These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

90 related articles for article (PubMed ID: 7153161)

  • 1. Nonlinear fluid systems identified by random noise input.
    Delavault E; Saumon G; Georges R
    J Appl Physiol Respir Environ Exerc Physiol; 1982 Dec; 53(6):1643-9. PubMed ID: 7153161
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Time series versus Fourier transform methods for estimation of respiratory impedance spectra.
    Davis KA; Lutchen KR
    Int J Biomed Comput; 1991; 27(3-4):261-76. PubMed ID: 2050434
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Measurement of total respiratory impedance via the endotracheal tube; a model study.
    Michels A; Làndsér FJ; Cauberghs M; Van de Woestijne KP
    Bull Eur Physiopathol Respir; 1986; 22(6):615-20. PubMed ID: 3828553
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Recording pressure at the distal end of the endotracheal tube to measure respiratory impedance.
    Navajas D; Farré R; Rotger M; Canet J
    Eur Respir J; 1989 Feb; 2(2):178-84. PubMed ID: 2522896
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Measurement of respiratory impedance by impulse oscillometry--effects of endotracheal tubes.
    Kuhnle GE; Brandt T; Roth U; Goetz AE; Smith HJ; Peter K
    Res Exp Med (Berl); 2000 Dec; 200(1):17-26. PubMed ID: 11197918
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Respiratory system impedance from 4 to 40 Hz in paralyzed intubated infants with respiratory disease.
    Dorkin HL; Stark AR; Werthammer JW; Strieder DJ; Fredberg JJ; Frantz ID
    J Clin Invest; 1983 Sep; 72(3):903-10. PubMed ID: 6886009
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Respiratory resistance by end-inspiratory occlusion and forced oscillations in intubated patients.
    Beydon L; Malassiné P; Lorino AM; Mariette C; Bonnet F; Harf A; Lorino H
    J Appl Physiol (1985); 1996 Apr; 80(4):1105-11. PubMed ID: 8926233
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A new correction technique for measuring respiratory impedance through an endotracheal tube.
    Lorino AM; Beydon L; Mariette C; Dahan E; Lorino H
    Eur Respir J; 1996 May; 9(5):1079-86. PubMed ID: 8793472
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Double lumen endotracheal tube for percutaneous tracheostomy.
    Vargas M; Servillo G; Tessitore G; Aloj F; Brunetti I; Arditi E; Salami D; Kacmarek RM; Pelosi P
    Respir Care; 2014 Nov; 59(11):1652-9. PubMed ID: 25161301
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Gas flow between coaxial tubes: impedance to gas flow in an endotracheal tube increases with a catheter within.
    Magee PT
    Proc Inst Mech Eng H; 2012 Jun; 226(6):491-4. PubMed ID: 22783765
    [TBL] [Abstract][Full Text] [Related]  

  • 11. In vitro versus in vivo comparison of endotracheal tube airflow resistance.
    Wright PE; Marini JJ; Bernard GR
    Am Rev Respir Dis; 1989 Jul; 140(1):10-6. PubMed ID: 2751156
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Characterization and validation of forced input method for respiratory impedance measurement.
    Delavault E; Saumon G; Georges R
    Respir Physiol; 1980 Apr; 40(1):119-36. PubMed ID: 6446750
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Neonatal endotracheal flowmeter for tidal volume, airway pressure, and end-tidal gas.
    Brady JP; Deming DD; McCann EM
    J Appl Physiol (1985); 1985 Mar; 58(3):1023-5. PubMed ID: 3156842
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Pulmonary impedance in dogs measured by forced random noise with a retrograde catheter.
    Fullton JM; Hayes DA; Pimmel RL
    J Appl Physiol Respir Environ Exerc Physiol; 1982 Mar; 52(3):725-33. PubMed ID: 7068488
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Interaction of oscillatory and steady turbulent flows in airway tubes during impedance measurement.
    Louis B; Isabey D
    J Appl Physiol (1985); 1993 Jan; 74(1):116-25. PubMed ID: 8444681
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Respiratory mechanics studied by forced oscillations during artificial ventilation.
    Peslin R; Felicio da Silva J; Duvivier C; Chabot F
    Eur Respir J; 1993 Jun; 6(6):772-84. PubMed ID: 8339794
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Calculation of intratracheal airway pressure in ventilated neonatal piglets with endotracheal tube leaks.
    Nikischin W; Herber-Jonat S; von Bismarck P; Lange M; Grabitz R
    Crit Care Med; 2007 May; 35(5):1383-9. PubMed ID: 17414085
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Respiratory impedance spectral estimation for digitally created random noise.
    Davis KA; Lutchen KR
    Ann Biomed Eng; 1991; 19(2):179-95. PubMed ID: 2048776
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Influence of site of tracheal pressure measurement on in situ estimation of endotracheal tube resistance.
    Navalesi P; Hernandez P; Laporta D; Landry JS; Maltais F; Navajas D; Gottfried SB
    J Appl Physiol (1985); 1994 Dec; 77(6):2899-906. PubMed ID: 7896638
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Mechanical properties of the respiratory system derived from morphologic insight.
    Ionescu CM; Segers P; De Keyser R
    IEEE Trans Biomed Eng; 2009 Apr; 56(4):949-59. PubMed ID: 19423424
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.