These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

97 related articles for article (PubMed ID: 725725)

  • 1. The relationship between suture number and quality of anastomoses in microvascular procedures.
    Robertson JH; Robertson JT
    Surg Neurol; 1978 Oct; 10(4):241-5. PubMed ID: 725725
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Application of fibrin glue in microvascular anastomoses: comparative analysis with the conventional suture technique using a free flap model.
    Cho AB; Júnior RM
    Microsurgery; 2008; 28(5):367-74. PubMed ID: 18561266
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [VCS microclip anastomosis on blood vessels of less than 2 millimeters in diameter. Preliminary experimental study in the rat].
    Gerbault O; Arrouvel C; Servant JM; Revol M; Banzet P
    Ann Chir Plast Esthet; 1998 Feb; 43(1):27-39. PubMed ID: 9768090
    [TBL] [Abstract][Full Text] [Related]  

  • 4. End-to-side and end-to-end vascular anastomoses with a carbon dioxide laser.
    Nakata S; Campbell CD; Pick R; Replogle RL
    J Thorac Cardiovasc Surg; 1989 Jul; 98(1):57-62. PubMed ID: 2739426
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Are mechanical microvascular anastomoses easier to learn than suture anastomoses?
    Zdolsek J; Ledin H; Lidman D
    Microsurgery; 2005; 25(8):596-8. PubMed ID: 16284953
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Termino-lateral anastomosis of the carotid of the rat. Histological evaluation of permeability in relation to the number of suture stitches and the thread used].
    Calvo A; Purriel JA
    Acta Neurol Latinoam; 1980; 26(4):215-22. PubMed ID: 6758468
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Use of continuous horizontal mattress suture techniques in microsurgery: an experimental study in rats.
    Tetik C; Unal MB; Kocaoglu B; Erol B
    J Hand Surg Am; 2005 May; 30(3):587-95. PubMed ID: 15925172
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [Experimental microsurgery on submillimetric vessels: technic and results (author's transl)].
    Ouaknine GE
    Neurochirurgie; 1980; 26(1):67-70. PubMed ID: 7442905
    [TBL] [Abstract][Full Text] [Related]  

  • 9. End-to-end versus end-to-side arterial anastomosis patency in microvascular surgery.
    Dotson RJ; Bishop AT; Wood MB; Schroeder A
    Microsurgery; 1998; 18(2):125-8. PubMed ID: 9674928
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [Comparative study of microvascular anastomotic clips and suture in small vessel anastomosis].
    Song JX; Guo ET
    Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2001 Sep; 15(5):312-4. PubMed ID: 11761863
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Histopathology of the arterial wall after animal experiment microsurgical operations].
    Tilgner A
    Z Exp Chir Transplant Kunstliche Organe; 1986; 19(2):100-12. PubMed ID: 3727655
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Experimental study of the reliability of end to end arterial microanastomosis].
    Cariou JL; Vergote T; Arrouvel C; Banzet P
    Ann Chir Plast Esthet; 1993 Oct; 38(5):599-611. PubMed ID: 7944236
    [TBL] [Abstract][Full Text] [Related]  

  • 13. End-to-end microvascular anastomosis in the rat carotid artery using continuous horizontal mattress sutures.
    Simşek T; Eroglu L; Engin MS; Kaplan S; Yildiz L
    J Reconstr Microsurg; 2006 Nov; 22(8):631-40. PubMed ID: 17136676
    [TBL] [Abstract][Full Text] [Related]  

  • 14. In search of the "perfect" anastomosis.
    Guity A; Young PH; Fischer VW
    Microsurgery; 1990; 11(1):5-11. PubMed ID: 2182965
    [TBL] [Abstract][Full Text] [Related]  

  • 15. In vivo evaluation of nylon suture material by the scanning electron microscope.
    Gregorius FK; Rand RW
    Surg Gynecol Obstet; 1976 Sep; 143(3):429-32. PubMed ID: 785639
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Microvenous grafts to arterial defects. The use of mechanical or suture anastomoses.
    Gilbert RW; Ragnarsson R; Berggren A; Ostrup L
    Arch Otolaryngol Head Neck Surg; 1989 Aug; 115(8):970-6. PubMed ID: 2751857
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Experimental laser-assisted end-to-side microvascular anastomosis.
    Sartorius CJ; Shapiro SA; Campbell RL; Klatte EC; Clark SA
    Microsurgery; 1986; 7(2):79-83. PubMed ID: 3724430
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Blood vessel sutures with absorbable suture material: roentgenological, hemodynamic, light and electron microscopy findings. I].
    Sandmann W; Staskiewicz W; Wildeshaus KH; Lenz W; Peronneau P
    Chir Forum Exp Klin Forsch; 1979; ():1-6. PubMed ID: 378582
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Comparative study of different combinations of microvascular anastomosis types in a rat vasospasm model: versatility of end-to-side venous anastomosis in free tissue transfer for extremity reconstruction.
    Miyamoto S; Takushima A; Okazaki M; Ohura N; Momosawa A; Harii K
    J Trauma; 2009 Mar; 66(3):831-4. PubMed ID: 19276761
    [TBL] [Abstract][Full Text] [Related]  

  • 20. End-to-side microvascular anastomosis using an external metal ring.
    Karamürsel S; Kayikçioğlu A; Safak T; Keçik A
    Br J Plast Surg; 2000 Jul; 53(5):423-6. PubMed ID: 10876283
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.