These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
87 related articles for article (PubMed ID: 7214712)
1. An evaluation of the temperature control system of the Centrifichem 400. McDowell TL; Passey RB; Fowler MW Clin Chim Acta; 1981 Feb; 110(1):35-43. PubMed ID: 7214712 [TBL] [Abstract][Full Text] [Related]
2. The temperature control system of the Cobas-Bio centrifugal analyzer. Miller WG; Smith DR Am J Clin Pathol; 1983 Dec; 80(6):867-70. PubMed ID: 6195917 [TBL] [Abstract][Full Text] [Related]
3. Infrared, thermistor, and glass-mercury thermometry for measurement of body temperature in children with cancer. Shenep JL; Adair JR; Hughes WT; Roberson PK; Flynn PM; Brodkey TO; Fullen GH; Kennedy WT; Oakes LL; Marina NM Clin Pediatr (Phila); 1991 Apr; 30(4 Suppl):36-41; discussion 49. PubMed ID: 2029817 [TBL] [Abstract][Full Text] [Related]
4. Comparing mercury-in-glass, tympanic and disposable thermometers in measuring body temperature in healthy young people. Khorshid L; Eşer I; Zaybak A; Yapucu U J Clin Nurs; 2005 Apr; 14(4):496-500. PubMed ID: 15807757 [TBL] [Abstract][Full Text] [Related]
5. Precision of a new thermometer for rapid rectal temperature measurement in neonates. Dollberg S; Lahav S; Mimouni FB Am J Perinatol; 2001; 18(2):103-5. PubMed ID: 11383699 [TBL] [Abstract][Full Text] [Related]
6. Evaluation of a new thermometer for rapid axillary temperature measurement in preterm infants. Dollberg S; Mincis L; Mimouni FB; Ashbel G; Barak M Am J Perinatol; 2003 May; 20(4):201-4. PubMed ID: 12874731 [TBL] [Abstract][Full Text] [Related]
8. Comparison of temperature measurements by an aural infrared thermometer with measurements by traditional rectal and axillary techniques. Yetman RJ; Coody DK; West MS; Montgomery D; Brown M J Pediatr; 1993 May; 122(5 Pt 1):769-73. PubMed ID: 8496759 [TBL] [Abstract][Full Text] [Related]
9. Measurement accuracy of fever by tympanic and axillary thermometry. Devrim I; Kara A; Ceyhan M; Tezer H; Uludağ AK; Cengiz AB; Yiğitkanl I; Seçmeer G Pediatr Emerg Care; 2007 Jan; 23(1):16-9. PubMed ID: 17228215 [TBL] [Abstract][Full Text] [Related]
10. [Only rectal temperature measurements are suitable for routine temperature measurement]. Jensen BN; Jeppesen LJ; Mortensen BB Ugeskr Laeger; 1991 Dec; 153(50):3546-9. PubMed ID: 1776195 [TBL] [Abstract][Full Text] [Related]
11. [An alternative to rectal measurement of body temperature with a mercury thermometer]. Ottesen MM Ugeskr Laeger; 1991 Dec; 153(50):3544-5. PubMed ID: 1776194 [TBL] [Abstract][Full Text] [Related]
12. [Infrared tympanic thermometry compared to mercury thermometers]. Valle PC; Kildahl-Andersen O; Steinvoll K Tidsskr Nor Laegeforen; 2000 Jan; 120(1):15-7. PubMed ID: 10815472 [TBL] [Abstract][Full Text] [Related]
13. Oral temperature differences in relation to thermometer and technique. Erickson R Nurs Res; 1980; 29(3):157-64. PubMed ID: 6901014 [TBL] [Abstract][Full Text] [Related]
14. An analysis of the effect of thermometer type and make on rectal temperature measurements of cattle, horses and sheep. Hine L; Laven RA; Sahu SK N Z Vet J; 2015 May; 63(3):171-3. PubMed ID: 25263731 [TBL] [Abstract][Full Text] [Related]
15. [Temperature measurement in the ear canal: comparison of an infrared thermometer with conventional temperature probes and evaluation of clinical factors on infrared measurement]. Rohrberg M; Fritz U; Weyland W; Braun U Anasthesiol Intensivmed Notfallmed Schmerzther; 1997 Jul; 32(7):409-13. PubMed ID: 9340028 [TBL] [Abstract][Full Text] [Related]
16. [The tympanic thermometer in pediatrics as an alternative to the mercury-in-glass thermometer]. Vertedor-Hurtado MV; Padín-López S; Carreira-Pastor MJ; López-Martínez JM Enferm Clin; 2009; 19(3):115-20. PubMed ID: 19386529 [TBL] [Abstract][Full Text] [Related]
17. Accuracy of an infrared tympanic thermometer. Amoateng-Adjepong Y; Del Mundo J; Manthous CA Chest; 1999 Apr; 115(4):1002-5. PubMed ID: 10208200 [TBL] [Abstract][Full Text] [Related]
18. The gallium melting-point standard: its role in manufacture and quality control of electronic thermometers for the clinical laboratory. Sostman HE Clin Chem; 1977; 23(4):725-32. PubMed ID: 844168 [TBL] [Abstract][Full Text] [Related]
19. Factors affecting rectal temperature measurement using commonly available digital thermometers. Naylor JM; Streeter RM; Torgerson P Res Vet Sci; 2012 Feb; 92(1):121-3. PubMed ID: 21147490 [TBL] [Abstract][Full Text] [Related]
20. Is the axilla the right site for temperature measurement in children by chemical thermometer? Kara A; Devrim I; Cengiz AB; Celik F; Tezer H; Uludağ AK; Seçmeer G Turk J Pediatr; 2009; 51(4):325-7. PubMed ID: 19950838 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]