These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
149 related articles for article (PubMed ID: 7188342)
1. Properties of Dextrostix. Dean B; North SE; Harrison LC; Martin FI Diabetes Care; 1982; 5(5):554-5. PubMed ID: 7188342 [No Abstract] [Full Text] [Related]
3. A comparison of blood glucose determination by a quick strip and glucose oxidase methods. Parikh SC; Mistry KP; Acharya PT Indian J Pathol Microbiol; 1983 Jan; 26(1):45-8. PubMed ID: 6642607 [No Abstract] [Full Text] [Related]
4. Screening for hypoglycemia with plasma in neonatal blood of high hematocrit value. Kaplan M; Blondheim O; Alon I; Eylath U; Trestian S; Eidelman AI Crit Care Med; 1989 Mar; 17(3):279-82. PubMed ID: 2920565 [TBL] [Abstract][Full Text] [Related]
5. Self-monitoring of blood glucose: an evaluation of the BM test glycemie 20-800 system. Scott RS N Z Med J; 1981 May; 93(684):340-1. PubMed ID: 6942295 [TBL] [Abstract][Full Text] [Related]
6. Reliability of present-day glucose test strips in the neonatal settings of a developing country. Taha SA; Babiker MA Ann Trop Paediatr; 1985 Jun; 5(2):73-5. PubMed ID: 2409909 [TBL] [Abstract][Full Text] [Related]
8. A clinical comparison of the performance of four blood glucose reagent strips. Cheeley RD; Joyce SM Am J Emerg Med; 1990 Jan; 8(1):11-5. PubMed ID: 2293826 [TBL] [Abstract][Full Text] [Related]
9. [Rapid determination of blood sugar using Dextrostix reactive strips and the reflectance meter]. Slama G; Hautecouverture M; Assan R; Eschwege E; Tchobroutsky G Pathol Biol (Paris); 1974 Jan; 22(1):99-106. PubMed ID: 4592419 [No Abstract] [Full Text] [Related]
10. Evaluation of an improved Reagent Strip system for measuring blood glucose. Davis AE Am J Med Technol; 1976 Jan; 42(1):48-51. PubMed ID: 1247025 [TBL] [Abstract][Full Text] [Related]
11. Bedside blood glucose determinations in critical care medicine: a comparative analysis of two techniques. Chernow B; Diaz M; Cruess D; Balestrieri F; Uddin D; Rainey TG; O'Brian JT Crit Care Med; 1982 Jul; 10(7):463-5. PubMed ID: 7083872 [TBL] [Abstract][Full Text] [Related]
12. Sources of error in glucose determinations in neonatal blood by glucose oxidase methods, including Dextrostix. Fox RE; Redstone D Am J Clin Pathol; 1976 Oct; 66(4):658-66. PubMed ID: 970367 [TBL] [Abstract][Full Text] [Related]
13. Tear glucose estimation--an alternative to blood glucose estimation. Das BN; Sengupta S; Das BK; Goswami NR J Indian Med Assoc; 1995 Apr; 93(4):127-8. PubMed ID: 8699035 [TBL] [Abstract][Full Text] [Related]
14. Dextrostix as a quantitative test for glucose in whole blood. Krynski IA; Logan JE Can Med Assoc J; 1967 Oct; 97(17):1006-11. PubMed ID: 6052898 [No Abstract] [Full Text] [Related]
15. [Comparison of blood sugar measured by Hoffman's, glucose oxidase and dextrostix technics during the oral glucose tolerance test]. Gay G; Mejean L; Debry G Pathol Biol (Paris); 1975 Oct; 23(8):623-8. PubMed ID: 1101161 [TBL] [Abstract][Full Text] [Related]
16. [Clinical applicability of an enzyme micromethod for the rapid determination of blood sugar]. Maj F; Cristini P; Baraldi B; Angeli G Minerva Med; 1976 Sep; 67(40):2605-9. PubMed ID: 967336 [TBL] [Abstract][Full Text] [Related]
17. Comparison of blood glucose testing using reagent strips with and without a meter (Chemstrips bG and Dextrostix/Dextrometer). Kubilis P; Rosenbloom AL; Lezotte D; Silverstein JH; Cimino P; Rosenbloom ED; Harvey C Diabetes Care; 1981; 4(3):417-9. PubMed ID: 7344891 [No Abstract] [Full Text] [Related]
18. [Test-strip method for the assessment of blood sugar. Utilization and possibilities of error]. Berger W Dtsch Med Wochenschr; 1973 Nov; 98(47):2252-3. PubMed ID: 4759522 [No Abstract] [Full Text] [Related]
19. [Blood sample dilution for measuring hyperglycemia using reagent strips]. Frati-Munari AC; García-Centeno J; Oseguera-Valladares R; de la Riva-Pinal H; Flores-Sobrevilla A; Lechuga-Gómez E Gac Med Mex; 1982 Jan; 118(1):24-7. PubMed ID: 7084576 [No Abstract] [Full Text] [Related]
20. EVALUATION OF THE RAPID DEXTROSTIX METHOD FOR DETERMINATION OF BLOOD GLUCOSE. PAWLIGER DF; SHIPP JC J Fla Med Assoc (1914); 1965 Sep; 52():641-3. PubMed ID: 14343577 [No Abstract] [Full Text] [Related] [Next] [New Search]