These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

107 related articles for article (PubMed ID: 7182964)

  • 41. [Characteristics of the clinical manifestations of glaucoma with a relatively low ocular tonus and various levels of arterial pressure].
    Iusupov AIu; Saliev MS; Zakirova ZI; Vasilenko AV
    Vestn Oftalmol; 1988; 104(5):6-8. PubMed ID: 3222838
    [No Abstract]   [Full Text] [Related]  

  • 42. A clinical comparison of dynamic contour tonometry versus Goldmann applanation tonometry.
    Yalcinbayir O; Baykara M; Atasoy A; Ozcetin H
    Ophthalmic Surg Lasers Imaging; 2010; 41(4):437-42. PubMed ID: 20438047
    [TBL] [Abstract][Full Text] [Related]  

  • 43. Comparison of intraocular pressure measurement between rebound, non-contact and Goldmann applanation tonometry in treated glaucoma patients.
    Vincent SJ; Vincent RA; Shields D; Lee GA
    Clin Exp Ophthalmol; 2012; 40(4):e163-70. PubMed ID: 21883774
    [TBL] [Abstract][Full Text] [Related]  

  • 44. Influence of age, central corneal thickness, and quality score on dynamic contour tonometry.
    Jordão ML; Lupinacci AP; Ferreira EL; Enomoto IJ; Costa VP
    Eye (Lond); 2009 Jun; 23(6):1364-9. PubMed ID: 18791544
    [TBL] [Abstract][Full Text] [Related]  

  • 45. The proview phosphene tonometer: a clinical evaluation.
    Leung DY; Lam DS
    Eye (Lond); 2005 Nov; 19(11):1227; author reply 1227-8. PubMed ID: 15543186
    [No Abstract]   [Full Text] [Related]  

  • 46. [Once more about the diagnostic capacities of elastic tonometry].
    Avetisov SE; Bubnova IA; Antonov AA
    Vestn Oftalmol; 2008; 124(5):19-21. PubMed ID: 19062552
    [TBL] [Abstract][Full Text] [Related]  

  • 47. [Results of the bulbar compression test (BCT) and its significance in the prognosis of glaucoma].
    Doege E; Eichler C
    Cesk Oftalmol; 1980 Sep; 36(5):311-6. PubMed ID: 7418039
    [No Abstract]   [Full Text] [Related]  

  • 48. Average distribution of intraocular pressure in Indians by applanation tonometer.
    Gupta SP; Mehta P
    Indian J Ophthalmol; 1971 Jun; 19(2):85-90. PubMed ID: 15744977
    [No Abstract]   [Full Text] [Related]  

  • 49. [Effects of central corneal thickness and corneal curvature on measurement of intraocular pressure with Goldmann applanation tonometer and non-contact tonometer].
    Zhang Y; Zhao JL; Bian AL; Liu XL; Jin YM
    Zhonghua Yan Ke Za Zhi; 2009 Aug; 45(8):713-8. PubMed ID: 20021884
    [TBL] [Abstract][Full Text] [Related]  

  • 50. [Glaucoma, tonometry and anaesthesia (author's transl)].
    Heilmann K
    Anaesthesist; 1975 Mar; 24(3):97-102. PubMed ID: 1096667
    [TBL] [Abstract][Full Text] [Related]  

  • 51. [The diagnostic and prognostic significance of increase intra-ocular pressure (author's transl)].
    Leydhecker W
    Klin Monbl Augenheilkd; 1977 May; 170(5):679-84. PubMed ID: 894967
    [TBL] [Abstract][Full Text] [Related]  

  • 52. [Comparative characteristics of current tonometric methods].
    Astakhov IuS; Akopov EL; Potemkin VV
    Vestn Oftalmol; 2008; 124(5):11-4. PubMed ID: 19062549
    [TBL] [Abstract][Full Text] [Related]  

  • 53. [A new screening method for determining tolerant intraocular pressure].
    Avetisov SE; Mamikonian VR; Kazarian EE; Shmeleva-Demir OA; Mazurova IuV; Ryzhkova EG; Galoian NS; Tatevosian AA
    Vestn Oftalmol; 2009; 125(5):3-7. PubMed ID: 19916324
    [TBL] [Abstract][Full Text] [Related]  

  • 54. [Intraocular pressure measurements with the Proview self-tonometer in comparison of Goldmann applanation tonometry in healthy and glaucomatous eyes].
    Meyer MW; Yevelenko V; Hoy L; Meyer A; Erb C
    Klin Monbl Augenheilkd; 2006 Nov; 223(11):899-903. PubMed ID: 17131250
    [TBL] [Abstract][Full Text] [Related]  

  • 55. [Tonometry with a new non-contact tonometer].
    Langmann G; Schuhmann G; Langmann A; Zenz H
    Klin Monbl Augenheilkd; 1990 Nov; 197(5):393-6. PubMed ID: 2290296
    [TBL] [Abstract][Full Text] [Related]  

  • 56. [A comparative study of various methods of measuring intraocular pressure].
    Růzicková E; Pitrová S; Cihlárová J; Síp L
    Cesk Oftalmol; 1989 Nov; 45(6):416-9. PubMed ID: 2605657
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Dynamic contour tonometry for intraocular pressure measurement.
    Kamppeter BA; Jonas JB
    Am J Ophthalmol; 2005 Aug; 140(2):318-20. PubMed ID: 16086958
    [TBL] [Abstract][Full Text] [Related]  

  • 58. Reliability of the Nidek NT-1000 non contact tonometer.
    Van de Velde T; Zeyen T
    Bull Soc Belge Ophtalmol; 1995; 255():19-22. PubMed ID: 7496571
    [TBL] [Abstract][Full Text] [Related]  

  • 59. Ocular hypertension. Follow-up of 109 cases from 1963 to 1974.
    Walker WM
    Trans Ophthalmol Soc U K (1962); 1974 Jul; 94(2):525-34. PubMed ID: 4534189
    [No Abstract]   [Full Text] [Related]  

  • 60. Applanation tonometry without fluorescein.
    Rumelt MB
    Am J Ophthalmol; 1980 Feb; 89(2):309. PubMed ID: 7355984
    [No Abstract]   [Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.