153 related articles for article (PubMed ID: 7196411)
1. Biological responses of the bovine teat to milking: information from measurements of milk flow-rate within single pulsation cycles.
Williams DM; Mein GA; Brown MR
J Dairy Res; 1981 Feb; 48(1):7-21. PubMed ID: 7196411
[TBL] [Abstract][Full Text] [Related]
2. A method for assessing teatcup liner performance during the peak milk flow period.
Penry JF; Upton J; Leonardi S; Thompson PD; Reinemann DJ
J Dairy Sci; 2018 Jan; 101(1):649-660. PubMed ID: 29102142
[TBL] [Abstract][Full Text] [Related]
3. Reduced liner-open phase and vacuum instead of prestimulation increase parlor efficiency in dairy cows.
Tuor M; Jenni B; Wellnitz O; Bruckmaier RM
J Dairy Sci; 2022 Feb; 105(2):1533-1541. PubMed ID: 34955277
[TBL] [Abstract][Full Text] [Related]
4. Compressive load applied by the teatcup liner to the bovine teat.
Mein GA; Williams DM; Thiel CC
J Dairy Res; 1987 Aug; 54(3):327-37. PubMed ID: 3655068
[TBL] [Abstract][Full Text] [Related]
5. Cyclic pressure applied to cows' teats by teatcup liners can be determined simply and noninvasively.
Thompson PD; Dzidic A; Mein GA; Penry JF; Sanford SA; Reinemann DJ
J Dairy Sci; 2021 Feb; 104(2):1881-1886. PubMed ID: 33309351
[TBL] [Abstract][Full Text] [Related]
6. Effect of pulsation rest phase duration on teat end congestion.
Upton J; Penry JF; Rasmussen MD; Thompson PD; Reinemann DJ
J Dairy Sci; 2016 May; 99(5):3958-3965. PubMed ID: 26947293
[TBL] [Abstract][Full Text] [Related]
7. Factors affecting mouthpiece chamber vacuum in machine milking.
Borkhus M; Rønningen O
J Dairy Res; 2003 Aug; 70(3):283-8. PubMed ID: 12916822
[TBL] [Abstract][Full Text] [Related]
8. The effect of manual and mechanical stimulation on oxytocin release and milking characteristics in Holstein cows milked 3 times daily.
Watters RD; Bruckmaier RM; Crawford HM; Schuring N; Schukken YH; Galton DM
J Dairy Sci; 2015 Mar; 98(3):1721-9. PubMed ID: 25582591
[TBL] [Abstract][Full Text] [Related]
9. The effect of pulsation ratio on teat condition, milk somatic cell count and productivity in dairy cows in automatic milking.
Ferneborg S; Svennersten-Sjaunja K
J Dairy Res; 2015 Nov; 82(4):453-9. PubMed ID: 26411595
[TBL] [Abstract][Full Text] [Related]
10. Technical note: Reduced pulsation chamber vacuum at normal pulsation rate and ratio provides adequate prestimulation to induce oxytocin release and milk ejection while simultaneous milk flow is prevented.
Neuheuser AL; Belo C; Bruckmaier RM
J Dairy Sci; 2017 Oct; 100(10):8609-8613. PubMed ID: 28822550
[TBL] [Abstract][Full Text] [Related]
11. Milk flow-dependent vacuum loss in high-line milking systems: effects on milking characteristics and teat tissue condition.
Ambord S; Bruckmaier RM
J Dairy Sci; 2010 Aug; 93(8):3588-94. PubMed ID: 20655427
[TBL] [Abstract][Full Text] [Related]
12. Effects of a latency period between pre-stimulation and teat cup attachment and periodic vacuum reduction on milking characteristics and teat condition in dairy cows.
Vetter A; van Dorland HA; Youssef M; Bruckmaier RM
J Dairy Res; 2014 Feb; 81(1):107-12. PubMed ID: 24433587
[TBL] [Abstract][Full Text] [Related]
13. Influence of pulsationless milking on teat canal keratin growth and turnover.
Lacy-Hulbert SJ; Hillerton JE; Woolford MW
J Dairy Res; 1996 Nov; 63(4):517-24. PubMed ID: 8933303
[TBL] [Abstract][Full Text] [Related]
14. Milk flow-controlled changes of pulsation ratio and pulsation rate affect milking characteristics in dairy cows.
Ambord S; Bruckmaier RM
J Dairy Res; 2009 Aug; 76(3):272-7. PubMed ID: 19250576
[TBL] [Abstract][Full Text] [Related]
15. Review: Milking machine settings, teat condition and milking efficiency in dairy cows.
Odorčić M; Rasmussen MD; Paulrud CO; Bruckmaier RM
Animal; 2019 Jul; 13(S1):s94-s99. PubMed ID: 31280747
[TBL] [Abstract][Full Text] [Related]
16. Teat thickness changes may provide biological test for effective pulsation.
Hamann J; Mein GA
J Dairy Res; 1996 May; 63(2):179-89. PubMed ID: 8861342
[TBL] [Abstract][Full Text] [Related]
17. Effect of hydraulic milking on milking performance, teat condition and lipolysis.
Grindal RJ; Griffin TK
J Dairy Res; 1989 Feb; 56(1):45-53. PubMed ID: 2703561
[TBL] [Abstract][Full Text] [Related]
18. Different vacuum levels, vacuum reduction during low milk flow, and different cluster detachment levels affect milking performance and teat condition in dairy cows.
Stauffer C; Feierabend M; Bruckmaier RM
J Dairy Sci; 2020 Oct; 103(10):9250-9260. PubMed ID: 32747105
[TBL] [Abstract][Full Text] [Related]
19. Effects of milking, over-milking and vacuum levels on front and rear quarter teats in dairy cows.
Vierbauch T; Peinhopf-Petz W; Wittek T
J Dairy Res; 2021 Nov; 88(4):396-400. PubMed ID: 34924072
[TBL] [Abstract][Full Text] [Related]
20. The control of milk flow through the teats of dairy cows.
Butler MC; Hillerton JE; Grindal RJ
J Dairy Sci; 1992 Apr; 75(4):1019-24. PubMed ID: 1578016
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]