These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
121 related articles for article (PubMed ID: 7224244)
1. Microprocessor control of intra-aortic balloon pumping. Philippe E; Clark JW; Lande A; Ellis JR Ann Biomed Eng; 1980; 8(3):209-24. PubMed ID: 7224244 [No Abstract] [Full Text] [Related]
2. Umbrella balloon for maximum unloading during intra-aortic balloon pumping. Anstadt GL; Schiff P Trans Am Soc Artif Intern Organs; 1981; 27():461-6. PubMed ID: 7331113 [No Abstract] [Full Text] [Related]
4. Differences between intra-aortic balloon pumps and their use. Hendrickx HH; Berkowitz D Crit Care Med; 1982 Nov; 10(11):796-7. PubMed ID: 7140322 [No Abstract] [Full Text] [Related]
5. A new guidable double lumen percutaneous intra-aortic balloon. Merav AD; Solomon N; Montefusco CM; Bregman D Trans Am Soc Artif Intern Organs; 1981; 27():593-7. PubMed ID: 7331137 [No Abstract] [Full Text] [Related]
6. [Experimental studies of the effect of intraaortic balloon pumping for asynergy due to acute myocardial infarction (author's transl)]. Nakamura T Nihon Kyobu Geka Gakkai Zasshi; 1980 Jun; 28(6):911-23. PubMed ID: 7410913 [No Abstract] [Full Text] [Related]
7. [Test of the "Biopulse-3" aortic balloon pumping apparatus]. Super NA; BelilovskiÄ MA; PriÄmak AA; Khrushchev AA; Belianin II Med Tekh; 1977; (6):20-5. PubMed ID: 593103 [TBL] [Abstract][Full Text] [Related]
8. A new percutaneous intra-aortic balloon. Bregman D Trans Am Soc Artif Intern Organs; 1980; 26():8-11. PubMed ID: 7245564 [TBL] [Abstract][Full Text] [Related]
9. Microprocessor-based controller for in-series cardiac assistance. Moore TW; Jaron D; Szydlowski GW Med Biol Eng Comput; 1982 Jul; 20(4):523-6. PubMed ID: 7132461 [No Abstract] [Full Text] [Related]
11. Automatic control of a series-parallel mechanical circulatory assist system in severe uni- or biventricular failure. Clark JW; Philippe E; Peterson R; Lande A; Ellis JR Ann Biomed Eng; 1980; 8(1):57-74. PubMed ID: 7458019 [No Abstract] [Full Text] [Related]
12. Improvement in intra-aortic balloon pumping and evaluation of its efficacy by electrode methods of control. Ioseliani GD; Chilaia SM Artif Organs; 1983 Feb; 7(1):92-100. PubMed ID: 6838411 [TBL] [Abstract][Full Text] [Related]
13. Preclinical evaluation of intra-aortic balloon pumping for pediatric use. Veasy LG; Blaylock RC; Daitoh N; Fukumasu H; Orth JL Trans Am Soc Artif Intern Organs; 1981; 27():490-4. PubMed ID: 7331117 [TBL] [Abstract][Full Text] [Related]
14. Clinical trial with a percutaneously inserted intra-aortic balloon pump: a wider spectrum of patient application. Phillips SJ; Gordon DF; Iannone L; Kongtahworn C; Beshany SE; Zeff RH; Zeff RL; Brown TM Thorac Cardiovasc Surg; 1980 Jun; 28(3):197-9. PubMed ID: 6156515 [TBL] [Abstract][Full Text] [Related]
15. Left ventricular and unidirectional intra-aortic balloon pumping. Effects on hemodynamics in canine cardiogenic shock. Bregman D; Parodi EN; Malm JR J Thorac Cardiovasc Surg; 1974 Nov; 68(5):677-86. PubMed ID: 4417377 [No Abstract] [Full Text] [Related]
16. A fluidic drive system for intra-aortic balloon heart assist device. Hariharan R; Menon KA IEEE Trans Biomed Eng; 1978 May; 25(3):301-3. PubMed ID: 680764 [No Abstract] [Full Text] [Related]
17. New controller for in-series cardiac-assist devices. Martin PJ; Jaron D Med Biol Eng Comput; 1978 May; 16(3):243-9. PubMed ID: 308125 [No Abstract] [Full Text] [Related]
19. A new left ventricular assist device: clinical experience in two patients. Phillips SJ; Kongtahworn C; Zeff RH; Iannone LA; Brown TM; Kreamer R; Gordon DF Med Instrum; 1980; 14(5):288-93. PubMed ID: 6450314 [TBL] [Abstract][Full Text] [Related]
20. Hemodynamic effects of intra-aortic balloon pumping in dogs with aortic incompetence. Yellin E; Levy L; Bregman D; Frater R Trans Am Soc Artif Intern Organs; 1973; 19():389-94. PubMed ID: 4722754 [No Abstract] [Full Text] [Related] [Next] [New Search]