These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

191 related articles for article (PubMed ID: 7184704)

  • 1. Pattern ergs and check size: absence of spatial frequency tuning.
    Kirkham TH; Coupland SG
    Curr Eye Res; 1982-1983; 2(8):511-21. PubMed ID: 7184704
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Retinocortical time exhibits spatial selectivity.
    Rimmer S; Iragui V; Klauber MR; Katz B
    Invest Ophthalmol Vis Sci; 1989 Sep; 30(9):2045-9. PubMed ID: 2777522
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The pattern electroretinogram in glaucoma patients with confirmed visual field deficits.
    Hood DC; Xu L; Thienprasiddhi P; Greenstein VC; Odel JG; Grippo TM; Liebmann JM; Ritch R
    Invest Ophthalmol Vis Sci; 2005 Jul; 46(7):2411-8. PubMed ID: 15980229
    [TBL] [Abstract][Full Text] [Related]  

  • 4. The pattern electroretinogram in anterior visual pathway dysfunction and its relationship to the pattern visual evoked potential: a personal clinical review of 743 eyes.
    Holder GE
    Eye (Lond); 1997; 11 ( Pt 6)():924-34. PubMed ID: 9537157
    [TBL] [Abstract][Full Text] [Related]  

  • 5. The pattern electroretinogram: technical aspects and clinical significance.
    Rimmer S; Katz B
    J Clin Neurophysiol; 1989 Jan; 6(1):85-99. PubMed ID: 2644303
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Pattern electroretinography and visual evoked potentials in optic nerve diseases.
    Atilla H; Tekeli O; Ornek K; Batioglu F; Elhan AH; Eryilmaz T
    J Clin Neurosci; 2006 Jan; 13(1):55-9. PubMed ID: 16410198
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Interocular amplitude and latency differences of pattern ERG and pattern VEP parameters.
    Fejes I; Kocsis PB; Benedek G; Janáky M
    Optom Vis Sci; 2014 Apr; 91(4):472-6. PubMed ID: 24492757
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The pattern electroretinogram.
    Berninger TA; Arden GB
    Eye (Lond); 1988; 2 Suppl():S257-83. PubMed ID: 3076152
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Simultaneous pattern-reversal electroretinograms and visual evoked potentials in diseases of the macula and optic nerve.
    Sherman J
    Ann N Y Acad Sci; 1982; 388():214-26. PubMed ID: 6953869
    [TBL] [Abstract][Full Text] [Related]  

  • 10. The value of two-field pattern electroretinogram in routine clinical electrophysiologic practice.
    Lenassi E; Robson AG; Hawlina M; Holder GE
    Retina; 2012 Mar; 32(3):588-99. PubMed ID: 21878848
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Electrophysiological assessment of optic nerve disease.
    Holder GE
    Eye (Lond); 2004 Nov; 18(11):1133-43. PubMed ID: 15534599
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Combined use of pattern electroretinography and pattern visual evoked potentials in neuroophthalmological practice].
    Benedek K; Pálffy A; Bencsik K; Fejes I; Rajda C; Tuboly G; Liszli P
    Ideggyogy Sz; 2008 Jan; 61(1-2):33-41. PubMed ID: 18372773
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Clinical ability of pattern electroretinograms and visual evoked potentials in detecting visual dysfunction in ocular hypertension and glaucoma.
    Parisi V; Miglior S; Manni G; Centofanti M; Bucci MG
    Ophthalmology; 2006 Feb; 113(2):216-28. PubMed ID: 16406535
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Atrophy of the ganglion cells reduces pattern ERG not only in fine but also in coarse test patterns].
    Gerling J; Geiger K; Bach M
    Fortschr Ophthalmol; 1991; 88(6):833-7. PubMed ID: 1794815
    [TBL] [Abstract][Full Text] [Related]  

  • 15. The importance of the electrophysiological tests in the early diagnosis of ganglion cells and/or optic nerve dysfunction coexisting with pituitary adenoma: an overview.
    Lachowicz E; Lubiński W
    Doc Ophthalmol; 2018 Dec; 137(3):193-202. PubMed ID: 30374652
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Clinical application of simultaneous pattern VEP and pattern ERG recording.
    Song HS; Ku WC; Yeh SF
    Changgeng Yi Xue Za Zhi; 1995 Jun; 18(2):133-9. PubMed ID: 7641105
    [TBL] [Abstract][Full Text] [Related]  

  • 17. The pattern electroretinogram in optic nerve disease.
    Seiple W; Price MJ; Kupersmith M; Siegel IM; Carr RE
    Ophthalmology; 1983 Sep; 90(9):1127-32. PubMed ID: 6646652
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Correlation of pattern electroretinogram with optic disc cup shape in ocular hypertension.
    Salgarello T; Colotto A; Falsini B; Buzzonetti L; Cesari L; Iarossi G; Scullica L
    Invest Ophthalmol Vis Sci; 1999 Aug; 40(9):1989-97. PubMed ID: 10440253
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Development of pattern ERG and pattern VEP spatial resolution in kittens with unilateral esotropia.
    Yin ZQ; Li CY; Pei X; Vaegan ; Fang QX
    Invest Ophthalmol Vis Sci; 1994 Feb; 35(2):626-34. PubMed ID: 8113013
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Relationship between electrophysiological, psychophysical, and anatomical measurements in glaucoma.
    Garway-Heath DF; Holder GE; Fitzke FW; Hitchings RA
    Invest Ophthalmol Vis Sci; 2002 Jul; 43(7):2213-20. PubMed ID: 12091419
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.