These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

88 related articles for article (PubMed ID: 7204533)

  • 1. Sample extraction detector for the liquid chromatographic determination of secoverine in biological samples.
    Reddingius RJ; de Jong GJ; Brinkman UA; Frei RW
    J Chromatogr; 1981 Jan; 205(1):77-84. PubMed ID: 7204533
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Automated determination of drugs in blood samples after enzymatic hydrolysis using precolumn switching and post-column reaction detection.
    Werkhoven-Goewie CE; de Ruiter C; Brinkman UA; Frei RW; de Jong GJ; Little CJ; Stahel O
    J Chromatogr; 1983 Jan; 255():79-90. PubMed ID: 6345562
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Precolumn-venting plug technique for direct injection of untreated blood plasma samples into reversed-phase liquid chromatography systems.
    Daoud N; Arvidsson T; Wahlund KG
    J Chromatogr; 1987 Jan; 385():311-22. PubMed ID: 3558588
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A 96-well single-pot liquid-liquid extraction, hydrophilic interaction liquid chromatography-mass spectrometry method for the determination of muraglitazar in human plasma.
    Xue YJ; Liu J; Unger S
    J Pharm Biomed Anal; 2006 Jun; 41(3):979-88. PubMed ID: 16533587
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Assay of vecuronium in plasma using solid-phase extraction, high-performance liquid chromatography and post-column ion-pair extraction with fluorimetric detection.
    Paanakker JE; Thio JM; Van den Wildenberg HM; Kaspersen FM
    J Chromatogr; 1987 Oct; 421(2):327-35. PubMed ID: 2892850
    [TBL] [Abstract][Full Text] [Related]  

  • 6. On-line renewable solid-phase extraction hyphenated to liquid chromatography for the determination of UV filters using bead injection and multisyringe-lab-on-valve approach.
    Oliveira HM; Segundo MA; Lima JL; Miró M; Cerdà V
    J Chromatogr A; 2010 May; 1217(22):3575-82. PubMed ID: 20399441
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Determination of free formaldehyde in cosmetics containing formaldehyde-releasing preservatives by reversed-phase dispersive liquid-liquid microextraction and liquid chromatography with post-column derivatization.
    Miralles P; Chisvert A; Alonso MJ; Hernandorena S; Salvador A
    J Chromatogr A; 2018 Mar; 1543():34-39. PubMed ID: 29478830
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Determination of sub-nanogram amounts of dihydroergotamine in plasma and urine using liquid chromatography and fluorimetric detection with off-line and on-line solid-phase drug enrichment.
    Humbert H; Denouel J; Chervet JP; Lavene D; Kiechel JR
    J Chromatogr; 1987 Jul; 417(2):319-29. PubMed ID: 3654884
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A novel method for high preconcentration of ultra trace amounts of B₁, B₂, G₁ and G₂ aflatoxins in edible oils by dispersive liquid-liquid microextraction after immunoaffinity column clean-up.
    Afzali D; Ghanbarian M; Mostafavi A; Shamspur T; Ghaseminezhad S
    J Chromatogr A; 2012 Jul; 1247():35-41. PubMed ID: 22673813
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Fiber-based liquid-phase micro-extraction of mebeverine enantiomers followed by chiral high-performance liquid chromatography analysis and its application to pharmacokinetics study in rat plasma.
    Hatami M; Farhadi K; Tukmechi A
    Chirality; 2012 Aug; 24(8):634-9. PubMed ID: 22700279
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Automated reversed-phase chromatographic analysis of etoposide and teniposide in plasma by using on-line surfactant-mediated sample clean-up and column-switching.
    van Opstal MA; van der Horst FA; Holthuis JJ; van Bennekom WP; Bult A
    J Chromatogr; 1989 Oct; 495():139-51. PubMed ID: 2613799
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Direct, sensitive and selective detection of free fatty acids by high-performance liquid chromatography with post-column ion-pair extraction and absorbance detection.
    Lawrence JF; Charbonneau CF
    J Chromatogr; 1988 Jul; 445(1):189-97. PubMed ID: 3215970
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Dispersive liquid-liquid microextraction combined with semi-automated in-syringe back extraction as a new approach for the sample preparation of ionizable organic compounds prior to liquid chromatography.
    Melwanki MB; Fuh MR
    J Chromatogr A; 2008 Jul; 1198-1199():1-6. PubMed ID: 18513730
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Determination of ultra-trace organic acids in Masson pine (Pinus massoniana L.) by accelerated solvent extraction and liquid chromatography-tandem mass spectrometry.
    Wang S; Fan CQ; Wang P
    J Chromatogr B Analyt Technol Biomed Life Sci; 2015 Feb; 981-982():1-8. PubMed ID: 25594951
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Band broadening inside the chromatographic column: the interest of a liquid stationary phase.
    Berthod A
    J Chromatogr A; 2006 Sep; 1126(1-2):347-56. PubMed ID: 16759661
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Liquid chromatographic determination of tetracycline in plasma and urine.
    Eksborg S; Ehrsson H; Lönroth U
    J Chromatogr; 1979 Dec; 185():583-91. PubMed ID: 546934
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Green and simple analytical method to determine benzimidazoles in milk samples by using salting-out assisted liquid-liquid extraction and capillary liquid chromatography.
    Tejada-Casado C; Del Olmo-Iruela M; García-Campaña AM; Lara FJ
    J Chromatogr B Analyt Technol Biomed Life Sci; 2018 Aug; 1091():46-52. PubMed ID: 29852381
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Eco-friendly ionic liquid based ultrasonic assisted selective extraction coupled with a simple liquid chromatography for the reliable determination of acrylamide in food samples.
    Albishri HM; El-Hady DA
    Talanta; 2014 Jan; 118():129-36. PubMed ID: 24274280
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Microfluidic liquid-liquid extraction system based on stopped-flow technique and liquid core waveguide capillary.
    Sun M; Du WB; Fang Q
    Talanta; 2006 Sep; 70(2):392-6. PubMed ID: 18970781
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Determination of urapidil and its metabolites in human serum and urine: comparison of liquid-liquid and fully automated liquid-solid extraction.
    Zech K; Huber R
    J Chromatogr; 1986 Feb; 353():351-60. PubMed ID: 3700520
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.