplantation: thermal filament technique versus bolus thermodilution.
    Greim CA; Roewer N; Thiel H; Laux G; Schulte am Esch J
    Anesth Analg; 1997 Sep; 85(3):483-8. PubMed ID: 9296398
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Evaluation of a new continuous thermodilution cardiac output monitor in critically ill patients: a prospective criterion standard study.
    Haller M; Zöllner C; Briegel J; Forst H
    Crit Care Med; 1995 May; 23(5):860-6. PubMed ID: 7736744
    [TBL] [Abstract][Full Text] [Related]  

  • 13. An assessment of cardiac output by thermodilution in infants and children following cardiac surgery.
    Colgan FJ; Stewart S
    Crit Care Med; 1977; 5(5):220-5. PubMed ID: 332445
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Room-temperature thermodilution cardiac output: proximal injectate lumen vs proximal infusion lumen.
    Pesola GR; Ayala B; Plante L
    Am J Crit Care; 1993 Mar; 2(2):132-3. PubMed ID: 8358461
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Multiple cardiac output measurements in man. Evaluation of a new closed-system thermodilution method.
    Stawicki JJ; Holford FD; Michelson EL; Josephson ME
    Chest; 1979 Aug; 76(2):193-7. PubMed ID: 456059
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Accuracy of thermodilution measurement of cardiac output in low flows applicable to feline and small canine patients.
    Dyson DH; McDonnell WN; Horne JA
    Can J Comp Med; 1984 Oct; 48(4):425-7. PubMed ID: 6509371
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Simple method for measurement of cardiac output by thermodilution after cardiac operation.
    McCormick JR; Dobnik DB; Mieszala JR; Berger RL
    J Thorac Cardiovasc Surg; 1979 Nov; 78(5):792-5. PubMed ID: 385998
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Thermodilution cardiac output--a systematic error.
    Runciman WB; Ilsley AH; Roberts JG
    Anaesth Intensive Care; 1981 May; 9(2):135-9. PubMed ID: 7020475
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Thermodilution cardiac output determination in hypothermic postcardiac surgery patients: room vs ice temperature injectate.
    Shellock FG; Riedinger MS; Bateman TM; Gray RJ
    Crit Care Med; 1983 Aug; 11(8):668-70. PubMed ID: 6872556
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Measurement of postoperative cardiac output by thermodilution in pediatric and adult patients.
    Moodie DS; Feldt RH; Kaye MP; Danielson GK; Pluth J; O'Fallon M
    J Thorac Cardiovasc Surg; 1979 Nov; 78(5):796-8. PubMed ID: 491734
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.