These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

196 related articles for article (PubMed ID: 7198415)

  • 1. Inadvertent change of volatile anesthetics in anesthesia machines.
    Karis JH; Menzel DB
    Anesth Analg; 1982 Jan; 61(1):53-5. PubMed ID: 7198415
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Vaporization of mixed anesthetic liquids.
    Bruce DL; Linde HW
    Anesthesiology; 1984 Apr; 60(4):342-6. PubMed ID: 6703388
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Observations on use of wrong agent in an anesthesia agent vaporizer.
    Block FE; Schulte GT
    J Clin Monit Comput; 1999 Jan; 15(1):57-61. PubMed ID: 12578063
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [A mistake in the filling of a vaporizer detected by an infrared analyser of halogenated anesthetic agents].
    Baras E; Deriaz H; Lienhart A
    Ann Fr Anesth Reanim; 1989; 8(2):128-30. PubMed ID: 2735569
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A comparison of keyed and non-keyed vaporizer filling modes and volatile agent wastage.
    Uncles DR
    Anaesthesia; 1993 Sep; 48(9):795-8. PubMed ID: 8214502
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A comparison of the accuracy of the Siemens injection vaporizer and the Enfluratec 3 vaporizer.
    Cozanitis DA; Rosenberg PH; Merrett JD
    Anaesthesiol Reanim; 1994; 19(3):75-7. PubMed ID: 8086093
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Vaporizer malfunction--a cause of high concentration halothane vapor delivery].
    Yamada T; Masuda J; Takeda J; Sekiguchi H; Fukushima K
    Masui; 1994 Mar; 43(3):421-5. PubMed ID: 8182893
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [Accidental anesthetic overdose caused by anesthesia respirators Servo 900 C and D].
    Sticher J; Müller M; Zeiler D; Jung HJ; Hemplemann G
    Anasthesiol Intensivmed Notfallmed Schmerzther; 1994 May; 29(3):163-4. PubMed ID: 8043716
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Assessment of vaporizer performance in low-flow and closed-circuit anesthesia.
    Lin CY
    Anesth Analg; 1980 May; 59(5):359-66. PubMed ID: 6989290
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [Monochromatic infrared halogenated gas analyzer and handling errors].
    Baras E; Deriaz H; Lienhart A
    Ann Fr Anesth Reanim; 1992; 11(1):43-7. PubMed ID: 1443815
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Enflurane anesthesia in the pony: a comparative study between enflurane and halothane.
    Orsini JA; Taylor JI
    Cornell Vet; 1980 Jan; 70(1):50-66. PubMed ID: 7379554
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Evaluation of anesthetic vaporizers: application of the Normac infrared anesthetic agent monitor AA 102].
    Nishioka K; Hoshi K; Takahashi S
    Masui; 1987 May; 36(5):778-83. PubMed ID: 3656647
    [No Abstract]   [Full Text] [Related]  

  • 13. Chemistry of halothane-enflurane mixtures applied to anesthesia.
    Korman B; Ritchie IM
    Anesthesiology; 1985 Aug; 63(2):152-6. PubMed ID: 4025864
    [TBL] [Abstract][Full Text] [Related]  

  • 14. An evaluation of gas density dependence of anaesthetic vaporizers.
    Prins L; Strupat J; Clement J; Knill RL
    Can Anaesth Soc J; 1980 Mar; 27(2):106-10. PubMed ID: 6767537
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Consequences of misfilling contemporary vaporizers with desflurane.
    Andrews JJ; Johnston RV; Kramer GC
    Can J Anaesth; 1993 Jan; 40(1):71-6. PubMed ID: 8425247
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Halothane hepatitis without halothane: role of inapparent circuit contamination and its prevention.
    Varma RR; Whitesell RC; Iskandarani MM
    Hepatology; 1985; 5(6):1159-62. PubMed ID: 4065821
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [A research on misfilling of inhalation anesthetics into vaporizers].
    Kumazawa T; Kashimoto S; Tanaka Y; Manabe M; Takashima S; Kinoshita H; Yamamoto I
    Masui; 1984 Aug; 33(8):882-8. PubMed ID: 6512960
    [No Abstract]   [Full Text] [Related]  

  • 18. The output of four modern vaporizers in the presence of helium.
    Loeb RG
    Can J Anaesth; 1992 Oct; 39(8):888-91. PubMed ID: 1288913
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Nitrous oxide increases enflurane concentrations delivered by Ethrane vaporizers.
    Nawaf K; Stoelting RK
    Anesth Analg; 1979; 58(1):30-2. PubMed ID: 571219
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Dysfunction of vaporizers and nitrous oxide: solubility or viscosity?].
    Deriaz H; Duranteau R; Lienhart A
    Ann Fr Anesth Reanim; 1994; 13(1):27-32. PubMed ID: 8092579
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.