These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

117 related articles for article (PubMed ID: 7178864)

  • 1. A technique for measurements of plantar flexion torque with the Cybex II dynamometer.
    Nistor L; Markhede G; Grimby G
    Scand J Rehabil Med; 1982; 14(4):163-6. PubMed ID: 7178864
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Measurement of strength of hip joint muscles.
    Markhede G; Grimby G
    Scand J Rehabil Med; 1980; 12(4):169-74. PubMed ID: 7268325
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Reproducibility of an isokinetic strength-testing protocol of the knee and ankle in older adults.
    Hartmann A; Knols R; Murer K; de Bruin ED
    Gerontology; 2009; 55(3):259-68. PubMed ID: 18997454
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Isokinetic, isometric and isotonic strength relationships.
    Knapik JJ; Wright JE; Mawdsley RH; Braun JM
    Arch Phys Med Rehabil; 1983 Feb; 64(2):77-80. PubMed ID: 6824423
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Testing of isokinetic muscle strength in the ankle.
    Oberg B; Bergman T; Tropp H
    Med Sci Sports Exerc; 1987 Jun; 19(3):318-22. PubMed ID: 3600247
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Reliability of measuring isometric and isokinetic peak torque, rate of torque development, integrated electromyography, and tibial nerve conduction velocity.
    Sleivert GG; Wenger HA
    Arch Phys Med Rehabil; 1994 Dec; 75(12):1315-21. PubMed ID: 7993170
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Reliability of knee extension and flexion measurements using the Con-Trex isokinetic dynamometer.
    Maffiuletti NA; Bizzini M; Desbrosses K; Babault N; Munzinger U
    Clin Physiol Funct Imaging; 2007 Nov; 27(6):346-53. PubMed ID: 17944656
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The development, validity, and reliability of a manual muscle testing device with integrated limb position sensors.
    Li RC; Jasiewicz JM; Middleton J; Condie P; Barriskill A; Hebnes H; Purcell B
    Arch Phys Med Rehabil; 2006 Mar; 87(3):411-7. PubMed ID: 16500178
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Reliability of isokinetic ankle dorsiflexor strength measurements in healthy young men and women.
    Holmbäck AM; Porter MM; Downham D; Lexell J
    Scand J Rehabil Med; 1999 Dec; 31(4):229-39. PubMed ID: 10599900
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Strength testing with a portable dynamometer: reliability for upper and lower extremities.
    Agre JC; Magness JL; Hull SZ; Wright KC; Baxter TL; Patterson R; Stradel L
    Arch Phys Med Rehabil; 1987 Jul; 68(7):454-8. PubMed ID: 3606371
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Reliability of isokinetic strength imbalance ratios measured using the Cybex NORM dynamometer.
    Impellizzeri FM; Bizzini M; Rampinini E; Cereda F; Maffiuletti NA
    Clin Physiol Funct Imaging; 2008 Mar; 28(2):113-9. PubMed ID: 18070123
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Test-retest reliability of isokinetic knee extension and flexion.
    Sole G; Hamrén J; Milosavljevic S; Nicholson H; Sullivan SJ
    Arch Phys Med Rehabil; 2007 May; 88(5):626-31. PubMed ID: 17466732
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Reliability of a new instrument for measuring plantarflexor muscle strength.
    Ortqvist M; Gutierrez-Farewik EM; Farewik M; Jansson A; Bartonek A; Broström E
    Arch Phys Med Rehabil; 2007 Sep; 88(9):1164-70. PubMed ID: 17826463
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Isometric and isokinetic hip abductor strength in persons with above-knee amputations.
    Ryser DK; Erickson RP; Cahalan T
    Arch Phys Med Rehabil; 1988 Oct; 69(10):840-5. PubMed ID: 3178451
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Effect of contraction form and contraction velocity on the differences between resultant and measured ankle joint moments.
    Arampatzis A; De Monte G; Morey-Klapsing G
    J Biomech; 2007; 40(7):1622-8. PubMed ID: 16928376
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Isokinetic and isometric torque relationships in the human body.
    Knapik JJ; Ramos MU
    Arch Phys Med Rehabil; 1980 Feb; 61(2):64-7. PubMed ID: 7369840
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Torque curves produced at the knee during isometric and isokinetic exercise.
    Scudder GN
    Arch Phys Med Rehabil; 1980 Feb; 61(2):68-73. PubMed ID: 7369841
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Effect of ankle position fixation on peak torque and electromyographic activity of the knee flexors and extensors.
    Croce RV; Miller JP; St Pierre P
    Electromyogr Clin Neurophysiol; 2000 Sep; 40(6):365-73. PubMed ID: 11039121
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Measurement of the isometric dorsiflexion and plantar flexion force in the ankle joint].
    Göpfert B; Valderrabano V; Hintermann B; Wirz D
    Biomed Tech (Berl); 2005 Sep; 50(9):282-6. PubMed ID: 16185037
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Enhanced precision of ankle torque measure with an open-unit dynamometer mounted with a 3D force-torque sensor.
    Toumi A; Leteneur S; Gillet C; Debril JF; Decoufour N; Barbier F; Jakobi JM; Simoneau-Buessinger E
    Eur J Appl Physiol; 2015 Nov; 115(11):2303-10. PubMed ID: 26143547
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.