41. Dose distribution from a degraded 60Co gamma field. Momeni MH Health Phys; 1986 Apr; 50(4):493-507. PubMed ID: 3790202 [TBL] [Abstract][Full Text] [Related]
42. High-level gamma-ray dosimetry using common TLD phosphors. Lakshmanan AR; Bhatt RC Phys Med Biol; 1979 Nov; 24(6):1258-67. PubMed ID: 531099 [TBL] [Abstract][Full Text] [Related]
43. New parameters of annealing and re-use of TLDs based on CaSO4:Dy phosphor. Bakshi AK; Pradhan AS; Srivastava K; Kolambe DH Radiat Prot Dosimetry; 2002; 100(1-4):293-6. PubMed ID: 12382881 [TBL] [Abstract][Full Text] [Related]
44. Ultraviolet dosimetry using intrinsic thermoluminescence in CaSO4:Tm. Lakshmanan A; Bhatt RC Int J Appl Radiat Isot; 1979 Jun; 30(6):375-8. PubMed ID: 489146 [No Abstract] [Full Text] [Related]
45. Evaluation of the dosimetric response for CaSO4:Dy at low temperature. Cruz-Zaragoza E; Ramos-Bernal S; Negrón-Mendoza A; Azoŕin J Radiat Prot Dosimetry; 2002; 100(1-4):447-9. PubMed ID: 12382918 [TBL] [Abstract][Full Text] [Related]
46. CaSO4:Dy and LiF:Mg, Cu, P thermoluminescent dosimeters for environmental monitoring in ambient areas of a nuclear power plant. Zeng XS; Zeng JX; Tan GX; Mai WJ Health Phys; 1996 Mar; 70(3):367-71. PubMed ID: 8609029 [TBL] [Abstract][Full Text] [Related]
47. Development of a technique for improving coefficient of variation of CaSO4:Dy teflon-based TLD personnel monitoring system in low-dose region. Pradhan SM; Sneha C; Sahai MK; Chougaonkar MP; Babu DA Radiat Prot Dosimetry; 2015 Dec; 167(4):429-36. PubMed ID: 25527179 [TBL] [Abstract][Full Text] [Related]
48. Study on the response of indigenously developed CaSO4:Dy phosphor-based neutron dosemeter. Bakshi AK; Pradhan AS; Kher RK; Srivastava K; Varadharajan G; Chatterjee S; Sathian V Radiat Prot Dosimetry; 2009 Jan; 133(2):73-80. PubMed ID: 19264830 [TBL] [Abstract][Full Text] [Related]
49. High-exposure ultraviolet response and sensitisation of CaSO4:Dy. Shastry SS; Shinde SS Phys Med Biol; 1979 Sep; 24(5):1033-6. PubMed ID: 515175 [No Abstract] [Full Text] [Related]
50. On the relationship between dose-, energy- and LET-response of thermoluminescent detectors. Olko P; Bilski P; El-Faramawy NA; Göksu HY; Kim JL; Kopec R; Waligórski MP Radiat Prot Dosimetry; 2006; 119(1-4):15-22. PubMed ID: 16644968 [TBL] [Abstract][Full Text] [Related]
51. New sintered thermoluminescent dosimeters for personnel and environmental dosimetry. Prokic MS Health Phys; 1982 Jun; 42(6):849-55. PubMed ID: 7107292 [TBL] [Abstract][Full Text] [Related]
52. Build-up effects at air cavities measured with thin thermoluminescent dosimeters. Nilsson B; Schnell PO Acta Radiol Ther Phys Biol; 1976 Oct; 15(5):427-32. PubMed ID: 1007944 [TBL] [Abstract][Full Text] [Related]
53. A preliminary evaluation of CaSO4:Dy thermoluminescent dosimeters. McDougall RS; Axt JC Health Phys; 1973 Dec; 25(6):612-3. PubMed ID: 4784271 [No Abstract] [Full Text] [Related]
54. In vivo absorbed dose measurements with mini-TLDs--parameters affecting the reliability. Strandh M; Strand SE Acta Oncol; 1996; 35(6):713-9. PubMed ID: 8938219 [TBL] [Abstract][Full Text] [Related]
59. The application of CaSO4:Dy (TLD-900) to diagnostic x-ray exposures. Niroomand-Rad A; DeWerd LA Med Phys; 1983; 10(5):691-4. PubMed ID: 6646078 [TBL] [Abstract][Full Text] [Related]
60. Coloured glasses for high dose dosimetry using the thermoluminescent technique. Caldas LV; Teixeira MI Radiat Prot Dosimetry; 2004; 111(1):13-5. PubMed ID: 15367761 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]