These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

125 related articles for article (PubMed ID: 7139705)

  • 1. Percutaneous vs surgical placement of intra-aortic balloon assist.
    Singh AK; Williams DO; Cooper GN; Riley RS; Karlson KE
    Cathet Cardiovasc Diagn; 1982; 8(5):519-23. PubMed ID: 7139705
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Intra-aortic balloon pumping in the elderly: percutaneous versus surgical catheter insertion.
    Di Bari M; De Alfieri W; Greppi B; Conti A; Ferrucci L; Calamandrei M; Vannucci A; Pini R; Menegatti G; Vassanelli C
    Eur Heart J; 1984 Mar; 5(3):222-6. PubMed ID: 6723691
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Percutaneous intraaortic balloon pumping: initial experience.
    Gonzalez M; Installé E; Trémouroux J
    Intensive Care Med; 1982; 8(3):143-7. PubMed ID: 7085963
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Comparison of wire-guided percutaneous insertion and conventional surgical insertion of intra-aortic balloon pumps in 151 patients.
    Alcan KE; Stertzer SH; Wallsh E; Franzone AJ; Bruno MS; DePasquale NN
    Am J Med; 1983 Jul; 75(1):24-8. PubMed ID: 6859082
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Intra-aortic counterpulsation during the surgical treatment of ischemic heart disease].
    Konstantinov BA; Shabalkin BV; Belov IuV
    Grudn Khir; 1983; (6):13-7. PubMed ID: 6654156
    [No Abstract]   [Full Text] [Related]  

  • 6. Percutaneous intraaortic balloon pumping: initial clinical experience.
    Bregman D; Casarella WJ
    Ann Thorac Surg; 1980 Feb; 29(2):153-5. PubMed ID: 7356366
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Assisted circulation by intra-aortic balloon pumping].
    Ponomareva LI; Mordashev BK
    Kardiologiia; 1982 Oct; 22(10):122-6. PubMed ID: 6757521
    [No Abstract]   [Full Text] [Related]  

  • 8. Care of the patient on the percutaneous intra-aortic counterpulsation balloon.
    Bullas JB
    Crit Care Nurse; 1982; 2(4):40-9. PubMed ID: 6925516
    [No Abstract]   [Full Text] [Related]  

  • 9. [Surgical aspects and vascular complications of intra-aortic counterpulsation].
    Shabalkin BV; Belov IuV
    Klin Khir (1962); 1982 Jul; (7):26-8. PubMed ID: 7132081
    [No Abstract]   [Full Text] [Related]  

  • 10. [Intra-aortic balloon pumping in cardiac surgery].
    Konstantinov BA; Shabalkin BV; Tarichko IuV; Nechaenko MA; Belov IuV
    Vestn Khir Im I I Grek; 1983 Jul; 131(7):22-8. PubMed ID: 6623821
    [TBL] [Abstract][Full Text] [Related]  

  • 11. What role should the intra-aortic balloon have in cardiac surgery.
    Craver JM; Kaplan JA; Jones EL; Kopchak J; Hatcher CR
    Ann Surg; 1979 Jun; 189(6):769-76. PubMed ID: 453947
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Percutaneous intra-aortic balloon pump: emphasis on complications.
    Yuen JC
    South Med J; 1991 Aug; 84(8):956-60. PubMed ID: 1882271
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Surgical versus percutaneous removal of the intra-aortic balloon.
    Cutler BS; Okike ON; Vander Salm TJ
    J Thorac Cardiovasc Surg; 1983 Dec; 86(6):907-11. PubMed ID: 6645593
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Percutaneous intraaortic balloon counterpulsation. Clinical effectiveness and hazards.
    Hauser AM; Gordon S; Gangadharan V; Ramos RG; Westveer DC; Garg AK; Timmis GC
    Chest; 1982 Oct; 82(4):422-5. PubMed ID: 7116960
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Vascular complications of intra-aortic balloon pumping.
    Alpert J; Bhaktan EK; Gielchinsky I; Gilbert L; Brener BJ; Brief DK; Parsonnet V
    Arch Surg; 1976 Nov; 111(11):1190-5. PubMed ID: 985066
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Clinical and hemodynamic effects of intraaortic balloon pumping (IABP) for high risk coronary surgery (author's transl)].
    Ida T; Yamate N; Chujo Y; Osaka S; Takei H; Shoji T
    Kyobu Geka; 1981 Nov; 34(11):839-45. PubMed ID: 7311231
    [No Abstract]   [Full Text] [Related]  

  • 17. Percutaneous intraaortic balloon insertion.
    Bregman D; Nichols AB; Weiss MB; Powers ER; Martin EC; Casarella WJ
    Am J Cardiol; 1980 Aug; 46(2):261-4. PubMed ID: 7405838
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Guidelines for effective and safe percutaneous intraaortic balloon pump insertion and removal.
    Vignola PA; Swaye PS; Gosselin AJ
    Am J Cardiol; 1981 Oct; 48(4):660-4. PubMed ID: 7282548
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Intra-aortic balloon cardiac assist: complication rates for the surgical and percutaneous insertion techniques.
    Curtis JJ; Boland M; Bliss D; Walls J; Boley T; Schmaltz R; Flaker G; Anderson SK
    Am Surg; 1988 Mar; 54(3):142-7. PubMed ID: 3348547
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Use of intra-aortic balloon pumping (IABP) in clinical cardiac surgery and management of patients with IABP.
    Watanabe H; Johnson WD; Shore RT; Kayser KL
    Jpn J Surg; 1978 Dec; 8(4):282-90. PubMed ID: 732051
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.