These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
55 related articles for article (PubMed ID: 7226606)
1. Analysis of patterns of knee motion walking for four types of total knee implants. Rittman N; Kettelkamp DB; Pryor P; Schwartzkopf GL; Hillberry B Clin Orthop Relat Res; 1981; (155):111-7. PubMed ID: 7226606 [TBL] [Abstract][Full Text] [Related]
2. Flexion after total knee replacement. A comparison between the Medial Pivot knee and a posterior stabilised implant. Shakespeare D; Ledger M; Kinzel V Knee; 2006 Oct; 13(5):371-3. PubMed ID: 16828289 [TBL] [Abstract][Full Text] [Related]
4. [Restricted motion after total knee arthroplasty]. Kucera T; Urban K; Karpas K; Sponer P Acta Chir Orthop Traumatol Cech; 2007 Oct; 74(5):326-31. PubMed ID: 18001629 [TBL] [Abstract][Full Text] [Related]
5. [Initial experience with implantation of the cemented Beznoska/S.V.L. total knee joint endoprosthesis]. Kubes R; Dungl P; Podskubka A; Stĕdrý V Acta Chir Orthop Traumatol Cech; 2003; 70(1):39-46. PubMed ID: 12764950 [TBL] [Abstract][Full Text] [Related]
6. [Total knee arthroplasty with the Beznoska S.V.L. implant: short-term results]. Stárek M; Stehlík J; Held M Acta Chir Orthop Traumatol Cech; 2004; 71(6):352-9. PubMed ID: 15686636 [TBL] [Abstract][Full Text] [Related]
7. [Influence of preoperative range of motion on the early clinical outcome of total knee arthroplasty]. Shi MG; Lü HS; Guan ZP Zhonghua Wai Ke Za Zhi; 2006 Aug; 44(16):1101-5. PubMed ID: 17081464 [TBL] [Abstract][Full Text] [Related]
8. In vivo kinematic analysis of a high-flexion posterior stabilized fixed-bearing knee prosthesis in deep knee-bending motion. Tamaki M; Tomita T; Yamazaki T; Hozack WJ; Yoshikawa H; Sugamoto K J Arthroplasty; 2008 Sep; 23(6):879-85. PubMed ID: 18555651 [TBL] [Abstract][Full Text] [Related]
9. Coronal plane stability before and after total knee arthroplasty. Siston RA; Goodman SB; Delp SL; Giori NJ Clin Orthop Relat Res; 2007 Oct; 463():43-9. PubMed ID: 17621236 [TBL] [Abstract][Full Text] [Related]
10. Design features of total knees for achieving normal knee motion characteristics. Walker PS; Sussman-Fort JM; Yildirim G; Boyer J J Arthroplasty; 2009 Apr; 24(3):475-83. PubMed ID: 18534451 [TBL] [Abstract][Full Text] [Related]
11. [Bone morphing system for rotational alignment in total knee arthroplasty]. Wu H; van Driessche S; Goutallier D Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2008 Jan; 22(1):12-5. PubMed ID: 18361228 [TBL] [Abstract][Full Text] [Related]
12. Primary total knee arthroplasty in stiff and ankylosed knees. Montgomery WH; Insall JN; Haas SB; Becker MS; Windsor RE Am J Knee Surg; 1998; 11(1):20-3. PubMed ID: 9533049 [TBL] [Abstract][Full Text] [Related]
13. [Early clinical outcome of total knee arthroplasty for flexion-contracture deformity knees of different degrees]. Guan Z; Lv H; Shi M Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2006 Jun; 20(6):598-601. PubMed ID: 16827380 [TBL] [Abstract][Full Text] [Related]
14. In vivo kinematic analysis of a high-flexion, posterior-stabilized, mobile-bearing knee prosthesis in deep knee bending motion. Tamaki M; Tomita T; Watanabe T; Yamazaki T; Yoshikawa H; Sugamoto K J Arthroplasty; 2009 Sep; 24(6):972-8. PubMed ID: 19033084 [TBL] [Abstract][Full Text] [Related]
15. Tibiofemoral force following total knee arthroplasty: comparison of four prosthesis designs in vitro. Nicholls RL; Schirm AC; Jeffcote BO; Kuster MS J Orthop Res; 2007 Nov; 25(11):1506-12. PubMed ID: 17568418 [TBL] [Abstract][Full Text] [Related]
16. Three-dimensional pattern of knee movement in patients with gonarthrosis. Ogrodzka K; Chwała W; Niedźwiedzki T Ortop Traumatol Rehabil; 2007; 9(6):618-26. PubMed ID: 18227753 [TBL] [Abstract][Full Text] [Related]
17. Pre-surgery knee joint loading patterns during walking predict the presence and severity of anterior knee pain after total knee arthroplasty. Smith AJ; Lloyd DG; Wood DJ J Orthop Res; 2004 Mar; 22(2):260-6. PubMed ID: 15013083 [TBL] [Abstract][Full Text] [Related]
18. The effect of patella resurfacing in total knee arthroplasty on functional range of movement measured by flexible electrogoniometry. Myles CM; Rowe PJ; Nutton RW; Burnett R Clin Biomech (Bristol, Avon); 2006 Aug; 21(7):733-9. PubMed ID: 16603285 [TBL] [Abstract][Full Text] [Related]
19. The use of functional analysis in evaluating knee kinematics. Andriacchi TP; Dyrby CO; Johnson TS Clin Orthop Relat Res; 2003 May; (410):44-53. PubMed ID: 12771816 [TBL] [Abstract][Full Text] [Related]
20. Functional gait analysis of trans-femoral amputees using two different single-axis prosthetic knees with hydraulic swing-phase control: Kinematic and kinetic comparison of two prosthetic knees. Sapin E; Goujon H; de Almeida F; Fodé P; Lavaste F Prosthet Orthot Int; 2008 Jun; 32(2):201-18. PubMed ID: 18569888 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]