196 related articles for article (PubMed ID: 7164260)
1. Development and clinical application of a new membrane oxygenator using a microporous polysulfone membrane.
Dohi T; Hamada E; Murakami T; Nawa S; Komoto Y; Teramoto S; Kanbayashi T
Trans Am Soc Artif Intern Organs; 1982; 28():338-41. PubMed ID: 7164260
[TBL] [Abstract][Full Text] [Related]
2. DIDECMO: a new polymethylpentene oxygenator for pediatric extracorporeal membrane oxygenation.
Agati S; Ciccarello G; Fachile N; Scappatura RM; Grasso D; Salvo D; Undar A; Mignosa C
ASAIO J; 2006; 52(5):509-12. PubMed ID: 16966847
[TBL] [Abstract][Full Text] [Related]
3. [Present status and future observation of membrane oxygenator].
Teramoto S
Kyobu Geka; 1989 Jul; 42(8 Suppl):665-9. PubMed ID: 2691748
[TBL] [Abstract][Full Text] [Related]
4. Development of the oxygenator: past, present, and future.
Iwahashi H; Yuri K; Nosé Y
J Artif Organs; 2004; 7(3):111-20. PubMed ID: 15558331
[TBL] [Abstract][Full Text] [Related]
5. Development of a new silicone membrane oxygenator for ECMO.
Nakata K; Maeda T; Murabayashi S; Yoshikawa M; Takano T; Iwasaki A; Nonaka K; Linneweber J; Kawahito S; Glueck J; Sato K; Kuwana J; Nosé Y
Ann Thorac Cardiovasc Surg; 2000 Dec; 6(6):373-7. PubMed ID: 11173351
[TBL] [Abstract][Full Text] [Related]
6. From the spinning disc to the membrane oxygenator for open-heart surgery.
Björk VO; Sternlieb JJ; Davenport C
Scand J Thorac Cardiovasc Surg; 1985; 19(3):207-16. PubMed ID: 3936170
[TBL] [Abstract][Full Text] [Related]
7. Use of a membrane oxygenator for open-heart surgery in infants.
Murphy DA; Gillis DA; Lau H
Can J Surg; 1976 Mar; 19(2):103-7. PubMed ID: 1260550
[TBL] [Abstract][Full Text] [Related]
8. [Use of a membrane oxygenator in extracorporeal circulation in the child. Preliminary conclusions].
Aubert J; Frigiola A; Pannetier A; Couvélly JP
Ann Anesthesiol Fr; 1977; 18(1):22-8. PubMed ID: 16540
[TBL] [Abstract][Full Text] [Related]
9. A new hollow fiber membrane oxygenator with an integral heat exchanger: a hematological evaluation in dogs.
Ennema JJ; Mook PH; Elstrodt JM; Wildevuur CR
Thorac Cardiovasc Surg; 1983 Dec; 31(6):359-64. PubMed ID: 6198757
[TBL] [Abstract][Full Text] [Related]
10. Development of an intravenous membrane oxygenator: a new concept in mechanical support for the failing lung.
Hattler BG; Reeder GD; Sawzik PJ; Walters FR; Pham SM; Kormos RL; Keenan RJ; Griffith BP; Armitage JM; Hardesty RL
J Heart Lung Transplant; 1994; 13(6):1003-8. PubMed ID: 7865505
[TBL] [Abstract][Full Text] [Related]
11. Preclinical evaluation of a new hollow fiber silicone membrane oxygenator for pediatric cardiopulmonary bypass: ex-vivo study.
Kawahito S; Haraguchi S; Maeda T; Motomura T; Takano T; Nonaka K; Linneweber J; Ichikawa S; Kawamura M; Ishitoya H; Glueck J; Sato K; Nosé Y
Ann Thorac Cardiovasc Surg; 2002 Feb; 8(1):7-11. PubMed ID: 11916436
[TBL] [Abstract][Full Text] [Related]
12. [Clinical experiences with a new membrane oxygenator with low priming volume (D702 MASTER FLO 51), studies during pulsatile and constant flow perfusion].
Kobayashi S; Kitamura S; Kawachi K; Nishii T; Taniguchi S; Fukutomi M; Mizuguchi K; Hamada Y; Hasegawa J
Kyobu Geka; 1989 Jun; 42(6):453-6. PubMed ID: 2779048
[TBL] [Abstract][Full Text] [Related]
13. [Clinical experience with a membrane oxygenator, COBE VPCML, for pediatric open heart surgery--comparison with the bubble oxygenator].
Nagatsu M; Sawatari K; Imai Y; Takanashi Y; Kurosawa H; Nakae S; Hoshino S; Soejima K; Sugiyama Y; Yoshikai M
Kyobu Geka; 1987 Feb; 40(2):118-22. PubMed ID: 3560568
[No Abstract] [Full Text] [Related]
14. Development of an implantable oxygenator with cross-flow pump.
Asakawa Y; Funakubo A; Fukunaga K; Taga I; Higami T; Kawamura T; Fukui Y
ASAIO J; 2006; 52(3):291-5. PubMed ID: 16760718
[TBL] [Abstract][Full Text] [Related]
15. Validation of a rat model of cardiopulmonary bypass with a new miniaturized hollow fiber oxygenator.
Cresce GD; Walpoth BH; Mugnai D; Innocente F; Rungatscher A; Luciani GB; Zaniboni A; Battistuzzi G; Tessari M; Kalangos A; Mazzucco A; Faggian G
ASAIO J; 2008; 54(5):514-8. PubMed ID: 18812744
[TBL] [Abstract][Full Text] [Related]
16. [Clinical application of hollow-fiber membrane oxygenator for open heart surgery in infants and children].
Utsonomiya H; Shimada M; Tsunemoto M; Ota N; Mashiko K; Kanazawa H; Ii Y; Kanno M; Takahashi A
Kyobu Geka; 1984 Mar; 37(3):211-3. PubMed ID: 6425547
[No Abstract] [Full Text] [Related]
17. Experimental use of a compact centrifugal pump and membrane oxygenator as a cardiopulmonary support system.
Suenaga E; Naito K; Cao ZL; Suda H; Ueno T; Natsuaki M; Itoh T
Artif Organs; 2000 Nov; 24(11):912-5. PubMed ID: 11119082
[TBL] [Abstract][Full Text] [Related]
18. Fabrication, Characterization, and Hemocompatibility Investigation of Polysulfone Grafted With Polyethylene Glycol and Heparin Used in Membrane Oxygenators.
Zheng Z; Wang W; Huang X; Lv Q; Fan W; Yu W; Li L; Zhang Z
Artif Organs; 2016 Nov; 40(11):E219-E229. PubMed ID: 28374499
[TBL] [Abstract][Full Text] [Related]
19. Feasibility of a new hollow fiber silicone membrane oxygenator for long-term ECMO application.
Kawahito S; Maeda T; Motomura T; Takano T; Nonaka K; Linneweber J; Ichikawa S; Ishitoya H; Hanazaki K; Glueck J; Sato K; Nosé Y
J Med Invest; 2002 Aug; 49(3-4):156-62. PubMed ID: 12323005
[TBL] [Abstract][Full Text] [Related]
20. Right atrial bypass model in the dog.
Breen PH; Isserles SA
Am J Vet Res; 1995 Feb; 56(2):208-14. PubMed ID: 7717588
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]