21. Attenuation equalizing filter in diagnostic radiography. Advantages calculated by a Monte Carlo technique. Kusoffsky L; Carlsson CA; Edholm P Acta Radiol Ther Phys Biol; 1976 Jun; 15(3):259-72. PubMed ID: 970221 [TBL] [Abstract][Full Text] [Related]
22. The reduction in radiation dose for intra-oral radiographs by the use of thin K-edge filters. MacDonald-Jankowski DS; Lawinski CP Br J Radiol; 1991 Jun; 64(762):524-8. PubMed ID: 2070183 [TBL] [Abstract][Full Text] [Related]
23. The effect of thin K-edge filters on radiation dose in dental radiography. MacDonald-Jankowski DS; Lawinski CP Br J Radiol; 1992 Nov; 65(779):990-5. PubMed ID: 1450837 [TBL] [Abstract][Full Text] [Related]
24. Evaluation of Niobi-X filtration in intraoral radiology. White SC; Gratt BM Oral Surg Oral Med Oral Pathol; 1991 Dec; 72(6):746-55. PubMed ID: 1812457 [TBL] [Abstract][Full Text] [Related]
26. Evaluation of the use of a niobium filter for patient dose reduction in chest radiography. Thierens H; Kunnen M; Van der Plaetsen A; Segaert O Br J Radiol; 1991 Apr; 64(760):334-40. PubMed ID: 2025775 [TBL] [Abstract][Full Text] [Related]
27. Dose reduction in paediatric radiology using rare earth filtration. Fleay RF; Fox RA; Sprague PL; Adams JP Pediatr Radiol; 1984; 14(5):332-4. PubMed ID: 6472920 [TBL] [Abstract][Full Text] [Related]
28. Skin exposure and thyroid dose distribution using niobium filtration. Byrne CM; Pharoah MJ; Wood RE J Can Dent Assoc; 1991 Aug; 57(8):663-5. PubMed ID: 1889018 [TBL] [Abstract][Full Text] [Related]
29. A fit method for the determination of inherent filtration with diagnostic x-ray units. Meghzifene K; Aiginger H; Nowotny R Phys Med Biol; 2006 May; 51(10):2585-97. PubMed ID: 16675871 [TBL] [Abstract][Full Text] [Related]
31. Analogous filters for beam shaping in diagnostic radiology. Carrier R; Béïque RA Phys Med Biol; 1992 Jun; 37(6):1313-20. PubMed ID: 1626024 [TBL] [Abstract][Full Text] [Related]
32. Single-energy pediatric chest computed tomography with spectral filtration at 100 kVp: effects on radiation parameters and image quality. Bodelle B; Fischbach C; Booz C; Yel I; Frellesen C; Kaup M; Beeres M; Vogl TJ; Scholtz JE Pediatr Radiol; 2017 Jun; 47(7):831-837. PubMed ID: 28352977 [TBL] [Abstract][Full Text] [Related]
33. Clinical evaluation of a samarium compound filter and E-speed film. Mauriello SM; Overman VP; Mann GB Quintessence Int; 1996 Nov; 27(11):769-73. PubMed ID: 9161270 [TBL] [Abstract][Full Text] [Related]
34. Use of 3D adaptive raw-data filter in CT of the lung: effect on radiation dose reduction. Kubo T; Ohno Y; Gautam S; Lin PJ; Kauczor HU; Hatabu H; AJR Am J Roentgenol; 2008 Oct; 191(4):1071. PubMed ID: 18806144 [TBL] [Abstract][Full Text] [Related]