These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

102 related articles for article (PubMed ID: 7142710)

  • 1. A novel method for the rapid bleeding of rats from the tail vein.
    Shek PN; Howe SA
    J Immunol Methods; 1982 Sep; 53(2):255-60. PubMed ID: 7142710
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A Contemporary Warming/Restraining Device for Efficient Tail Vein Injections in a Murine Fungal Sepsis Model.
    Yano J; Lilly EA; Noverr MC; Fidel PL
    J Vis Exp; 2020 Nov; (165):. PubMed ID: 33226026
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A method for rapid and frequent blood collection from the rat tail vein.
    Frank P; Schoenhard GL; Burton E
    J Pharmacol Methods; 1991 Nov; 26(3):233-8. PubMed ID: 1753747
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Simple method for bleeding the unanaesthetized rat by tail venipuncture.
    Omaye ST; Skala JH; Gretz MD; Schaus EE; Wade CE
    Lab Anim; 1987 Jul; 21(3):261-4. PubMed ID: 3626473
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Blood sampling from the retro-orbital plexus, the saphenous vein and the tail vein in rats: comparative effects on selected behavioural and blood variables.
    Van Herck H; Baumans V; Brandt CJ; Boere HA; Hesp AP; van Lith HA; Schurink M; Beynen AC
    Lab Anim; 2001 Apr; 35(2):131-9. PubMed ID: 11315161
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Sequential blood samples from the tail vein of rats and mice obtained with modified Liebig condenser jackets and vacuum.
    Nerenberg ST; Zedler P
    J Lab Clin Med; 1975 Mar; 85(3):523-6. PubMed ID: 1117211
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Evaluation of warming devices for lateral tail vein blood collection in mice (Mus musculus).
    David JM; Chen X
    J Pharmacol Toxicol Methods; 2018; 94(Pt 1):87-93. PubMed ID: 29906510
    [No Abstract]   [Full Text] [Related]  

  • 8. Utility of capillary microsampling for rat pharmacokinetic studies: Comparison of tail-vein bleed to jugular vein cannula sampling.
    Korfmacher W; Luo Y; Ho S; Sun W; Shen L; Wang J; Wu Z; Guo Y; Snow G; O'Shea T
    J Pharmacol Toxicol Methods; 2015; 76():7-14. PubMed ID: 26164093
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Repeated Blood Collection from Tail Vein of Non-Anesthetized Rats with a Vacuum Blood Collection System.
    Zou W; Yang Y; Gu Y; Zhu P; Zhang M; Cheng Z; Liu X; Yu Y; Peng X
    J Vis Exp; 2017 Dec; (130):. PubMed ID: 29286462
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A rapid method for repeated collection of blood from the tail vein of rats.
    Stearns SM; Lee PW
    Lab Anim Sci; 1984 Aug; 34(4):395-6. PubMed ID: 6482382
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Heat vasodilatation of the rat tail.
    Hellström B
    Can J Physiol Pharmacol; 1975 Apr; 53(2):202-6. PubMed ID: 1137816
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Transjugular hepatic vein cannulation in rats with nonisotopic in vivo verification.
    Iguchi A; Burleson PD; Szabo AJ
    Am J Physiol; 1979 Dec; 237(6):H730-3. PubMed ID: 517673
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A simple low-cost restrainer for the intravenous injection of mice.
    Catty D; Lehmann PF
    Sabouraudia; 1978 Jun; 16(2):89-90. PubMed ID: 694717
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Pharmacokinetic comparisons of tail-bleeding with cannula- or retro-orbital bleeding techniques in rats using six marketed drugs.
    Hui YH; Huang NH; Ebbert L; Bina H; Chiang A; Maples C; Pritt M; Kern T; Patel N
    J Pharmacol Toxicol Methods; 2007; 56(2):256-64. PubMed ID: 17618130
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A simple technique for repeated blood collection from the tail vein of the rat.
    Furuhama K; Onodera T
    J Toxicol Sci; 1983 May; 8(2):161-3. PubMed ID: 6620428
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Impact assessment of tail-vein injection in mice using a modified anaesthesia induction chamber versus a common restrainer without anaesthesia.
    Resch M; Neels T; Tichy A; Palme R; Rülicke T
    Lab Anim; 2019 Apr; 53(2):190-201. PubMed ID: 30089439
    [TBL] [Abstract][Full Text] [Related]  

  • 17. The tail veins of the Philippine carabao (Bubalus bubalis) and a safer method for venipuncture.
    Maala CP
    Anat Histol Embryol; 1981 Jun; 10(2):180-6. PubMed ID: 6455936
    [No Abstract]   [Full Text] [Related]  

  • 18. A refined method for sequential blood sampling by tail incision in rats.
    Fluttert M; Dalm S; Oitzl MS
    Lab Anim; 2000 Oct; 34(4):372-8. PubMed ID: 11072857
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Comparison between tail vein and jugular vein cannulation in cattle.
    Sears PM; Paape MJ; Pearson RE; Gwazdauskas FC
    J Dairy Sci; 1978 Jul; 61(7):974-9. PubMed ID: 701538
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Restraint device for serial blood sampling of ferrets.
    Curl JL; Curl JS
    Lab Anim Sci; 1985 Jun; 35(3):296-7. PubMed ID: 4021441
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.