These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

105 related articles for article (PubMed ID: 7232378)

  • 1. [Determination of the polymorphism and aging of human serum albumin by an isofocusing method in a borate-polyol system].
    Azhitskií GIu; Akhmed M; Troitskiĭ GV
    Probl Gematol Pereliv Krovi; 1981 Mar; 26(3):40-2. PubMed ID: 7232378
    [No Abstract]   [Full Text] [Related]  

  • 2. [Two-dimensional electrophoresis of the products of limited hydrolysis of human serum albumin using isoelectric focusing in a borate-polyol system].
    Zagorul'ko GV; Azhitskiĭ GIu; Troitskiĭ GV
    Vopr Med Khim; 1987; 33(2):136-8. PubMed ID: 3604135
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [A method of isoelectric focusing in a borate-polyol system with pH gradient of 4.0 to 5.6 in a thin layer of polyacrylamide gel].
    Azhitskiĭ GIu; Zagorul'ko GV; Troitskiĭ GV
    Vopr Med Khim; 1987; 33(4):124-6. PubMed ID: 3660734
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Use of polyacrylamide gel for the purposes of isoelectric focusing in borate-polyol systems].
    Azhitskiĭ GIu; Akhmed M; Troitskiĭ GV
    Vopr Med Khim; 1980; 26(1):133-6. PubMed ID: 7368621
    [No Abstract]   [Full Text] [Related]  

  • 5. [Stable borate-polyol pH-gradients and isofocusing of proteins in the range of pH 3.0-9.0].
    Azhitskiĭ GIu; Petrenko VF; Klintsova SP; Troitskiĭ GV
    Ukr Biokhim Zh (1978); 1981; 53(4):6-14. PubMed ID: 7281256
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Isoelectric focusing in a boroborate buffer-mannitol system (BBM)].
    Troitskiĭ GV; Azhitskiĭ GIu; Malyi DD
    Vopr Med Khim; 1976; 22(2):282-6. PubMed ID: 16397
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Isoelectric focusing of human serum albumin in the boric-borate-buffer-mannitol system in the multicellular apparatus].
    Troitskiĭ GV; Azhitskiĭ GIu; Malyĭ KD
    Lab Delo; 1975; (12):708-12. PubMed ID: 57261
    [No Abstract]   [Full Text] [Related]  

  • 8. [Isolation and use of stable borate-polyol pH gradients in the range of 1.9-12.0 for isoelectric focusing of proteins and low-molecular compounds].
    Azhitskiĭ GIu; Sharaeva TK; Khirsa LN; Troitskiĭ GV
    Vopr Med Khim; 1984; 30(1):48-51. PubMed ID: 6710937
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Isolation and purification of an unspecific component from human serum albumin, typical for pathology].
    Troitskiĭ GV; Akhmed M; Azhitskiĭ GIu; Bagdasar'ian SN; Gaevskaia VA
    Vopr Med Khim; 1981; 27(2):166-72. PubMed ID: 7281554
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [Transient minor fractions of human serum albumin: physico-chemical properties].
    Azhitskiĭ GIu; Troitskiĭ GB; Sharaeva TK; Selivanova KF; Sokolova NN
    Vopr Med Khim; 1984; 30(5):50-5. PubMed ID: 6528520
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Nonamphoteric isoelectric focusing: II. Stability of borate-glycerol pH gradients in recycling isoelectric focusing.
    Todd P; Elsasser W
    Electrophoresis; 1990 Nov; 11(11):947-52. PubMed ID: 2079041
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Preparative free-flow isoelectric focusing: modeling and experiments.
    Poux M; Bertrand J
    Electrophoresis; 1990 Nov; 11(11):907-12. PubMed ID: 2079036
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Rapid and effective focusing in a carrier ampholyte solution isoelectric focusing system: a proteome prefractionation tool.
    Tran JC; Doucette AA
    J Proteome Res; 2008 Apr; 7(4):1761-6. PubMed ID: 18284188
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [A method of isoelectric focusing in a borate-polyol system for the detection of hemoglobin A1c].
    Korolev VA; Borisenko SN; Selivanova KF; Shchekolodkin VF
    Lab Delo; 1989; (1):61-2. PubMed ID: 2468034
    [No Abstract]   [Full Text] [Related]  

  • 15. [Characteristics of isoelectric fractions of human serum albumin].
    Bagdasar'ian SN; Malyĭ KD; Zarechnaia IP; Azhitskiĭ GIu; Akhmed M
    Ukr Biokhim Zh (1978); 1981; 53(4):15-8. PubMed ID: 7281248
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Synthesis of UV-absorbing and fluorescent carrier ampholyte mixtures and their application for the determination of the operational pH values of buffering membranes used in isoelectric trapping separations.
    North R; Hwang A; Lalwani S; Shave E; Vigh G
    J Chromatogr A; 2006 Oct; 1130(2):232-7. PubMed ID: 16626722
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Separation of human alloalbumin variants by isoelectric focusing.
    Rocha J; Kömpf J; Ferrand N; Amorim A; Ritter H
    Electrophoresis; 1991 Apr; 12(4):313-4. PubMed ID: 1906401
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Use of noncommercial carrier ampholytes for chromatofocusing.
    Just WW
    Methods Enzymol; 1983; 91():299-308. PubMed ID: 6855582
    [No Abstract]   [Full Text] [Related]  

  • 19. [Isofocusing of proteins in a tris-boro-polyol system in disc electrophoresis].
    Azhitskiĭ GIu; Troitskiĭ GV
    Lab Delo; 1981; (4):232-5. PubMed ID: 6164862
    [No Abstract]   [Full Text] [Related]  

  • 20. Isoelectric focusing on cellulose acetate membranes: an up-date on materials and methods.
    Ambler J
    Electrophoresis; 1989 Jul; 10(7):520-3. PubMed ID: 2476306
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.