These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
131 related articles for article (PubMed ID: 7218779)
1. Improved cold-vapor atomic absorption technique for the microdetermination of total and inorganic mercury in biological samples. Farant JP; Brissette D; Moncion L; Bigras L; Chartrand A J Anal Toxicol; 1981; 5(1):47-51. PubMed ID: 7218779 [TBL] [Abstract][Full Text] [Related]
2. Studies on mercury pollution: microdetermination of mercury in biological materials by cold vapour atomic absorption spectrometry. Shrivastava AK; Tandon SG Int J Environ Anal Chem; 1982; 11(3-4):221-6. PubMed ID: 7107114 [TBL] [Abstract][Full Text] [Related]
3. Atomic absorption spectrophotometric microdetermination of total mercury in undigested biological samples. Ngim CH; Foo SC; Phoon WO J Anal Toxicol; 1988; 12(3):132-5. PubMed ID: 3386207 [TBL] [Abstract][Full Text] [Related]
4. Determination of total mercury in human hair samples by cold vapor atomic absorption spectrometry. Pineau A; Piron M; Boiteau HL; Etourneau MJ; Guillard O J Anal Toxicol; 1990; 14(4):235-8. PubMed ID: 2395346 [TBL] [Abstract][Full Text] [Related]
5. Routine, automated determination of inorganic and total mercury in multimedia using cold vapour atomic absorption spectrometry. Gill U; Bigras L; Schwartz H Chemosphere; 2004 Sep; 56(11):1097-103. PubMed ID: 15276722 [TBL] [Abstract][Full Text] [Related]
6. Multivessel system for cold-vapor mercury generation. Determination of mercury in hair and fish. Boaventura GR; Barbosa AC; East GA Biol Trace Elem Res; 1997; 60(1-2):153-61. PubMed ID: 9404685 [TBL] [Abstract][Full Text] [Related]
7. Modification of a reaction vessel for the determination of total mercury in hair by cold vapor atomic absorption spectrometry. Pereira EF; SouzaDe JR Biol Trace Elem Res; 2009 Sep; 130(3):210-7. PubMed ID: 19214396 [TBL] [Abstract][Full Text] [Related]
8. Accuracy and precision of the determination of mercury in human scalp hair by cold-vapour atomic-absorption spectrophotometry. McMullin JF; Pritchard JG; Sikondari AH Analyst; 1982 Jul; 107(1276):803-14. PubMed ID: 7125233 [No Abstract] [Full Text] [Related]
9. Elimination of the matrix effect in the cold-vapor atomic absorption analysis of mercury in human hair samples. Wigfield DC; Croteau SM; Perkins SL J Anal Toxicol; 1981; 5(1):52-5. PubMed ID: 7218780 [TBL] [Abstract][Full Text] [Related]
10. Rapid digestion and flameless atomic absorption spectroscopy of mercury in fish. Dusci LJ; Hackett LP J Assoc Off Anal Chem; 1976 Sep; 59(5):1183-5. PubMed ID: 987033 [TBL] [Abstract][Full Text] [Related]
11. Determination of mercury in fish tissue using a minianalyzer based on cold vapor atomic absorption spectrometry at the 184.9 nm line. Rizea MC; Bratu MC; Danet AF; Bratu A Anal Sci; 2007 Sep; 23(9):1121-5. PubMed ID: 17878589 [TBL] [Abstract][Full Text] [Related]
12. A detailed study of thermal decomposition, amalgamation/ atomic absorption spectrophotometry methodology for the quantitative analysis of mercury in fish and hair. Butala SJ; Scanlan LP; Chaudhuri SN J Food Prot; 2006 Nov; 69(11):2720-8. PubMed ID: 17133817 [TBL] [Abstract][Full Text] [Related]
13. A stationary cold-vapor technique for the determination of submicrogram amounts of mercury in biological tissues by flameless atomic absorption spectrophotometry. Bourcier DR; Sharma RP J Anal Toxicol; 1981; 5(2):65-8. PubMed ID: 7242023 [TBL] [Abstract][Full Text] [Related]
14. Stationary cold-vapor atomic absorption spectrometric attachment for determination of total mercury in undigested fish samples. Tong SL; Leow WK Anal Chem; 1980 Mar; 52(3):581-3. PubMed ID: 7396197 [No Abstract] [Full Text] [Related]
15. The effect of experimental parameters on the cold-vapor mercury atomic absorption determination. Speciation analysis of sulfhydryl-bound mercury. Daniels RS; Wigfield DC J Anal Toxicol; 1989; 13(4):214-7. PubMed ID: 2779173 [TBL] [Abstract][Full Text] [Related]
16. The matrix effect in the cold-vapor atomic absorption analysis of mercury in various biological tissues. Wigfield DC; Eatock SA J Anal Toxicol; 1987; 11(4):137-9. PubMed ID: 3626524 [TBL] [Abstract][Full Text] [Related]
17. Inorganic, organic, and total mercury in blood and urine: cold vapor analysis with automated flow injection sample delivery. Nixon DE; Mussmann GV; Moyer TP J Anal Toxicol; 1996; 20(1):17-22. PubMed ID: 8837946 [TBL] [Abstract][Full Text] [Related]
18. Simplified apparatus for determination of mercury by atomic absorption and inductively coupled plasma emission spectroscopy. Suddendorf RF; Watts JO; Boyer K J Assoc Off Anal Chem; 1981 Sep; 64(5):1105-10. PubMed ID: 7287608 [TBL] [Abstract][Full Text] [Related]
19. Modified determination of total and inorganic mercury in urine by cold vapor atomic absorption sectrometry. Littlejohn D; Fell GS; Ottaway JM Clin Chem; 1976 Oct; 22(10):1719-23. PubMed ID: 975519 [TBL] [Abstract][Full Text] [Related]
20. Use of a solution cathode glow discharge for cold vapor generation of mercury with determination by ICP-atomic emission spectrometry. Zhu Z; Chan GC; Ray SJ; Zhang X; Hieftje GM Anal Chem; 2008 Sep; 80(18):7043-50. PubMed ID: 18710258 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]