40 related articles for article (PubMed ID: 7187286)
1. [Effects of beam weakening and beam hardening on the measured CT values].
Schultz E; Lackner K
Computertomographie; 1981 Jun; 1(2):83-8. PubMed ID: 7187286
[TBL] [Abstract][Full Text] [Related]
2. [The effect of beam hardening on CT values].
Weidenmaier W; Christ G
Rofo; 1985 Dec; 143(6):697-701. PubMed ID: 3001864
[TBL] [Abstract][Full Text] [Related]
3. Computed Tomography Number Measurement Consistency Under Different Beam Hardening Conditions: Comparison Between Dual-Energy Spectral Computed Tomography and Conventional Computed Tomography Imaging in Phantom Experiment.
He T; Qian X; Zhai R; Yang Z
J Comput Assist Tomogr; 2015; 39(6):981-5. PubMed ID: 26196347
[TBL] [Abstract][Full Text] [Related]
4. [A quick solution for lumbar vertebra CT values in different ages and its clinical significance].
Xuan PF; Zhang G; Huang W; Ke L; Huang H; Li S
Nan Fang Yi Ke Da Xue Xue Bao; 2014 Dec; 34(12):1799-803. PubMed ID: 25537906
[TBL] [Abstract][Full Text] [Related]
5. The environmental density artifact: a beam-hardening effect in computed tomography.
Rao PS; Alfidi RJ
Radiology; 1981 Oct; 141(1):223-7. PubMed ID: 7291529
[TBL] [Abstract][Full Text] [Related]
6. The apical artifact: elevated attenuation values toward the apex of the skull.
Di Chiro G; Brooks RA; Dubal L; Chew E
J Comput Assist Tomogr; 1978 Jan; 2(1):65-70. PubMed ID: 670474
[TBL] [Abstract][Full Text] [Related]
7. [Radiation exposure in whole body and cranial CT studies in relation to parameters of the examination technic].
Fiebach BJ; Ewen K; Makoski HB
Computertomographie; 1983 Sep; 3(3):108-11. PubMed ID: 6640578
[TBL] [Abstract][Full Text] [Related]
8. An inaccuracy in computed tomography: the energy dependence of CT values.
Zatz LM; Alvarez RE
Radiology; 1977 Jul; 124(1):91-7. PubMed ID: 866662
[TBL] [Abstract][Full Text] [Related]
9. Characterization and correction of beam-hardening artifacts during dynamic volume CT assessment of myocardial perfusion.
Kitagawa K; George RT; Arbab-Zadeh A; Lima JA; Lardo AC
Radiology; 2010 Jul; 256(1):111-8. PubMed ID: 20574089
[TBL] [Abstract][Full Text] [Related]
10. [Material selective imaging and density measurement with the dual energy method. III. Determination of bone mineral of the spine with CT].
Kalender W; Felsenberg D; Süss C
Digitale Bilddiagn; 1987 Dec; 7(4):170-6. PubMed ID: 3436119
[TBL] [Abstract][Full Text] [Related]
11. Interphantom and interscanner variations for Hounsfield units--establishment of reference values for HU in a commercial QA phantom.
Sande EP; Martinsen AC; Hole EO; Olerud HM
Phys Med Biol; 2010 Sep; 55(17):5123-35. PubMed ID: 20714048
[TBL] [Abstract][Full Text] [Related]
12. Mass estimates by computed tomography: physical density from CT numbers.
Mull RT
AJR Am J Roentgenol; 1984 Nov; 143(5):1101-4. PubMed ID: 6333158
[TBL] [Abstract][Full Text] [Related]
13. Determination of the weighted CT dose index in modern multi-detector CT scanners.
Perisinakis K; Damilakis J; Tzedakis A; Papadakis A; Theocharopoulos N; Gourtsoyiannis N
Phys Med Biol; 2007 Nov; 52(21):6485-95. PubMed ID: 17951857
[TBL] [Abstract][Full Text] [Related]
14. Experimental assessment of the influence of beam hardening filters on image quality and patient dose in volumetric 64-slice X-ray CT scanners.
Ay MR; Mehranian A; Maleki A; Ghadiri H; Ghafarian P; Zaidi H
Phys Med; 2013 May; 29(3):249-60. PubMed ID: 22541061
[TBL] [Abstract][Full Text] [Related]
15. Beam hardening artefacts in computed tomography with photon counting, charge integrating and energy weighting detectors: a simulation study.
Shikhaliev PM
Phys Med Biol; 2005 Dec; 50(24):5813-27. PubMed ID: 16333157
[TBL] [Abstract][Full Text] [Related]
16. Cone beam computerized tomography: the effect of calibration of the Hounsfield unit number to electron density on dose calculation accuracy for adaptive radiation therapy.
Hatton J; McCurdy B; Greer PB
Phys Med Biol; 2009 Aug; 54(15):N329-46. PubMed ID: 19590116
[TBL] [Abstract][Full Text] [Related]
17. Superiority of synchrony of 256-slice cone beam computed tomography for acquiring pulsating objects. Comparison with conventional multislice computed tomography.
Funabashi N; Mizuno N; Yoshida K; Tsunoo T; Mori S; Tanada S; Endo M; Komuro I
Int J Cardiol; 2007 Jun; 118(3):400-5. PubMed ID: 17052785
[TBL] [Abstract][Full Text] [Related]
18. The importance of spectral separation: an assessment of dual-energy spectral separation for quantitative ability and dose efficiency.
Krauss B; Grant KL; Schmidt BT; Flohr TG
Invest Radiol; 2015 Feb; 50(2):114-8. PubMed ID: 25373305
[TBL] [Abstract][Full Text] [Related]
19. [Growing process of a vertebra in negative bone scintigram].
Pilz D; Fischer-Düsterhoff H; Vogel H
Z Orthop Ihre Grenzgeb; 1986; 124(1):77-8. PubMed ID: 3962444
[TBL] [Abstract][Full Text] [Related]
20. Shielding artificially increases the attenuation of water: study of CT gradient attenuation induced by shielding (CT GAINS).
Goldin D; Emerson S; Farah MC; Sokhandon F; Nandalur KR; Kumar S; Mezwa DG
Acad Radiol; 2013 Feb; 20(2):231-7. PubMed ID: 22981602
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]