These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

122 related articles for article (PubMed ID: 7224140)

  • 1. [A simple method for determination of the functional residual capacity during artificial ventilation (author's transl)].
    Stokke T; Hensel I; Burchardi H
    Anaesthesist; 1981 Mar; 30(3):124-30. PubMed ID: 7224140
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Measurement of functional residual capacity of the lung by partial CO2 rebreathing method during acute lung injury in animals.
    Brewer LM; Haryadi DG; Orr JA
    Respir Care; 2007 Nov; 52(11):1480-9. PubMed ID: 17971251
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [Determination of pulmonary diffusing capacity during artificial ventilation (author's transl)].
    Stokke T; Röhrborn W; Hensel I; Hilfiker O; Braun U; Burchardi H
    Anaesthesist; 1981 Dec; 30(12):602-9. PubMed ID: 7332088
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Pulmonary diffusing capacity for carbon monoxide by rebreathing in mechanically ventilated patients.
    Burchardi H; Stokke T
    Bull Eur Physiopathol Respir; 1985; 21(3):263-73. PubMed ID: 3890988
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [A simple helium-dilution method for the determination of functional residual capacity in artificially ventilated patients (author's transl)].
    Rung I; Kämmerer H; Klaschik E
    Anaesthesist; 1980 Mar; 29(3):148-51. PubMed ID: 6769355
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Measurement of functional residual capacity and pulmonary carbon monoxide diffusing capacity during mechanical ventilation with PEEP.
    Kondo T; Kurata T; Takasaki Y; Ohta Y; Yamabayashi H
    Tokai J Exp Clin Med; 1982 Sep; 7(5):561-73. PubMed ID: 6763783
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Measurements of functional residual capacity during intensive care treatment: the technical aspects and its possible clinical applications.
    Heinze H; Eichler W
    Acta Anaesthesiol Scand; 2009 Oct; 53(9):1121-30. PubMed ID: 19681779
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Measurement of functional residual capacity by sulfur hexafluoride in small-volume lungs during spontaneous breathing and mechanical ventilation.
    Schulze A; Schaller P; Töpfer A; Kirpalani H
    Pediatr Res; 1994 Apr; 35(4 Pt 1):494-9. PubMed ID: 8047388
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Cardiopulmonary effects of CPPV (continuous positive pressure ventilation) and IRV (inverse ratio ventilation) in experimental myocardial ischemia].
    Hachenberg T; Meyer J; Sielenkämper A; Kraft W; Vogt B; Breithardt G; Lawin P
    Anaesthesist; 1993 Apr; 42(4):210-20. PubMed ID: 8488992
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [Measurement of functional residual capacity by nitrogen washout during mechanical ventilation].
    Nomura T; Saito Y; Ogawa H; Akata N; Nishino Y; Kosaka Y
    Masui; 1998 Feb; 47(2):174-9. PubMed ID: 9513330
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Behavior of functional residual capacity in acute respiratory insufficiency].
    Langenstein H; Brunner J; Wolff G
    Schweiz Med Wochenschr; 1983 Aug; 113(33):1141-4. PubMed ID: 6623035
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Measurement of functional residual capacity by helium dilution during partial support ventilation: in vitro accuracy and in vivo precision of the method.
    Di Marco F; Rota Sperti L; Milan B; Stucchi R; Centanni S; Brochard L; Fumagalli R
    Intensive Care Med; 2007 Dec; 33(12):2109-15. PubMed ID: 17703280
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Positive end-expiratory pressure optimization using electric impedance tomography in morbidly obese patients during laparoscopic gastric bypass surgery.
    Erlandsson K; Odenstedt H; Lundin S; Stenqvist O
    Acta Anaesthesiol Scand; 2006 Aug; 50(7):833-9. PubMed ID: 16879466
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A modified helium dilution technique for measuring small lung gas volumes.
    Roy CH; Barnes RJ; Heath MF; Sensky PL
    J Dev Physiol; 1992 Feb; 17(2):87-92. PubMed ID: 1500637
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Functional residual capacity changes after different endotracheal suctioning methods.
    Heinze H; Sedemund-Adib B; Heringlake M; Gosch UW; Eichler W
    Anesth Analg; 2008 Sep; 107(3):941-4. PubMed ID: 18713910
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A practical procedure for measuring functional residual capacity during mechanical ventilation with or without PEEP.
    Weaver LJ; Pierson DJ; Kellie R; Bonner B; Craig KC
    Crit Care Med; 1981 Dec; 9(12):873-7. PubMed ID: 7032846
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Evaluation of a CO2 partial rebreathing functional residual capacity measurement method for use during mechanical ventilation.
    Brewer L; Orr J; Fulcher E; Markewitz B
    J Clin Monit Comput; 2011 Dec; 25(6):397-404. PubMed ID: 22057246
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Validation and clinical feasibility of nitrogen washin/washout functional residual capacity measurements in children.
    Olegård C; Søndergaard S; Pålsson J; Lundin S; Stenqvist O
    Acta Anaesthesiol Scand; 2010 Mar; 54(3):370-6. PubMed ID: 19839952
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Measuring functional residual capacity in normal and oleic acid-injured lungs.
    Gauger PG; Overbeck MC; Chambers SD; Weber ED; Hirschl RB
    J Surg Res; 1996 Jun; 63(1):204-8. PubMed ID: 8661198
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Functional residual capacity measurement by heptafluoropropane in ventilated newborn lungs: in vitro and in vivo validation.
    Proquitté H; Kusztrich A; Auwärter V; Pragst F; Wauer RR; Schmalisch G
    Crit Care Med; 2006 Jun; 34(6):1789-95. PubMed ID: 16625130
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.